Instructions for installation and use p. 6/26
2.2. Safety information for the installer
●Installing and connecting the sauna heater may only be performed
when the power supply is disconnected.
●Installationmayonlybeperformedbyaqualiedelectricianor
similarlyqualiedperson.
●A fully disconnecting all-pole isolating device compliant with
overvoltagecategoryIIImustbettedonsite.
●Always use silicone cables that are heat-resistant up to 150 °C
to connect the sauna heater.
●Only install one sauna heater in the cabin. The Concept R mini
sauna heater must not be used together with other sauna heaters
in a sauna cabin.
●The roof and walls of the sauna cabin must be manufactured
from low-resin, untreated or thermally treated wood, e.g. Nordic
spruce,hemlock,pineorr,orfromlaminatedwoodenmateri-
als. If laminated wooden materials are used, make sure that the
adhesiveusedinthemdoesnotgiveoformaldehyde.Ifother
materials than wood are used in the sauna cabin, these materi-
als must be heat-resistant and corrosion-resistant and must not
causeanynegativeeectsonthehealthofthesaunausers.
●The height of the sauna cabin must be at least 1.9 m.
● Observethespecicationsonvolumesandonventilationofthe
sauna cabin in chapter 11. Technical data.
●When positioning the sauna heater, observe the minimum safety
distances (see chapter 4.2. Safety distances).
●Also comply with the regulations applicable at the installation
location.
●For your own safety, consult your supplier in the event of prob-
lemsthatarenotexplainedinsucientdetailintheinstallation
instructions.