EXHAUSTO DTV Version 2 Bruksanvisningar

Typ
Bruksanvisningar
EXHAUSTO A/S
Odensevej 76
DK-5550 Langeskov
Tel. +45 65 66 12 34
Fax +45 65 66 11 10
www.exhausto.dk
DTV 3006656-2023-09-27.fm
DTV Version 2
-TGK
DTV 3006656-2023-09-27.fm
2/56
1. GB - Product information
1.1 Construction and design...................................................................................................................5
2. GB - Fitting
2.1 Transport safety fitting DTV315, DTV400 and DTV450...................................................................6
2.2 TGK roof duct.....................................................................................................................................6
2.3 Installing a fan onto a TGK roof duct...............................................................................................8
2.4 Installing a fan onto a roof base using an FPT base plate.............................................................8
3. GB - Wiring
3.1 Fan without EC control......................................................................................................................9
3.1.1 DTV160-4-1 & DTV200-4-1 .......................................................................................................9
3.2 Fan with EC control .........................................................................................................................10
3.2.1 DTV250-4-1EC2, DTV315-4-1EC2, DTV400-4-1EC2 & DTV450-4-1EC2 ..............................10
3.2.3 Troubleshooting DV-EC controls..............................................................................................12
4. GB - Service and cleaning
4.1 Cleaning............................................................................................................................................13
4.2 Environmental declaration..............................................................................................................14
1. DK - Produktinformation
1.1 Konstruktion.....................................................................................................................................15
2. DK - Montage
2.1 Transportsikring DTV315, DTV400 og DTV450 .............................................................................16
2.2 Taggennemføring TGK....................................................................................................................16
2.3 Montage på taggennemføring TGK................................................................................................18
2.4 Montage på tagsokkel via fodplade FPT........................................................................................18
3. DK - El-tilslutning
3.1 Ventilatorer uden EC-styring ..........................................................................................................19
3.2.1 DTV160-4-1 & DTV200-4-1 .....................................................................................................19
3.2 Ventilatorer med EC-styring ...........................................................................................................20
3.2.2 DTV250-4-1EC2, DTV315-4-1EC2, DTV400-4-1EC2 & DTV450-4-1EC2 ..............................20
3.2.1 Fejlfinding for DV-EC-styring....................................................................................................22
4. DK - Service og rengøring
4.1 Rengøring.........................................................................................................................................23
3.2 Miljødeklaration................................................................................................................................24
DTV 3006656-2023-09-27.fm
3/56
1. DE - Produktinformation
1.1 Konstruktion.....................................................................................................................................25
2. DE - Montage
2.1 Transportsicherung DTV315, DTV400 und DTV450......................................................................26
2.2 Dachdurchführung TGK..................................................................................................................26
2.3 Montage auf der Dachdurchführung TGK .....................................................................................28
2.4 Montage auf Dachsockel über Fußplatte FPT...............................................................................28
3. DE - Elektrischer Anschluss
3.1 Ventilatoren ohne EC-Automatik....................................................................................................29
3.2.1 DTV160-4-1 & DTV200-4-1 .....................................................................................................29
3.2 Ventilatoren mit EC-Automatik.......................................................................................................30
3.2.2 DTV250-4-1EC2, DTV315-4-1EC2, DTV400-4-1EC2 & DTV450-4-1EC2 ..............................30
3.2.1 Fehlersuche bei DV-EC-Automatik ..........................................................................................32
4. DE - Wartung und Reinigung
4.1 Reinigung .........................................................................................................................................33
3.2 Umweltdeklaration...........................................................................................................................34
1. NO - Produktinformasjon
1.1 Konstruksjon....................................................................................................................................35
2. NO - Montering
2.1 Transportsikring DTV315, DTV400 og DTV450 .............................................................................36
2.2 Takgjennomføring TGK...................................................................................................................36
2.3 Montering på takgjennomføring TGK ............................................................................................38
2.4 Montering på taksokkel via fotplate FPT .......................................................................................38
3. NO - Elektrisk tilkobling
3.1 Vifter uten EC-styring......................................................................................................................39
3.1.1 DTV160-4-1 & DTV200-4-1 .....................................................................................................39
3.2 Vifter med EC-styring ......................................................................................................................40
3.2.1 DTV250-4-1EC2, DTV315-4-1EC2, DTV400-4-1EC2 & DTV450-4-1EC2 ..............................40
3.2.1 Feilsøking for DV-EC-styring....................................................................................................42
4. NO - Service og rengjøring
3.1 Rengjøring........................................................................................................................................43
3.2 Miljødeklarasjon...............................................................................................................................44
DTV 3006656-2023-09-27.fm
4/56
1. SE - Produktinformation
1.1 Konstruktion.....................................................................................................................................45
2. SE - Montering
2.1 Transportsäkring DTV315, DTV400 och DTV450 ..........................................................................46
2.2 Takgenomföring TGK ......................................................................................................................46
2.3 Montering på takgenomföring TGK................................................................................................48
2.4 Montering på taksockel via fotstöd FPT........................................................................................48
3. SE - Elanslutning
3.1 Fläktar utan EC-styrning .................................................................................................................49
3.1.1 DTV160-4-1 & DTV200-4-1 .....................................................................................................49
3.2 Fläktar med EC-styrning .................................................................................................................50
3.2.1 DTV250-4-1EC2, DTV315-4-1EC2, DTV400-4-1EC2 & DTV450-4-1EC2 ..............................50
3.2.1 Felsökning för DV-EC-styrning ................................................................................................52
4. SE - Service och rengöring
3.1 Rengöring.........................................................................................................................................53
3.2 Miljödeklaration................................................................................................................................54
DTV 3006656-2023-09-27.fm GB - Product information
5/56
1.GB - Product information
EXHAUSTO DTV roof fans are used in air supply and extraction systems.
The ventilator is not to be used to transport solid particles, nor in areas
where there is a risk of explosive gases.
The ventilator must not be started with the Top section open.
Description EXHAUSTO DTV vertical discharge roof fans are available in the following single-phase
motor models (EC types have built-in EC control:
• DTV160-4-1
• DTV200-4-1
• DTV250-4-1EC2
• DTV315-4-1EC2
• DTV400-4-1EC2
• DTV450-4-1EC2
The roof fan is made of corrosion-resistant aluminium. To protect fingers and avoid birds
getting trapped in the fan box, it is fitted with a rustproof safety net.
Main components
Size and weight
1.1 Construction and design
Pos. Part
a Top section
b Bottom section
c Motor
d Centrifugal impeller
e Centrifugal impeller inlet
f Safety fittings
g Net
h Handle
i Connecting cable
j Rubber ring seal between the fan and duct/base plate
k Vibration dampers ensure vibration-free operation
l EC regulator
m Safety screws (yellow)
n Top section cover
Q
5'
L
O
j, k and m, see section 2.3
DTV 160 200 250 315 400 450
Weight, kg 11 17 28 37 52 60
DTV 3006656-2023-09-27.fm GB - Fitting
6/56
2.GB - Fitting
Before installation
Remove the transport safety fitting by the centrifugal impeller (can be done without
having to open the fan) and check that the impeller turns freely.
Construction EXHAUSTO standard TGK roof ducts are made of
galvanised plate casing, with 50 mm mineral wool for
insulation/sound absorption and fibreglass and has an
internal galvanised perforated plate.
The roof duct has an inner cable conduit, through which
the isolation switch cabling and the cabling can be pulled
all the way through.
The roof duct is delivered with anti-backdraught shutters
AOR.
Installing the
isolation switch
Fit the isolation switch (not supplied by EXHAUSTO) on the TGK roof duct directly onto
the seal. The fan's connecting cable is fed in from the bottom through the threaded cable
entry.
Duct system and
extraction system
The roof duct can be connected to any EUROVENT-
standard duct system.
2.1 Transport safety fitting DTV315, DTV400 and DTV450
RD13628-01
2.2 TGK roof duct
RD12887-01
RD12889-02
DTV 3006656-2023-09-27.fm GB - Fitting
7/56
Installing TGK roof ducts
Step Action
1 Make a hole in the roof, approx. 30 mm larger than the roof duct.
2 Loosen the overlying tile/roofing and push it up to make room for the cover.
PERFORM or lead cover Zinc cover
NB:
applies only to
PERFORM
It is a good idea to bend the edge of the
flashing (at the bottom and if appropriate, the
visible part of the sides) to ensure greater
strength/better form stability and a nicer finish.
See the pictures above.
3 Fit the roof duct carefully into the roof so the
cover is flush with the top of the tiles.
Fit the roof duct carefully into the roof so the
cover is flush with the roofing material.
4 Fit the support bars to the roof duct, so that
the roof duct will be lifted approx. 5 mm when
the support bars have been attached to the
roofing beams. This ensures that all the
weight is taken by the support bars.
Fit the support bars to the roof duct, so that
the roof duct will be lifted approx. 1 mm when
the support bars have been attached to the
roofing beams. This ensures that all the
weight is taken by the support bars.
5 Roll out the cover material and knock it gently
into shape with a rubber hammer or sandbag.
6If water travels from copper or bitumen onto
PERFORM, FlashSeal must be applied to the
PERFORM surface.
If you do not follow the instructions, the war-
ranty becomes void!
7 Replace the overlying tile/roofing over the cover.
DTV 3006656-2023-09-27.fm GB - Fitting
8/56
The fan can be mounted directly onto the EXHAUSTO standard TGK roof duct
NB The air being extracted can contain water vapour and cause condensation, so the
roof base must be insulated.
2.3 Installing a fan onto a TGK roof duct
3-01
Step Action
1 Tighten securely the provided four vibration dampers (k) in the threaded
holes in the roof duct.
2 Place the rubber ring (j) between the duct and the centrifugal impeller inlet.
3 Secure the roof fan onto the vibration dampers with the nuts.
4 Tighten the two yellow safety screws (m) in the roof duct via the free holes in
the bottom section. The screws ensure the DTV remains attached to the roof
duct in all situations.
RD12884-01
2.4 Installing a fan onto a roof base using an FPT base plate
RD12124-01
Step Action
1 Fasten the base plate onto the roof base.
2 Seal the base plate and roof base joint using a joint sealing compound.
3 Tighten securely the four vibration dampers provided (k) in the threaded
holes in the base plate.
4 Place the rubber ring (j) between the duct and the centrifugal impeller inlet.
5 Secure the roof fan onto the vibration dampers with the nuts.
6 Tighten the two yellow safety screws (m) in the base plate via the free holes
in the bottom section. The screws ensure the DTV remains attached to the
base plate in all situations.
RD12885-01
DTV 3006656-2023-09-27.fm GB - Wiring
9/56
3.GB - Wiring
General
The wiring must only be done by a qualified electrician.
The fan and motor specifications are listed on the type-plates.
Max. fuse rating = 13 Amp.
Max. short circuit current is 10 kA
At start-up and during the initial adjustment of the fan, it is important to control the
direction of rotation of the motor and to check the motor current does not exceed the
manufacturer’s recommended operating current for the motor (to avoid damaging the
motor).
Isolation switch EXHAUSTO A/S would like to draw attention to the fact that, in
accordance with the EU's Machine Directive (appendix 1) all fan
systems shall include a isolation switch.
The isolation switch must ...
be lockable or positioned in plain sight in the immediate vicinity of the fan
be able to disconnect all poles from the supply voltage
— contact distance of at least 3 mm in each pole
Set up as isolation switch in accordance with standard IEC 60947-1 or
IEC 60947-3.
The isolation switch is not supplied by EXHAUSTO.
Lightning
conductor
Any lightning conductor connected to the fan must be in accordance with applicable
regulations and legislation.
3.1.1 DTV160-4-1 & DTV200-4-1
Wiring
All single-phase fans are voltage regulated.
The motor is fitted with a thermal cut-out. The thermal-cut out is factory installed, wired
in series to the motor's power circuit.
If the fuse is a ...it must have the characteristic
melting fuse gG or gM.
control fuse B or C, and comply with IEC 90947-2. -
3.1 Fan without EC control
Wiring — cable from the motor
Single-phase motor with built-in thermal
cut-out
DTV160-4-1, DTV200-4-1
Brown = L
Blue = N
Yellow/Green =
DTV 3006656-2023-09-27.fm GB - Wiring
10/56
General Fans marked EC have a built-in EC control.
Cables The wiring for control signal inputs must be completely insulated from the supply wirings.
ESD
The electrician must be ESD protected when
detaching the cover on the EC control
working with the EC control
3.2.1 DTV250-4-1EC2, DTV315-4-1EC2, DTV400-4-1EC2 & DTV450-4-1EC2
Cable type Cables for control signals must be with twisted pair conductors. As a minimum, the cable
type must be CAT5e Ethernet cable.
Diagram
3.2 Fan with EC control
DTV 3006656-2023-09-27.fm GB - Wiring
11/56
Key to diagram
Leakage current The EC control produces a leakage current when running. The leakage current must be
earthed, as there is a risk of the motor becoming live.
A leakage current of up to 150 mA can be generated.
To comply with EN50178, the fan must be suitably earthed.
Earth leak circuit
breakers
If current earth leak circuit breakers are fitted in the installation, they must be of
a type that meets the following requirements:
PFI type B breaker according to EN 61008, that breaks the circuit when a
vagrant current with DC content (pulsating DC) or smooth vagrant current
is registered.
The circuit breakers must be marked with the following symbols:
Terminal Signal description Comments
1RS485 + (A)
2RS485 - (B)
3 0 V DC (chassis)
4 10 V DC EFC1P/EFC1P2 panel 5
5 0-10 V DC EFC1P/EFC1P2 panel 4
6 0 V DC (chassis) EFC1P/EFC1P2 panel 3
7
8 Start/stop EFC1P/EFC1P2 panel 2
9
10 0 V DC (chassis)
11 Run NC
12 Run C
13 Run NO
14 Alarm NC
15 Alarm C EFC1P/EFC1P2 panel B
16 Alarm NO EFC1P/EFC1P2 panel A
DTV 3006656-2023-09-27.fm GB - Wiring
12/56
3.2.2 Troubleshooting DV-EC controls
DV-EC-control
LED indicator The DV-EC control is equipped with a two-coloured green and red LED indicator
of the different operating modes.
The LED is located on the underside of the control unit next to the cable entry for
the main voltage connection.
Troubleshooting
chart
Steady green when main voltage is connected.
Flashes green when Modbus communication is active.
Steady red for at least one critical alarm.
Flashes red for at least one non-critical alarm.
LED error indicator:
1 flash = Supply problem
3 flashes = Internal DV problem
5 flashes = motor problem
Accessory As an accessory you can buy a hand-held terminal for operation and alarm info.
DTV 3006656-2023-09-27.fm GB - Service and cleaning
13/56
4.GB - Service and cleaning
EXHAUSTO DTV roof fan motors have special ball bearings that are sealed, lubricated
and maintenance-free. Any replacement of these bearings should be carried out by
technicians from EXHAUSTO SERVICE.
The fan and duct system should be cleaned as necessary, depending on dirt levels, in
the following manner:
4.1 Cleaning
Step Action
1 Shut down the fan using the isolation switch
2 Loosen the screws on the front of the fan and swing the top section
up by the handle. The safety fitting will ensure the top section stays
up as you clean.
3 Brush the centrifugal impeller.
Wash the impeller with soapy water if needed. Be very careful to
avoid water getting into the duct system or into the motor.
4 The roof duct and duct system:
Remove the impeller-insert (e) and if necessary the anti-backdraught
AOR. The roof duct and the duct system can now be cleaned down
inside and around the opened fan.
NB: Cleaning of the duct system must be done carefully, in such a
fashion as to avoid any dirt or dust getting into the fan's operating
parts.
DTV 3006656-2023-09-27.fm GB - Service and cleaning
14/56
Product
description
EXHAUSTO DTV is a an easily serviced radial fan with backward curved blades. The
fan impeller is directly mounted on the motor shaft, thus reducing losses and wear and
resulting in lower repair costs.
Service and cleaning is done by opening the hinged cover. This provides access to all
parts in contact with the air.
The motor and any motor controls are mounted outside the air flow. The fan is CE
approved and EMC tested in accordance with the applicable directives.
Materials used The fan housing and the fan impellers are made of recyclable pressure-cast aluminium.
The visible parts of the fan housing are painted with water-based paint.
The motor consists of aluminium, steel and copper, and in some cases a plastic cooling
jacket. The packaging consists of corrugated cardboard.
Materials in %
4.2 Environmental declaration
DTV160 DTV200 DTV250EC2 DTV315EC2 DTV400EC2 DTV450EC2
Aluminium 75% 79% 72% 76% 75% 72%
Fe 17% 15% 16% 15% 19% 22%
Copper 4% 3% 2% 1% 2% 2%
PCB;
electronic
components
1% 1% 7% 5% 2% 2%
Plastic,
cellular rubber
1% 1% 1% 1% 1% 1%
Other 2% 1% 2% 2% 1% 1%
DTV 3006656-2023-09-27.fm DK - Produktinformation
15/56
1.DK - Produktinformation
EXHAUSTO tagventilator DTV anvendest i indblæsnings- og udsugningsanlæg.
Ventilatoren må ikke anvendes til transport af faste partikler, eller hvor
der er risiko for eksplosive gasarter.
Ventilatoren må ikke startes med åben toppart.
Beskrivelse EXHAUSTO tagventilator DTV har vertikalt afkast og fås i følgende 1-fasede
motorvarianter (EC er betegnelsen for EC motorer med indbygget EC-styring):
• DTV160-4-1
• DTV200-4-1
• DTV250-4-1EC2
• DTV315-4-1EC2
• DTV400-4-1EC2
• DTV450-4-1EC2
Tagventilatoren er af korrosionsbestandigt aluminium. Der er monteret rustfrit net som
finger- og fuglebeskyttelse.
Hovedkomponenter
Størrelse og vægt
1.1 Konstruktion
Pos. Del
a Toppart
b Bundpart
c Motor
d Centrifugalhjul
e Centrifugalindsats
f Sikringsbeslag
g Net
h Håndtag
i Tilslutningskabel
j Gummiring. Tætner mellem ventilator og taggennemføring/fodplade.
k Svingningsdæmpere. Sikrer vibrationsfri drift.
l EC-regulator
m Sikkerhedsskruer (gule)
n Topdæksel
5'
j, k og m, se afsnit 2.3
DTV 160 200 250 315 400 450
Vægt - kg 11 17 28 37 52 60
DTV 3006656-2023-09-27.fm DK - Montage
16/56
2.DK - Montage
Inden montage
Fjern transportsikringen ved centrifugalhjulet (kan gøres uden at åbne ventilatoren) og
kontroller at hjulet kan løbe uhindret rundt.
Beskrivelse EXHAUSTO standard taggennemføring TGK er
opbygget af et galvaniseret pladesvøb, 50 mm
mineraluld for isolering/ lyddæmpning, glasvæv
og indvendigt en galvaniseret perforeret plade.
Taggennemføringen er forsynet med en
indvendig kabelkanal, hvor installationskablet til
forsyningsadskilleren trækkes igennem.
Taggennemføringen leveres med
overtryksspjæld AOR.
Monter
forsyningsadskiller
Monter forsyningsadskilleren (ikke EXHAUSTO leverance) på taggennemføringen TGK
direkte imod pakningen. Ventilatorens tilslutningskabel føres ind i forsyningsadskilleren
nedefra gennem kabelforskruning.
Kanalsystem og
udsugnings-
amatur
Taggennemføringen kan i bunden tilsluttes
ethvert kanalsystem med standardmål i
henhold til EUROVENT (nippelmål).
2.1 Transportsikring DTV315, DTV400 og DTV450
RD13628-01
2.2 Taggennemføring TGK
RD12887-01
RD12889-02
DTV 3006656-2023-09-27.fm DK - Montage
17/56
Sådan monteres taggennemføringen TGK
Trin Handling
1 Der laves et hul i taget, ca. 30 mm større end taggennemføringen.
2 Overliggende tagsten/-plade løsnes og forskydes opad a.h.t. inddækningen.
PERFORM-inddækning Zinkinddækning
BEMÆRK
- gælder kun
PERFORM
Kanten af inddækningen (nederst, samt evt.
den synlige del af siderne) kan med fordel
ombukkes. Herved opnås større styrke (bedre
formstabilitet og en pænere finish (se
ovenstående fotos.).
3 Taggennemføringen placeres forsigtigt i taget,
således at inddækningen ligger plant med
toppen af tagpladerne.
Taggennemføringen placeres forsigtigt i taget,
således at inddækningen ligger plant med
tagmaterialet.
4 Bærejernene fastgøres til taggennemføringen,
således at den løftes ca. 5 mm, når
bærejernene efterfølgende fastgøres til
tagspærene. Herved sikres at hele vægten
ligger på bærejernene.
Bærejernene fastgøres til taggennemføringen,
således at den løftes ca. 1 mm, når
bærejernene efterfølgende fastgøres til
tagspærene. Herved sikres at hele vægten
ligger på bærejernene.
5 Inddækningsmaterialet rulles ud og bankes
forsigtigt i form med en gummihammer eller
sandpose.
6 Sker der afvanding fra kobber eller bitumen
(tagpap) til PERFORM, skal PERFORM’s
overflade påføres FlashSeal. Følges
anvisningerne ikke, bortfalder garantien!
7 Overliggende tagsten/-plade lægges på plads over inddækningen.
DTV 3006656-2023-09-27.fm DK - Montage
18/56
Ventilatoren kan monteres direkte på EXHAUSTO standard taggennemføring TGK.
Bemærk Ved fugtig udsugningsluft kan der forekomme kondensvand, og tagsoklen skal
derfor altid isoleres.
2.3 Montage på taggennemføring TGK
3-01
Trin Handling
1 Spænd de 4 medleverede svingningsdæmpere (k) fast i gevindhullerne i
taggennemføringen.
2 Læg gummiringen (j) udvendigt om kanten på centrifugalindsatsen.
3 Fastspænd tagventilatoren på svingningsdæmperne med møtrikkerne.
4 Spænd de to gule sikkerhedsskruer (m) i taggennemføringen gennem
frihuller i bundparten. Skruerne sikrer, at DTV’en fastholdes på
taggennemføringen i alle situationer.
2.4 Montage på tagsokkel via fodplade FPT
RD12124-01
Trin Handling
1 Fastgør fodpladen til tagsoklen.
2 Forsegl samlingen mellem fodplade og tagsokkel med fugemasse.
3 Spænd de 4 medleverede svingningsdæmpere (k) fast i gevindhullerne i
fodpladen.
4 Læg gummiringen (j) udvendigt om kanten på centrifugalindsatsen.
5 Fastspænd tagventilatoren på svingningsdæmperne med møtrikkerne.
6 Spænd de to gule sikkerhedsskruer (m) i fodpladen gennem frihuller i
bundparten. Skruerne sikrer, at DTV’en fastholdes fodpladen i alle situationer.
DTV 3006656-2023-09-27.fm DK - El-tilslutning
19/56
3.DK - El-tilslutning
Generelt
El-installationen skal foretages af autoriseret el-installatør.
Ventilator- og motorspecifikationer fremgår af de monterede typeskilte.
Max. forsikring = 13 Amp.
Max. kortslutningsstrøm er 10 kA
Ved opstart og indregulering af ventilationsanlægget er det vigtigt at kontrollere
motorens omløbsretning, og at strømforbruget ikke overstiger mærkestrømmen på
typeskiltet, da det vil medføre overbelastning af motoren.
Forsyningsadskiller EXHAUSTO A/S gør opmærksom på, at der i henhold til
Maskindirektivet (bilag 1) skal opsættes en forsyningsadskiller i den
faste installation af ventilatoren.
Forsyningsadskilleren skal...
være aflåselig, eller placeres synligt i nærheden af ventilatoren.
kunne afbryde alle poler fra forsyningsspændingen
- kontaktafstand min. 3 mm i hver pol.
udføres som forsyningsadskiller i hht. IEC 60947-1 eller IEC 60947-3
Forsyningsadskilleren er ikke en del af EXHAUSTO’s leverance.
Lynafledning... ...skal ske i henhold til gældende love og bestemmelser.
3.1.1 DTV160-4-1 & DTV200-4-1
El-tilslutning
Alle 1-fasede ventilatorer er spændingsregulerbare.
Motoren er forsynet med termosikring. Termosikringen er fra fabrikken koblet i serie
med motorens strømkreds.
Hvis forsikringen er en ...skal den være med karakteristik
smeltesikring gG eller gM.
automatsikring B eller C, og opfylde IEC 90947-2.
3.1 Ventilatorer uden EC-styring
El-tilslutning - kabel fra motor
1-fasemotor med indbygget termosikring
DTV160-4-1, DTV200-4-1
Brun= L
Blå= Nreg.
Gul/Grøn=
DTV 3006656-2023-09-27.fm DK - El-tilslutning
20/56
Generelt Alle ventilatorer med typebetegnelsen "EC" er regulerbare via den indbyggede EC-
styring.
Kabler De ledninger, der skal tilsluttes styresignal-indgangene, skal i hele deres længde have
en forstærket isolering i forhold til forsyningsnettet.
ESD Elektrikeren skal være ESD-beskyttet:
når låget på EC-styringen demonteres
under arbejdet med EC-styringen
3.2.1 DTV250-4-1EC, DTV315-4-1EC & DTV400-4-1EC2
Kabeltype Kabler til styresignaler skal være med parsnoede ledere. Kabeltypen skal minimum
være CAT5e Ethernet kabel.
Diagram
3.2 Ventilatorer med EC-styring
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

EXHAUSTO DTV Version 2 Bruksanvisningar

Typ
Bruksanvisningar