Maximum /
recommended
protection
Minimum
protection
CEILING
WALL
BEST IN THE
MIDDLE OF THE ROOM
Min. 1 m
Min.
15 cm
Max.
30 cm
90 cm
LIVING
ROOM
LANDING
KITCHEN
HALL-
WAY
BASEMENT
LIVING ROOM
BATHROOM
KITCHEN
BEDROOM
BEDROOM
BEDROOM
BEDROOM
HALLWAY
Maximum /
recommended
protection
Minimum
protection
CEILING
WALL
BEST IN THE
MIDDLE OF THE ROOM
Min. 1 m
Min.
15 cm
Max.
30 cm
BATHROOM
BEDROOM
LIVING
ROOM
LANDING
KITCHEN
TECHNICAL DATA
Power source 230 VAC
Battery backup
9Vbatterylonglifelithium
(included), operating time 1
month at 230V dropout.
Radio frequency 433 MHz (GNS-2236/RF2)
Range, clear line of sight up to 50 m (GNSP-2236/RF2)
Alarm signal 85 dB at 3 metres
Operating temperature 0°C – 40°C
Ambient humidity 0 – 90 %
Max. number linked 20 x wireless / 40 x wired
Maximum total cable
length
150 metres with wired
interconnection
Nexa's GNSP-2236 smoke alarm is designed to detect
smoke particles and can be interconnected as follows;
GNSP-2236/RF2canbeinterconnectedwirelesslywith
GNS-2236/RF2, MTS-166/RF2 and MTS-163/RF2,
as well as through wires with GNS-2236/RF2, GNS-
2236/10Y and GNSP-2236/10Y.
GNSP-2236/10Y can be interconnected through wires with
GNS-2236/10Y, GNS-2236/RF2 and GNSP-2236/RF2.
PRIMARY FEATURES:
Opticalsensortodetectsmoulderingres
• LEDindicationforoperationandalarm
• Wirelessandwiredconnection
• Batterybackup
• Signalforlowbatteryvoltage
• Silentfunction
• Dustguardincluded
IMPORTANT
• Theradiorangemayvarydependingonthelocation,
the design of the building and the materials used in the
building.
• Donotremoveordisconnectthebatteriestostopfalse
alarms as this will disable the vital function of the smoke
alarm.Openwindowsorventilatetheairaroundthe
smoke alarm in order to stop it, and/or press the pause
button.
• Thesmokealarmisintendedforuseforuseinsingle-
familyhomes.Inmultiple-occupancybuildings,each
home must be equipped with its own smoke alarms.
• Thissmokealarmisnotsuitableforuseinbuildingsthat
are not used for residential purposes. The smoke alarm
isnosubstituteforafullalarmsystemthatisrequired
bylaworbythereauthorities.
• Thesmokealarmdetectscombustionparticlesintheair
(smoke).Itdoesnotreacttoamesorgas.
• Thesmokealarmisdesignedtoemitanalarmsignalifa
reisdeveloping.
• Thesmokealarmshouldbetestedeveryweekand
replacedeverytenyears.
POSITIONING THE SMOKE ALARM
Forthesmokealarmtoprovideanearlywarning,ithastobe
installedinthelocationwheretherestarts.Therefore,Nexa
recommendsthatyouinstallsmokealarmsineachroomandon
alloors.
Single-level home: To achieve minimum protection,
position the alarm in the entrance hall between the living
areas (including the kitchen) and the sleeping areas.
Position it as close as possible to the living areas, and
makesurethealarmcanbeheardbyanyoneinthe
bedrooms. See Figure 1, for example:
Multi-storey home: To achieve minimum protection, position
and alarm in the stairwell (at ground level) and another alarm
abovethelandingonthetopoor,aswellasanalarmonthe
ceiling in the basement at the foot of the stairs. This covers the
basement level, but not crawl spaces and unfurnished attics.
See the example in Figure 2.
Ceiling installation
Hotsmokerisesandspreads,soinstallingyoursmokealarm
in a central location on the ceiling is recommended. Avoid
areas where air does not circulate, e.g. corners. Also keep
itawayfromobjectsthatmaypreventthefreeowofair.
Positionthedeviceatleast30cmfromlightttingsorinterior
ttingsthatmaypreventsmoke/heatreachingthedetector.
Positionitatleast1metreawayfromthewall.SeeFigure3A.
Wall mounting, if ceiling mounting is not possible
Avoidinstallingthedevicealongwayintoacorner.
Position the upper edge of the smoke alarm at least 15 cm and
nomorethan30cmawayfromtheceiling.SeeFigure3A.
Sloping ceilings
In the case of sloping surfaces or ceilings that move up
towards a ridge, the detector must be installed 90 cm from the
highestpoint,measuredhorizontally,becausestillairunderthe
ridgemaypreventsmokereachingthedevice.SeeFigure3B.
NOTE: There must be an alarm in every room (except the
kitchen, bathroom and garage) to provide recommended/
maximum protection. DO NOT POSITION AN ALARM IN
THE KITCHEN or BATHROOM as cooking smells or steam
may activate the alarm. DO NOT POSITION AN ALARM
IN THE GARAGE as there is a risk of it being triggered by
exhaust fumes.
INSTALLATION
Thesmokealarmmustbeinstalledbyaqualied
electrician in accordance with the relevant regulations
for electrical installations. The smoke alarm must have
anuninterruptablepowersupplywhichcannotbe
turnedobymistake.
Allsmokealarmsthatarelinkedbywiremustbepowered
from a single source with a common zero conductor.
Note: Do not connect wire for interconnection to Phase- or
Zero conductor. Disconnect from the power supply that is
to be used.
If no recessed junction box is available, t
suitable junction box adjacent to the smoke alarm's
position. Ensure that there are no other electric wires in
the immediate vicinity of the smoke alarm.
• Useascrewdrivertoreleasethesmokealarmfromthe
mounting plate with connection terminal. See gure 4
• Fitthemountingplateinselectedlocationand
connectwires(Live=Phase,Neutral=Zero)
for current as well as wired interconnection
(Interconnect) if used.
• Protectiveearthdoesnotneedtobeconnectedto
thesmokealarm,theyellow/greenwireisconnected
tosupportterminalmarkedwithearthsymbolfor
relay.See Figures 5 & 6.
• Cablearea.Forvoltagefeed1.5mm2, for
interconnection 0.22 mm2 or more.
• Insert9Vbattery(supplied)inthebatterycompartment
onthesmokealarm'sunderside-Notethepolarity.
Forsafetyreasons,thesmokealarmcannotbetted
onthemountingplatewithouta9Vbattery.
• Beforethesmokealarmisttedonthemounting
plate, a function test must be performed (with power
supplyfrom9Vbattery)bypressinginthetestbutton
on the smoke alarm, which should then emit a load
pulsating signal. See gure 7.
• Beforettingthesmokealarmonthemountingplate,itis
alsoadvisabletocarryoutprogrammingofthewireless
interconnection–seethePROGRAMMINGsection.
• Fitthesmokealarmonthemountingplatebysliding
it into place in the direction of the arrows.
• Turnonthecurrentandthentestthatthesmoke
alarmisfunctioningbypressinginthetestbutton.
See gure 7.
• Withnewconstructionorrefurbishment,leavethe
dustguardonthesmokealarmuntilnalcleaningis
completed.
OPTICALSMOKEALARM230V
FORCONNECTIONINSERIES
Model: GNSP-2236/RF2 and
GNSP-2236/10Y
This instruction folder contains important information
on correct installation and maintenance of your
smoke alarm. Read through the whole folder before
installing it, and keep the folder for future reference.
Figure 4. Press the catch upwards and simultaneously
pull the smoke alarm sideways to release it from the
mounting plate
Figure 1. Single-level home
Figure 2. Multi-storey home
LOCATION ON CEILING AND WALL
Figure 3BFigure 3A