Champion CPG2500 Användarmanual

Kategori
Kraftgeneratorer
Typ
Användarmanual
This manual covers the following models:
CPG2500 (EU/SC) / CPG3500 (EU/SC)
CPG4000 E1 (EU/SC)
CPG6500 E2 (EU/SC) / CPG 9000 E2 (EU/SC)
OWNER’S MANUAL & OPERATING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Important Safety Instructions
are included in this manual.
PORTABLE
GENERATOR
Frame Type
T
h
r
e
e
Y
e
a
r
L
i
m
i
t
e
d
W
a
r
r
a
n
t
y
G
a
r
a
n
t
í
a
l
i
m
i
t
a
d
a
d
e
t
r
e
s
a
ñ
o
s
T
h
r
e
e
Y
e
a
r
L
i
m
i
t
e
d
W
a
r
r
a
n
t
y
G
a
r
a
n
t
í
a
l
i
m
i
t
a
d
a
d
e
t
r
e
s
a
ñ
o
s
ENGLISH
SVENSKA
NORSK
DEUTSCH
SUOMEN KIELI
2
INTRODUCTION
Record the model and serial numbers as well as date and place of purchase for future reference. Have this
information available when ordering parts and when making technical or warranty inquiries.
Champion Power Equipment Support
Model Number
Serial Number
Date of Purchase
Purchase Location
For Oil Type see ‘Add Engine Oil‘ section. For Fuel Type see ‘Add Fuel‘ section.
Introduction
Congratulations on purchasing your generator. Please
follow these instructions and maintain it correctly.
Portable Power Generator
This unit is a petrol engine driven AC generator used for
supply electrical power.
Accessories
CPE manufactures and supplies a series of accessories.
See local dealer for more information.
This Booklet
We reserve the right to change, alter or improve the
product and this manual without prior notice.
3
MANUAL CONVENTIONS
Please familiarize yourself with the following symbols. The safety symbol and key words are safety warnings. Follow all
safety messages to avoid accidents or injury.
CAUTION indicates a potentially hazardous
situation which, if not avoided, may result in minor
or moderate injury.
CAUTION
CAUTION used without the safety alert symbol
indicates a potentially hazardous situation which, if
not avoided, may result in property damage.
CAUTION
DANGER indicates an imminently hazardous
situation which, if not avoided, will result in death
or serious injury.
DANGER
WARNING indicates a potentially hazardous
situation which, if not avoided, could result in
death or serious injury.
WARNING
If you have questions regarding your generator, we can
help. Please contact yor local dealer.
NOTE
EN
4
SAFETY RULES
Generator exhaust contains carbon monoxide, a
colorless, odorless, poison gas. Breathing carbon
monoxide will cause nausea, dizziness, fainting or
death. If you start to feel dizzy or weak, get to fresh
air immediately.
Operate generator outdoors only in a well ventilated
area.
DO NOT operate the generator inside any building,
including garages, basements, crawlspaces and
sheds, enclosure or compartment, including the
generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confi ned
area through windows, doors, vents or other
openings.
DANGER CARBON MONOXIDE: using a generator
indoors CAN KILL YOU IN MINUTES.
DANGER
Rotating parts can entangle hands, feet, hair,
clothing and/or accessories.
Traumatic amputation or severe laceration can result.
Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
Operate equipment with guards in place.
DO NOT wear loose-fi tting clothing, dangling
drawstrings or items that could become caught.
DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or receptacles.
DO NOT use electrical cords that are worn, damaged
or frayed.
DO NOT operate generator in wet weather.
DO NOT allow children or unqualifi ed persons to
operate or service the generator
Use a ground fault circuit interrupter (GFCI) in damp
areas and areas containing conductive material such
as metal decking.
Use approved transfer equipment to isolate generator
from your electric utility and Notify your utility
company before connecting your generator to your
power system.
DANGER
Sparks can result in fi re or electrical shock.
When servicing the generator:
Disconnect the spark plug wire and place it where it
cannot contact the plug.
DO NOT check for spark with the plug removed.
Use only approved spark plug testers.
WARNING
Running engines produce heat. Severe burns can
occur on contact.
Combustible material can catch fi re on contact.
DO NOT touch hot surfaces.
Avoid contact with hot exhaust gases.
Allow equipment to cool before touching.
Maintain at least 3 ft. (91.4 cm) of clearance on all
sides to ensure adequate cooling.
Maintain at least 5 ft. (1.5 m) of clearance from
combustible materials.
WARNING
Medical and Life Support Uses.
In an emergency, call emergency services immediately.
NEVER use this product to power life support
devices or life support appliances.
NEVER use this product to power medical devices
or medical appliances.
Inform your electricity provider immediately if you
or anyone in your household depends on electrical
equipment to live.
Inform your electrical provider immediately if a
loss of power would cause you or anyone in your
household to experience a medical emergency.
WARNING
The engine exhaust from this product contains
chemicals that are known to cause serious health
problems and even death.
WARNING
Read this manual thoroughly before operating your
generator. Failure to follow instructions could result
in serious injury or death.
WARNING
5
SAFETY RULES
Improper treatment or use of the generator can
damage it, shorten its life and void your warranty.
Use the generator only for intended uses.
Operate only on level surfaces.
DO NOT expose generator to excessive moisture,
dust, or dirt.
DO NOT allow any material to block the cooling slots.
If connected devices overheat, turn them off and
disconnect them from the generator.
DO NOT use the generator if:
Electrical output is lost
Equipment sparks, smokes or emits fl ames
–Equipment vibrates excessively
CAUTION
Rapid retraction of the starter cord will pull hand and
arm towards the engine faster than you can let go.
Unintentional startup can result in serious injury.
Broken bones, fractures, bruises or sprains could result.
When starting engine, pull the starter cord slowly
until resistance is felt and then pull rapidly to avoid
kickback.
DO NOT start or stop the engine with electrical
devices plugged in.
WARNING
Exceeding the generator’s running capacity can
damage the generator and/or electrical devices
connected to it.
DO NOT overload the generator.
Start the generator and allow the engine to stabilize
before connecting electrical loads.
Connect electrical equipment in the off position,
and then turn them on for operation.
Turn electrical equipment off before stopping the
generator.
DO NOT tamper with the governed speed.
DO NOT modify the generator in any way.
CAUTION
Operation of this equipment may create sparks that
can start fi res around dry vegetation.
A spark arrestor may be required. The operator
should contact local fi re agencies for laws or
regulations relating to fi re prevention requirements.
WARNING
Fuel and fuel vapors are highly fl ammable and
extremely explosive.
Fire or explosion can cause severe burns or death.
Unintentional startup can result in entanglement,
traumatic amputation or laceration.
When adding or removing fuel:
Turn the generator off and let it cool for at least two
minutes before removing the fuel cap. Loosen the
cap slowly to relieve pressure in the tank.
Only fi ll or drain fuel outdoors in a well-ventilated area.
DO NOT pump gas directly into the generator at the
gas station. Use an approved container to transfer
the fuel to the generator.
DO NOT overfi ll the fuel tank.
Always keep fuel away from sparks, open fl ames,
pilot lights, heat and other sources of ignition.
DO NOT light or smoke cigarettes.
When starting the generator:
DO NOT attempt to start a damaged generator.
Make certain that the gas cap, air fi lter, spark plug,
fuel lines and exhaust system are properly in place.
Allow spilled fuel to evaporate fully before
attempting to start the engine.
Make certain that the generator is resting fi rmly on
level ground.
When operating the generator:
DO NOT move or tip the generator during operation.
DO NOT tip the generator or allow fuel or oil to spill.
When transporting or servicing the generator:
Make certain that the fuel shutoff valve is in the off
position and the fuel tank is empty.
Disconnect the spark plug wire.
When storing the generator:
Store away from sparks, open fl ames, pilot lights,
heat and other sources of ignition.
DANGER
EN
6
ASSEMBLY
Your generator requires some assembly. This unit ships
from our factory without oil. It must be properly serviced
with fuel and oil before operation.
If you have any questions regarding the assembly of your
generator, contact yor local dealer. Please have your serial
number and model number available.
Remove the Generator from the Shipping Carton
1. Set the shipping carton on a solid, fl at surface.
2. Remove everything from the carton except the
generator.
3. Carefully cut each corner of the box from top to
bottom. Fold each side fl at on the ground to provide a
surface area to install the wheel kit and support leg.
Install the Wheel Kit (Optional Extra)
You will need the following tools to install the wheels:
17 mm wrench OR adjustable wrench (not included)
Socket wrench with a 16 mm socket (not included)
Pliers (not included)
1. Before adding fuel and oil, tip the generator on its side.
2. Slide the M10x120 fl ange bolt through the washer,
sleeve and wheel.
3. Slide the bolt through the mount point on the frame.
4. Fasten securely with the M10 lock nut.
5. Repeat steps 2-4 to attach the second wheel.
Install the Support Leg
1. Attach the vibration mounts to the support leg with
a fl ange bolt M8 x 25 and fl ange lock nuts.
2. Attach the support leg to the generator frame with
ange bolts M8 x 16 and fl ange lock nuts and
fasten securely. DO NOT over tighten the lock nuts.
3. Tip the generator slowly so that it rests on the
wheels and support leg.
The wheel kit is not intended for over-the-road use.
CAUTION
Connect the Battery (Electric Start Models
only)
1. Remove the protective cover from the red (+) lead on
the battery.
2. Attach the red (+) lead to the red (+) terminal on the
battery with the cap screw (M5x10) and secure with
the lock washer (M5).
3. Repeat steps 1-2 for the black (–) battery lead.
7
1. Place the generator on a fl at, level surface.
2. Remove oil fi ll cap/dipstick to add oil.
3. Add oil and replace oil fi ll cap/dipstick. DO NOT
OVERFILL.
4. Check engine oil level daily and add as needed.
The recommended oil type is 10W-30 automotive oil.
NOTE
The engine is equipped with a low oil shut-off and
will stop when the oil level in the crankcase falls
below the threshold level.
CAUTION
Add Engine Oil
DO NOT attempt to crank or start the engine before
it has been properly fi lled with the recommended
type and amount of oil. Damage to the generator as
a result of failure to follow these instructions will
void your warranty.
CAUTION
ASSEMBLY
Check oil often during the break-in period. Refer to the
Maintenance section for recommended service intervals.
NOTE
The generator rotor has a sealed, pre-lubricated ball
bearing that requires no additional lubrication for
the life of the bearing.
NOTE
Add Engine Oil Contd.
Synthetic oil may be used after the 5 hour initial
break-in period. Using synthetic oil does not
increase the recommended oil change interval.
Full synthetic 5W-30 oil will aid in starting in cold
ambient <5ºC (41ºF)
NOTE
We consider the fi rst 5 hours of run time to be
the break-in period for the unit. During the break
in period stay at or below 50% of the running
watt rating and vary the load occasionally to allow
stator windings to heat and cool. Adjusting the
load will also cause engine speed to vary and help
seat piston rings. After the 5 hour break-in period,
change the oil.
NOTE
Weather will affect engine oil and engine
performance. Change the type of engine oil used
based on weather conditions to suit the engine
needs.
NOTE
Once oil has been added, a visual check should show
oil about 1-2 threads from running out of the fi ll hole.
If using the dipstick to check oil level, DO NOT screw
in the dipstick while checking.
NOTE
Full Synthetic 5W-30
Degrees Celsiusº (Outside)
(Outside)
Degrees Fahrenheitº
EN
8
ASSEMBLY
Add Fuel Cont’d.
Grounding
Your generator must be properly connected to an
appropriate ground to help prevent electric shock.
A ground terminal connected to the frame of the generator
has been provided on the power panel. For remote
grounding, connect of a length of heavy gauge
(12 AWG minimum) copper wire between the generator
ground terminal and a copper rod driven into the ground.
We strongly recommend that you consult with a qualifi ed
electrician to ensure compliance with local electrical codes.
Failure to properly ground the generator can result
in electric shock.
WARNING
Our engines work well with 10% or less ethanol
blend fuels. When using blended fuels there are
some issues worth noting:
Ethanol-gasoline blends can absorb more water
than gasoline alone.
These blends can eventually separate, leaving
water or a watery goo in the tank, fuel valve and
carburetor.
With gravity-fed fuel supplies, this compromised
fuel can be drawn into the carburetor and cause
damage to the engine and/or potential hazards.
There are only a few suppliers of fuel stabilizer
that are formulated to work with ethanol blend
fuels.
Any damages or hazards caused by using
improper fuel, improperly stored fuel, and/
or improperly formulated stabilizers, are not
covered by manufactures warranty.
It is advisable to always shut off the fuel supply,
run the engine to fuel starvation and drain the tank
when the equipment is not in use for more than 30
days.
NOTE
Add Fuel
1. Use clean, fresh, regular unleaded fuel with a
minimum octane rating of 85 and an ethanol content
of less than 10% by volume.
2. DO NOT mix oil with fuel.
3. Clean the area around the fuel cap.
4. Remove the fuel cap.
5. Slowly add fuel to the tank. DO NOT OVERFILL. Fuel
can expand after fi lling. A minimum of
¼ in. (6.4 mm) of space left in the tank is required
for fuel expansion, more than ¼ in. (6.4 mm) is
recommended. Fuel can be forced out of the tank as
a result of expansion if it is overfi lled, and can affect
the stable running condition of the product. When
lling the tank, it is recommended to leave enough
space for the fuel to expand.
6. Screw on the fuel cap and wipe away any spilled fuel.
Use regular unleaded gasoline with a minimum
octane rating of 85.
Do not mix oil and gasoline.
Fill tank to approximately ¼ in. (6.4 mm) below the
top of the tank to allow for fuel expansion.
DO NOT pump gas directly into the generator at the
gas station. Use an approved container to transfer
the fuel to the generator.
DO NOT fi ll fuel tank indoors.
DO NOT fi ll fuel tank when the engine is running or hot.
DO NOT overfi ll the fuel tank.
DO NOT light cigarettes or smoke when fi lling the
fuel tank.
CAUTION
Pouring fuel too fast through the fuel screen may
result in blow back of fuel at the operator while fi lling.
WARNING
9
OPERATION
Generator Location
Never operate the generator inside any building! (See
safety warnings section). In some areas generators must
be registered with the local utility company. Generators
used on construction sites may be subject to local
rules and regulations. Keep on a fl at, level surface.
Generators must have at least 5 ft (1.5m) clearance
from all combustible material. In addition they must
have at least 3 ft (91.4cm) of clearance on all sides to
allow for adequate cooling, maintenance and servicing.
Generators should never be started or operated in ant
location that will not allow for adequate cooling of
the generator and/or the muf er. Allow generators to
cool before storage or transportation. Do not place the
generator near any vents or intakes. Carefully consider
wind and air currents when placing generator.
Failure to follow proper safety precautions may void
manufacturer’s warranty.
Do not operate or store the generator in rain, snow,
or wet weather.
Using a generator or electrical appliance in wet
conditions, such as rain or snow, or near a pool or
sprinkler system, or when your hands are wet, could
result in electrocution.
WARNING
WARNING
During operation the muf er and exhaust fumes
produced will become hot. If adequate cooling and
breathing space are not supplied, or if the generator
is blocked or contained, temperatures can become
extremely heated and may lead to fi re.
Surge Protection
Electronic devices, including computers and many
programmable appliances use components that are
designed to operate within a narrow voltage range and
may be affected by momentary voltage fl uctuations.
While there is no way to prevent voltage fl uctuations, you
can take steps to protect sensitive electronic equipment.
1. Install UL1449, CSA-listed, plug-in surge suppressors
on the outlets feeding your sensitive equipment.
Surge suppressors come in single- or multi-outlet
styles. They’re designed to protect against virtually
all short-duration voltage fl uctuations.
Voltage uctuation may impair the proper
functioning of sensitive electronic equipment.
CAUTION
Starting the Engine
1. Make certain the generator is on a fl at, level surface.
2. Disconnect all electrical loads from the generator.
Never start or stop the generator with electrical
devices plugged in or turned on.
3. Turn the Fuel Valve to the “ON” position.
4. Move the choke lever to the “CHOKE” position.
5. Flip the ignition switch to the “ON” position.
6. For models that have an ELECTRIC START: Press
and hold the ignition switch to the “START” position.
Release as the engine begins to roll over. If the engine
fails to start within fi ve seconds, release the switch
and wait at least ten seconds before attempting to
start the engine again.
7. RECOIL START: Pull the starter cord slowly until
resistance is felt and then pull rapidly
8. Do not over-choke. As as soon as engine starts, move
the choke lever to the “RUN” position.
Grounding
The generator system ground connects the frame to the
ground terminals on the power panel. The system ground is
connected to the AC neutral wire.
EN
10
Connecting Electrical Loads
1. Let the engine stabilize and warm up for a few
minutes after starting
2. Plug in and turn on the desired 120/240 Volt AC
single phase, 50 Hz electrical loads.
DO NOT connect 3-phase loads to the generator.
DO NOT connect 60 Hz loads to the generator.
DO NOT overload the generator.
Connecting a generator to your electric utility company’s
power lines or to another power source may be against
the law. In addition this action, if done incorrectly, could
damage your generator and appliances and could cause
serious injury or even death to you or a utility worker
who may be working on nearby power lines. If you plan
to run a portable electric generator during an outage,
please notify your electric utility company immediately
and remember to plug your appliances directly into the
generator. Do not plug the generator into any electric
outlet in your home. Doing so could create a connection
to the utility company power lines. You are responsible
for ensuring that your generator’s electricity does not
feed back into the electric utility power lines.
If the generator will be connected to a building electrical
system, consult your local utility company or a qualifi ed
electrician. Connections must isolate generator power
from utility power and must comply with all applicable
laws and codes.
NOTE
OPERATION
Stopping the Engine
1. Turn off and unplug all electrical loads. Never start
or stop the generator with electrical devices plugged
in or turned on.
2. Let the generator run at no-load for several minutes
to stabilize internal temperatures of the engine and
generator.
3. Turn the Fuel Valve to the “OFF” position.
4. Let the engine run until fuel starvation has stopped
the engine. This usually takes a few minutes.
5. Press the Ignition Switch to the “OFF” position.
Important: Always ensure that the Fuel Valve and the
Ignition Switch are in the “OFF” position when the
engine is not in use.
If the engine will not be used for a period of two (2) weeks
or longer, please see the Storage section for proper engine
and fuel storage.
NOTE
If the engine starts but does not run make certain
that the generator is on a fl at, level surface. The
engine is equipped with a low oil sensor that will
prevent the engine from running when the oil level
falls below a critical threshold.
NOTE
Keep choke lever in “Choke” position for only 1
pull of the recoil starter. After fi rst pull, move
choke lever to the “Run” position for up to the next
3 pulls of the recoil starter. Too much choke will
cause the engine not to start.
NOTE
When the battery switch is in the “ON” position,
the switch will light up if the battery is sending
out a charge. If the switch does not light up while
in the “ON” position, check that the battery
connection is still good.
NOTE
The supplied 12V 15AH battery does re-charge
while the engine is running, but it is also
recommended that the battery be fully charged at
least once per month.
NOTE
Starting the Engine Cont’d. Connecting Electrical Loads Contd.
11
Do Not Overload Generator
Capacity
Follow these simple steps to calculate the running and
starting watts necessary for your purposes.
1. Select the electrical devices you plan on running at
the same time.
2. Total the running watts of these items. This is
the amount of power you need to keep your items
running.
3. Identify the highest starting wattage of all devices
identifi ed in step 1. Add this number to the number
calculated in step 2. Surge wattage is the extra
burst of power needed to start some electric driven
equipment. Following the steps listed under “Power
Management” will guarantee that only one device will
be starting at a time.
Power Management
Use the following formula to convert voltage and
amperage to watts:
Volts x Amps = Watts
To prolong the life of your generator and attached
devices, follow these steps to add electrical load:
1. Start the generator with no electrical load attached
2. Allow the engine to run for several minutes to stabilize.
3. Plug in and turn on the fi rst item. It is best to attach
the item with the largest load fi rst.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
Never exceed the specifi ed capacity when adding
loads to the generator.
NOTE
OPERATION
Operation at High Altitude
Be aware that engine effi ciency can reduce and exhaust
emissions increase when working at high altitude.
Other high altitude issues can include hard starting,
increased fuel consumption and spark plug fouling.
This is a natural trend and cannot be altered by engine
adjustment.
An Important Message About Temperature
Your Champion Power Equipment product is designed
and rated for continuous operation at ambient
temperatures up to 40°C (104°F). When your product is
needed your product may be operated at temperatures
ranging from -l5°C (5°F) to 50°C (122°F) for short
periods. If the product is exposed to temperatures
outside this range during storage, it should be brought
back within this range before operation. In any event,
the product must always be operated outdoors, in a well-
ventilated area and away from doors, windows and other
vents.
EN
12
MAINTENANCE AND STORAGE
The owner/operator is responsible for all periodic
maintenance.
Complete all scheduled maintenance in a timely manner.
Correct any issue before operating the generator.
Never operate a damaged or defective generator.
Tampering with the factory set governor will void
your warranty.
Engine Maintenance
To prevent accidental starting, remove and ground spark
plug wire before performing any service.
Oil
Change oil when the engine is warm. Refer to the oil
specifi cation to select the proper grade of oil for your
operating environment.
1. Remove the oil drain plug with a 15 mm socket and
extension (not included).
2. Allow the oil to drain completely.
3. Replace the drain plug.
4. Remove oil fi ll cap/dipstick to add oil.
5. Add oil and replace oil fi ll cap/dipstick. DO NOT
OVERFILL.
6. Dispose of used oil at an approved waste
management facility.
Spark Plugs
1. Remove the spark plug cable from the spark plug.
2. Remove the plug.
3. Inspect the electrode on the plug. It must be clean and
not worn to produce the spark required for ignition.
4. Refer to spark plug information located in the
“specifi cation” page for this model.
5. Carefully thread the plug into the engine.
6. Use the spark plug tool (not included) to fi rmly install
the plug.
7. Attach the spark plug wire to the plug.
Maintenance, replacement, or repair of emission
control devices and systems may be performed
by any non-road engine repair establishment or
individual.
NOTE
WARNING
WARNING
Improper maintenance will void your warranty.
WARNING
Oil Cont’d.
Once oil has been added, a visual check should show
oil about 1-2 threads from running out of the fi ll hole.
If using the dipstick to check oil level, DO NOT screw
in the dipstick while checking.
NOTE
Maintenance Valve Clearance
OEM spark plug: NHSP F6RTC
Replacement spark plug: NGK BPR6ES or equivalent
Make certain the *spark plug gap is 0.7 - 0.8 mm or
(0.028 - 0.031 in.).
- Intake: 0.13 - 0.17 mm (0.005 - 0.007 in.)
- Exhaust: 0.18 - 0.22 mm (0.007 - 0.009 in.)
Note: Tech bulletin regarding the valve adjustment
procedure is on www.championpowerequipment.com
0.7-0.8 mm
0.028-0.031 in.
13
Adjustments
The air-fuel mixture is not adjustable. Tampering with
the governor can damage your generator and your
electrical devices and will void your warranty. CPE
recommends that you contact your local dealer for all
other service and/or adjustment needs.
Maintenance Schedule
Follow the service intervals indicated in the following
maintenance schedule.
Service your generator more frequently when operating
in adverse conditions.
Use a damp cloth to clean exterior surfaces of the engine.
Use a soft bristle brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris
from the engine.
Cleaning
DO NOT spray engine with water.
CAUTION
Water can contaminate the fuel system.
Spark Arrester
1. Allow the engine to cool completely before servicing
the spark arrester.
2. Remove the screws holding the cover plate which
retains the end of the spark arrester to the muffl er.
3. Remove the spark arrester screen.
4. Carefully remove the carbon deposits from the spark
arrester screen with a wire brush.
5. Replace the spark arrester if it is damaged.
6. Position the spark arrester in the muffl er and attach
with the three screws.
Failure to clean the spark arrester will result in degraded
engine performance.
CAUTION
Federal and local laws and administrative requirements
indicate when and where spark arresters are required.
NOTE
*To be performed by knowledgeable, experienced owners or
Champion Power Equipment certifi ed dealers.
MAINTENANCE AND STORAGE
Generator Maintenance
Make certain that the generator is kept clean and stored
properly. Only operate the unit on a fl at, level surface in
a clean, dry operating environment. DO NOT expose the
unit to extreme conditions, excessive dust, dirt, moisture
or corrosive vapors.
Use a damp cloth to clean exterior surfaces of the generator.
Use a soft bristle brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris
from the generator.
Inspect all air vents and cooling slots to ensure that they
are clean and unobstructed.
DO NOT use a garden hose to clean the generator.
Water can enter the generator through the cooling
slots and damage the generator windings.
CAUTION
Every 8 hours or daily
Check oil level
Clean around air intake and muffl er
First 5 Hours
Change oil
Every 50 hours or every season
Clean air fi lter
Change oil if operating under heavy load or in hot
environments
Every 100 hours or every season
Change oil
Clean/Adjust spark plug
Check/Adjust valve clearance*
Clean spark arrester
Clean fuel tank and fi lter*
Every 250 hours
Clean combustion chamber*
Every 3 years
Replace fuel line
Air Filter
1. Remove the snap-on cover holding the air fi lter to
the assembly.
2. Remove the foam element.
3. Wash in liquid detergent and water. Squeeze
thoroughly dry in a clean cloth.
4. Saturate in clean engine oil.
5. Squeeze in a clean, absorbent cloth to remove all
excess oil.
6. Place the fi lter in the assembly.
7. Reattach the air fi lter cover and snap in place.
EN
14
MAINTENANCE AND STORAGE
Storage
The generator should be started at least once every 14
days and allowed to run for at least 20 minutes. For
longer term storage, please follow these guidelines.
Generator Storage
1. Add a properly formulated fuel stabilizer to the tank.
2. Be sure all appliances are disconnected from the
generator.
3. Run the generator for a few minutes so the treated
fuel cycles through the fuel system and carburetor.
4. Turn the fuel valve to the “Off” position.
5. Let the generator run until fuel starvation has
stopped the engine. This usually takes a few minutes.
6. The generator needs to cool acompletely before
cleaning and storage.
7. Clean the generator according to the maintenance
section.
8. Change the oil.
9. Remove the spark plug and pour about 12 ounce
(14.8 mL) of oil into the cylinder. Crank the engine
slowly to distribute the oil and lubricate the cylinder.
10. Reattach the spark plug.
11. Store the unit in a clean, dry place out of direct
sunlight.
Battery
Some frame type generators are equipped with an
automatic battery charging circuit. The battery will
receive charging voltage when the engine is running. The
battery will maintain a proper charge if the unit is used
on a regular basis (about once every two weeks). If it is
used less frequently, the battery should be connected
to a trickle charger or battery maintainer to keep the
battery properly charged. If the battery is not able to
start the engine, it can be started by manually pulling
the engine recoil cord. If the battery voltage is extremely
low, the charging circuit may not be able to re-charge
the battery. In this case, the battery must be connected
to a standard automotive style battery charger for re-
charging before it can be used.
Disconnect the Battery
1. Remove the protective cover from the black/negative
battery lead.
2. Disconnect the black/negative lead from the black/
negative terminal on the battery and store the cap
screw and lock washer.
3. Repeat steps 1-2 for the red/positive battery lead.
4. Store the battery in a cool, dry place.
A Float Charger will maintain the battery condition
over long storage periods.
NOTE
Charge the Battery
For generators equipped with batteries for electric
starting, proper battery maintenance and storage should
be followed. An automatic battery charger (not included)
with automatic trickle charging capability should be used
to charge the battery. Maximum charging rate should not
exceed 1.5 amps. Follow the instructions included with
the battery charger. The battery should be fully charged
at least once per month.
Generator exhaust contains odorless and colorless
carbon monoxide gas.
To avoid accidental or unintended ignition of your
electric start generator during periods of storage,
the following precautions should be followed:
When storing the generator for short periods of
time make sure that the Ignition Switch and the
FuelValve are set in the OFF position.
When storing the generator for extended periods
of time make sure that the Ignition Switch and
the Fuel Valve are set in the OFF position and
the battery leads have been disconnected from
the battery.
DANGER
15
TROUBLESHOOTING
Problem Cause Solution
Generator will not start
No fuel Add fuel
Faulty spark plug Replace spark plug
Unit loaded during start up Remove load from unit
Generator will not start;
Generator starts but runs roughly
Low oil level Fill crankcase to the proper level
Place generator on a fl at, level surface
Choke in the wrong position. Adjust choke.
Spark plug wire loose Attach wire to spark plug
Generator will not start electrically Generator battery is dead Recharge generator battery
Generator shuts down during operation
Out of fuel Fill fuel tank
Low oil level Fill crankcase to the proper level. Place
generator on a fl at, level surface
Generator cannot supply enough power or
overheating
Generator is overloaded Review load and adjust. See “Power
Management
Insuf cient ventilation Check for air restriction. Move to a well
ventilated area
No AC output
Cable not properly connected Check all connections
Connected device is defective Replace defective device
Circuit breaker is open Reset circuit breaker
Faulty brush assembly Replace brush assembly (Service Center)
Faulty AVR (auto voltage regulator) Replace AVR (Service Center)
Loose wiring Inspect and tighten wiring connections
Other Contact the help line.
Generator gallops Engine governor defective Contact the help line
Repeated circuit breaker tripping
Overload Review load and adjust. See “Power
Management
Faulty cords or device Check for damaged, bare or frayed wires.
Replace defective device
EN
16
INTRODUKTION
Notera modell- och serienummer samt datum och inköpsställe för framtida behov. Ha denna information tillgänglig
vid beställning av reservdelar och vid tekniska eller garanti-förfrågningar.
Champion Power Equipment support
Modellnummer
Serienummer
Inköpsdatum
Inköpsplats
För oljetyp, se avsnittet “Fyll på olja. För bränsletyp, se avsnittet “Fyll på bränsle”.
Introduktion
Grattis till att ha köpt denna generator. Vårda och ta
hand om den korrekt.
Portabel strömgenerator
Denna enhet är en bensinmotordriven
växelströmsgenerator som används för att generera
elektrisk ström.
Tillbehör
CPE tillverkar och tillhandahåller en mängd olika
tillbehör. Se din lokala handlare för mer information.
Denna broschyr
Vi förbehåller oss rätten att ändra eller förbättra
produkten eller denna manual utan vidare förvarning.
0046 31 280985
17
MANUALENS SYMBOLER
nligen gör dig bekant med följande symboler. Säkerhetssymbolen och nyckelorden är säkerhetsvarningar.
lj alla säkerhetsmeddelanden för att undvika olyckor eller personskador.
FARA anger en potentiellt farlig situation som,
omden inte undviks, kan leda till mindre eller
måttliga personskador.
CAUTION
VARNING utan symbolen för säkerhetsvarning anger
en potentiellt farlig situation som, om den inte
undviks, kan leda till skador på egendom.
CAUTION
FARA anger en omedelbart farlig situation som,
om den inte undviks, kommer att leda till död
ellerallvarlig personskada.
DANGER
FARA anger en potentiellt farlig situation som,
omden inte undviks, kan leda till död eller
allvarligpersonskada.
WARNING
Om du har frågor om din generator kan vi hjälpa dig.
Vänligen kontakta din lokala handlare.
NOTE
SV
18
SÄKERHETSREGLER
Generatoravgaser innehåller kolmonoxid som är en
färglös, doftfri, giftig gas. Att andas in kolmonoxid
kommer att orsaka illamående, yrsel, svimning eller
död. Om du börjar känna dig yr eller svag, se till att
få frisk luft omedelbart.
Använd generatorn utomhus och på en väl
ventilerad plats.
ANVÄND INTE generatorn inomhus. Detta
inkluderar garage, källare, kryputrymmen,
förråd, inhägnader eller avdelningar samt
generatorutrymmen i husbilar eller husvagnar.
LÅT INTE avgasångor tränga in i stängda utrymmen
genom fönster, dörrar, ventiler eller andra
öppningar.
KOLMONOXIDVARNING: att använda en generator
inomhus KAN DÖDA DIG PÅ ETT PAR MINUTER.
DANGER
Roterande delar kan trassla in händer, fötter,
hår, kläder och/eller accessoarer. Traumatiska
amputationer eller allvarliga skärsår kan uppstå.
Se till att hålla händer och fötter borta från roterande
delar.
Sätt upp långt hår och ta bort smycken.
Använd utrustning med skydd på plats.
ANVÄND INTE löst sittande kläder, hängande snören
eller andra saker som kan fastna eller ryckas in.
DANGER
Generatorn producerar kraftfull spänning.
RÖR INTE nakna sladdar eller kärl.
ANVÄND INTE elektriska sladdar som är slitna, skadade
eller trasiga.
ANVÄND INTE generatorn i vått väder.
TILLÅT INTE barn eller okvali cerade personer att
hantera eller genomföra underhåll på generatorn.
Använd en säkerhetsbrytare på fuktiga ställen eller på
ställen med strömförande material såsom metallunderlag.
Använd godkänd överföringsutrustning för att isolera
generatorn från dina elektriska verktyg och meddela ditt
elbolag innan du ansluter din generator till elnätet.
DANGER
Gnistor kan resultera i brand eller elektriska stötar.
Vid underhåll av generatorn:
Koppla ifrån sladden till tändstiftet och placera den
såatt den inte kan komma i kontakt med tändstiftet.
Undersök INTE om det bildas gnistor när tändstiftet
ärborttaget.
Använd endast godkända testare av tändstift.
WARNING
Att köra motorer som producerar hetta. Allvarliga
skador kan uppstå vid kontakt.
Brännbart material kan fatta eld vid kontakt.
RÖR INTE heta ytor.
Undvik kontakt med heta avgaser.
Låt utrustning svalna av innan den vidrörs.
Se till att hålla ett avstånd på minst 1 meter
(ca3 ft.) på alla sidor för att säkerställa tillräcklig
avkylning.
Se till att hålla ett avstånd på minst 1,5 meter
(ca5 ft.) från brännbart material.
WARNING
Medicinsk och livsuppehållande användning.
Kontakta larmassistans omedelbart i händelse av en
olycka.
ANVÄND ALDRIG den här produkten för att driva
livsuppehållande enheter eller apparater.
ANVÄND ALDRIG den här produkten för att driva
medicinska enheter eller apparater.
Informera din elleverantör omedelbart om någon
iditt hushåll är beroende av elektrisk utrustning
föratt överleva.
Informera din elleverantör omedelbart om någon
iditt hushåll skulle uppleva en medicinsk kris
utantillgänglig elektricitet.
WARNING
Avgaserna från den här produkten innehåller
kemikalier som är dokumenterat skadliga för
hälsaneller t.o.m. dödliga.
WARNING
Läs denna manual noggrant innan du använder din
generator. Att avvika från instruktionerna kan leda
till allvarliga skador eller död.
WARNING
19
SÄKERHETSREGLER
Olämplig hantering eller användning av din
generator kan skadad den, förkorta dess livslängd
och göra garantin ogiltig.
Använd endast generatorn på avsett sätt.
Använd endast på jämn, platt mark.
UTSÄTT INTE generatorn för överdriven fukt, damm
eller smuts.
LÅT INTE något material blockera
ventilationsöppningarna.
Om anslutna enheter överhettas ska de stängas av
och kopplas bort från generatorn.
ANVÄND INTE generatorn om:
Den inte alstrar någon elektricitet
Utrustningen ger gnistor, rök eller eld
Utrustningen vibrerar överdrivet
CAUTION
Den snabba rekylen av startsnöret kan slita med sig
hand och arm mot motorn snabbare än du hinner
släppa taget.
Oavsiktlig start kan resultera i allvarliga
personskador.
Brutna ben, frakturer, blåmärken eller stukningar kan
bli resultatet.
När du ska starta motorn, dra startsnöret långsamt
tills du känner motstånd och dra då snabbt för att
undvika rekyl.
STARTA eller STANNA INTE motorn med några
elektriska enheter anslutna.
WARNING
Att överstiga generatorns driftkapacitet kan skada
generatorn och/eller de elektriska enheter som är
kopplade till den.
ÖVERBELASTA INTE generatorn.
Starta generatorn och låt motorn stabiliseras innan
du ansluter någon elektrisk belastning.
Anslut elektrisk utrustning när den är avstängd och
sätt sedan på den efter anslutning.
Stäng av elektrisk utrustning innan du stänger av
generatorn.
MIXTRA INTE med den reglerade hastigheten.
MODIFIERA INTE generatorn på något vis.
CAUTION
Användning av den här utrustningen kan generera
gnistor som kan starta brand i torr vegetation.
Ett gnistskydd kan krävas. Användaren bör kontakta
den lokala brandskyddsmyndigheten beträffande
gällande brandskyddsbestämmelser.
WARNING
Bränsle och bränsleångor är mycket brandfarliga
och extremt explosiva.
Brand eller explosion kan orsaka allvarliga
brännskador eller död.
Oavsiktlig start kan resultera i intrassling,
traumatisk amputation eller skärsår.
Vid påfyllning eller tömning av bränsle:
Stäng av generatorn och låt den svalna i minst
två minuter innan du tar bort locket till bränslet.
Lossaförsiktigt på locket för att släppa ut trycket
ur tanken.
Fyll eller töm endast utomhus på en väl ventilerad
plats.
PUMPA INTE bensin direkt in i generatorn på
bensinstationen. Använd en godkänd behållare
för att fylla på bränslet i generatorn.
ÖVERFYLL INTE bränsletanken.
Se alltid till att hålla bränsle borta från gnistor,
öppen eld, glöd, hetta eller andra antändningskällor.
TÄND INTE eller rök cigaretter.
Vid start av generatorn:
Försök ALDRIG att starta en skadad generator.
Se till att bensinlock, luftfi lter, tändstift,
bränsleslangar och avgassystem sitter ordentligt
på plats.
Låt utspillt bränsle att dunsta bort ordentligt innan
du försöker starta motorn.
Se till att generatorn står stadigt på platt mark.
Vid användning av generatorn:
FLYTTA eller TIPPA INTE generatorn under
användning.
TIPPA INTE generatorn eller låt bränsle eller oljaatt
spillas ut.
Vid transport eller underhåll av generatorn:
Se till att bränslets avstängningsventil är stängd
och att bränsletanken är tom.
Koppla ifrån sladden till tändstiftet.
Vid förvaring av generatorn:
Förvara borta från gnistor, öppen eld, glöd,
hettaeller andra antändningskällor.
DANGER
SV
20
MONTERING
Din generator kräver en viss montering. Denna
enhet levereras från vår fabrik utan olja. Den måste
underhållas ordentligt med bränsle och olja innan den
används.
Om du har några frågor om monteringen av din
generator, vänligen kontakta din lokala handlare.
nligen se till att ha ditt serienummer och
modellnummer till hands.
Ta bort generatorn från
leveransförpackningen.
1. Placera leveransförpackningen på en stabil platt yta.
2. Ta bort allting från kartongen förutom generatorn.
3. Skär försiktigt upp varje hörn på lådan från topp till
botten. Vik ner varje sida platt på marken för att
få en yta att kunna installera hjulutrustningen och
stödbenet.
Installera hjulutrustningen (extra tillval)
Du kommer att behöva följande verktyg för att installera
hjulen:
17 mm skruvnyckel ELLER skiftnyckel (ingår inte)
Hylsnyckel med 16 mm hylsa (ingår inte)
ng (ingår inte)
1. Innan du fyller på bränsle eller olja, tippa generatorn
på sidan.
2. För in M10x120-fl änsbulten genom bricka, bussning
och hjul.
3. För in bulten genom monteringspunkten på ramen.
4. Fäst ordentligt med M10-låsbulten.
5. Upprepa steg 2-4 för att fästa det andra hjulet.
Installera stödbenet
1. Fäst vibrationsfästena på stödbenet med fl änsbultar
M8 x 25 och fl änslåsmuttrar.
2. Fäst stödbenet på generatorramen med fl änsbultar
M8 x 16 och fl änslåsmuttrar och dra åt ordentligt.
DRA INTE åt låsmuttrarna för hårt.
3. Tippa generatorn försiktigt så att den vilar på hjulen
och stödbenet.
Hjulutrustningen är inte avsedd för vägtrafi k.
CAUTION
Anslut batteriet (endast elektriska
startmodeller)
1. Ta bort det skyddande höljet från den röda
pluspoolen (+) på batteriet.
2. Fäst den röda pluspoolen (+) på den röda
plusterminalen (+) med lockskruven (M5x10)
ochsäkra med låsbrickan (M5).
3. Upprepa steg 1-2 för den svarta minuspoolen (-).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96

Champion CPG2500 Användarmanual

Kategori
Kraftgeneratorer
Typ
Användarmanual