Dometic Büttner MT ICC 1600 SI-N, MT ICC 3000 SI-N Bruksanvisningar

  • Hej! Jag är en AI-chatbot som är tränad för att hjälpa dig med Dometic Büttner MT ICC 1600 SI-N, MT ICC 3000 SI-N Bruksanvisningar. Jag har redan gått igenom dokumentet och kan ge dig klara och enkla svar.
MTICC1600SI-N, MTICC3000SI-N
Inverter charger combination
Installation and Operating Manual. . . . . . . 12
Wechselrichter/Ladegerät
Kombination
Montage- und Bedienungsanleitung . . . . .34
Combiné onduleur-chargeur
nstructions de montage et de service . . . .58
Combinazione inverter/caricatore
Istruzioni di montaggio e d’uso . . . . . . . . .82
Combinatie van omvormer en
oplader
Montagehandleiding en
gebruiksaanwijzing. . . . . . . . . . . . . . . . . . 106
Inverter-oplader-kombination
Monterings- og betjeningsvejledning. . . 129
Växelriktar/laddar-kombination
Monterings- och bruksanvisning . . . . . . . 151
Vekselretter-lader-kombinasjon
Monterings- og bruksanvisning . . . . . . . . 173
EN
DE
FR
IT
NL
DA
SV
NO
POWER & CONTROL
MT ICC
© 2023 Dometic Group. The visual appearance of the contents of this manual is
protected by copyright and design law. The underlying technical design and the
products contained herein may be protected by design, patent or be patent
pending. The trademarks mentioned in this manual belong to Dometic Sweden AB.
All rights are reserved.
4445103626 3
2
1
8
6
7
3
4
9
5
1
2
3
1
89
6
7
4
5
2
4 4445103626
100 %
75 %
50 %
25 %
5 %
1600 W I 12 V I 60
A
Inp. 3
A
Charger ON
Inverter ON
Line
m
a
x
Inp. 6
A
5 % 25 % 50 % 75 % 100 %
charger inverter
A
C in
1
2
31
2
3 4
4
AB
3
4
4445103626 5
100 mm
100 mm
5
58 mm
58 mm
6
187 mm
126 mm
334 mm
MT ICC 1600 SI-N
7
287 mm
286 mm
37 mm5 mm
231 mm
56 mm
144 mm
MT ICC 3000 SI-N
8
6 4445103626
1. 2.
3.
9
1.
2.
1.
2.
3.
BA
0
4445103626 7
4x
2.
1.
B
2x
2.
1.
A
a
8 4445103626
1
2
b
+
PE PENL1 NL1
AC IN AC OUT
+
t250 A
5 % 25 % 50 % 75 % 100 %
charger inverter
A
C in
4
1
3
5
6
2
< 30 m
AC IN AC OUT
c
4445103626 9
RCD RCD
OUT
IN
230 V
230 V
230 V
MCB
d
A
REMOTE
REMOTE
OFF: INV. o OFF
ON: INV. o ON
B
REMOTE
REMOTE
12 V
3
21
e
10 4445103626
2 1
f
PE PE
NL1 NL1
AC IN AC OUT
+
10 A
t425 A
+
2.5 mm²
5 % 25 % 50 % 75 % 100 %
charger inverter
A
C in
3
4
5
7
2
6
1
AC IN
AC OUT
g
4445103626 11
RCD RCD
OUT
IN
230 V
230 V
230 V
MCB
h
A
REMOTE
REMOTE
OFF: INV. o OFF
ON: INV. o ON
B
REMOTE
REMOTE
12 V
2
3 4
1
i
12 4445103626
Please read these instructions carefully and follow all instructions, guide-
lines, and warnings included in this product manual in order to ensure that
you install, use, and maintain the product properly at all times. These instruc-
tions MUST stay with this product.
By using the product, you hereby confirm that you have read all instructions,
guidelines, and warnings carefully and that you understand and agree to
abide by the terms and conditions as set forth herein. You agree to use this
product only for the intended purpose and application and in accordance
with the instructions, guidelines, and warnings as set forth in this product
manual as well as in accordance with all applicable laws and regulations. A
failure to read and follow the instructions and warnings set forth herein may
result in an injury to yourself and others, damage to your product or damage
to other property in the vicinity. This product manual, including the instruc-
tions, guidelines, and warnings, and related documentation, may be subject
to changes and updates. For up-to-date product information, please visit
documents.dometic.com.
Contents
Explanation of symbols . . . . . . . . . . . . . . . . . . . .12
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . .12
Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . .15
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Target group . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Technical description . . . . . . . . . . . . . . . . . . . . .16
Mounting the inverter charger combination . . 20
Connecting the inverter charger combination. .21
Configuring the inverter charger combination. 23
Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Cleaning and maintenance . . . . . . . . . . . . . . . . 27
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Explanation of symbols
D
!
!
A
I
Safety Instructions
Also observe the safety instructions and stip-
ulations issued by the vehicle manufacturer
and authorized workshops.
General safety
DDANGER! Failure to obey these warn-
ings will result in death or serious
injury.
Electrocution hazard
Do not touch exposed cables with your bare
hands. This applies especially when operating
the device from the AC power supply.
To be able to disconnect the device quickly from
the AC power supply, the socket must be close
to the device and be easily accessible.
!WARNING! Failure to obey these
warnings could result in death or
serious injury.
Electrocution hazard
Installation and removal of the device may only
be carried out by qualified personnel.
Do not operate the device if the device itself or
the connection cable is visibly damaged.
If this device's power cable is damaged, the
power cable must be replaced by the manufac-
turer, a service agent or a similarly qualified
person in order to prevent safety hazards.
This device may only be repaired by qualified
personnel. Improper repairs can lead to consid-
erable hazards.
If you disassemble the device:
Detach all connections.
Ensure that no voltage is present on any of the
inputs and outputs.
DANGER!
Safety instruction: Indicates a hazard-
ous situation that, if not avoided, will
result in death or serious injury.
WARNING!
Safety instruction: Indicates a hazard-
ous situation that, if not avoided, could
result in death or serious injury.
CAUTION!
Safety instruction: Indicates a hazard-
ous situation that, if not avoided, could
result in minor or moderate injury.
NOTICE!
Indicates a situation that, if not avoided,
can result in property damage.
NOTE
Supplementary information for operating
the product.
4445103626 13
Do not use the device in wet conditions or sub-
merge in any liquid. Store in a dry place.
Only use accessories that are recommended by
the manufacturer.
Do not modify or adapt any of the components
in any way.
Disconnect the device from the power supply:
Before each cleaning and maintenance
After every use
Before changing a fuse
Before carrying out electrical welding work or
work on the electrical system
Fire hazard/Flammable materials
In event of fire, use a fire extinguisher which is
suitable for electrical devices.
Health hazard
This device can be used by children aged from
8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience and knowledge if they have been
given supervision or instruction concerning use
of the device in a safe way and understand the
hazards involved.
Electrical devices are not toys.
Always keep and use the device out of the reach
of very young children.
Children must be supervised to ensure that they
do not play with the device.
Cleaning and user maintenance shall not be
made by children without supervision.
ANOTICE! Damage hazard
Before start-up, check that the voltage specifica-
tion on the data plate is the same as that of the
power supply.
Ensure that other objects cannot cause a short
circuit at the contacts of the device.
Ensure that the negative and positive poles
never come into contact.
Installing the device safely
DWARNING! Failure to obey these
warnings could result in death or
serious injury.
Explosion hazard
Never mount the device in areas where there is a
risk of gas or dust explosion.
Only install and operate the device in closed,
well-ventilated rooms.
Do not install or operate the device under the
following conditions:
In salty, wet or damp environments
In the vicinity of corrosive fumes
In the vicinity of combustible materials
In areas where there is a risk of explosions
!CAUTION! Failure to obey these cau-
tions could result in minor or moder-
ate injury.
Risk of injury
Ensure that the device is standing firmly.
The device must be set up and fastened in such
a way that it cannot tip over or fall down.
When positioning the device, ensure that all
cables are suitably secured to avoid any form of
trip hazard.
ANOTICE! Damage hazard
Ensure that the mounting surface is capable of
supporting the weight of the device.
Always use sockets which are grounded and
secured by residual current circuit breakers.
Do not place the device near heat sources (heat-
ers, direct sunlight, gas ovens, etc.).
Set up the device in a dry location where it is pro-
tected against splashing water.
Safety when connecting the device
electrically
DDANGER! Failure to obey these warn-
ings will result in death or serious
injury.
Electrocution hazard
For installation on boats:
If electrical devices are incorrectly installed on
boats, corrosion damage might occur. Have the
device installed by a specialist (marine electri-
cian).
If you are working on electrical systems, ensure
that there is somebody close at hand who can
help you in emergencies.
!WARNING! Failure to obey these
warnings could result in death or
serious injury.
Electrocution hazard
Observe the recommended cable cross-sec-
tions.
14 4445103626
Lay the cables so that they cannot be damaged
by the doors or the hood.
Crushed cables can lead to serious injury.
ANOTICE! Damage hazard
Use ductwork or cable ducts if it is necessary to
lay cables through metal panels or other panels
with sharp edges.
•Do not lay the 230 V mains cable and the 12 V
DC cable in the same duct.
•Do not lay the cable so that it is loose or heavily
kinked.
Fasten the cables securely.
Operating the device safely
!CAUTION! Failure to obey these cau-
tions could result in minor or moder-
ate injury.
Electrocution hazard
Before starting the device, ensure that the
power supply line and the plug are dry and the
plug is free from rust or dirt.
Always disconnect the power supply when
working on the device. Do not disconnect any
cables when the device is still in use.
Observe that parts of the device may still con-
duct voltage even if the fuse has blown.
Do not disconnect any cables when the device is
still in use.
ANOTICE! Damage hazard
Ensure that the air inlets and outlets of the device
are not covered.
Ensure a good ventilation.
Do not pull on the connection cables.
The device shall not to be exposed to rain.
Safety precautions when handling
batteries
!WARNING! Failure to obey these
warnings could result in death or
serious injury.
Risk of injury
Batteries contain aggressive and caustic acids.
Avoid battery fluid coming into contact with
your body. If your skin does come into contact
with battery fluid, wash that part of your body
thoroughly with water.
If you sustain any injuries from acids, contact a
doctor immediately.
!CAUTION! Failure to obey these cau-
tions could result in minor or moder-
ate injury.
Risk of injury
When working on batteries, do not wear any
metal objects such as watches or rings.
Lead acid batteries can cause short circuits
which can cause serious injuries.
Wear goggles and protective clothing when you
work on batteries. Do not touch your eyes when
you are working on batteries.
Explosion hazard
Never attempt to charge a frozen or defective
battery.
Place the battery in a frost-free area and wait until
the battery has acclimatised to the ambient tem-
perature. Then start the charging process.
Do not smoke, use an open flame, or cause
sparking near the engine or a battery.
ANOTICE! Damage hazard
Only use rechargeable batteries.
Prevent any metal parts from falling on the bat-
tery. This can cause sparks or short-circuit the
battery and other electrical parts.
Ensure that the polarity is correct when connect-
ing the battery.
Follow the instructions of the battery manufac-
turer and those of the manufacturer of the system
or vehicle in which the battery is used.
If you need to remove the battery, first discon-
nect the ground connection. Disconnect all con-
nections and all consumers from the battery
before removing it.
Only store fully charged batteries. Recharge
stored batteries regularly.
4445103626 15
Immediately recharge deeply discharged lead
batteries to avoid sulfation.
Check the acid level for open lead-acid batteries
regularly.
Safety precautions when handling
lithium batteries
!CAUTION! Failure to obey these cau-
tions could result in minor or moder-
ate injury.
Risk of injury
Only use batteries with integrated battery man-
agement system and cell balancing.
ANOTICE! Damage hazard
Only install the battery in environments with an
ambient temperature of at least 0 °C.
Avoid deep discharge of the batteries.
Scope of delivery
MT ICC 1600 SI-N
MT ICC 3000 SI-N
Accessories
Available as accessories (not included in the scope
of delivery):
Description Quantity
Inverter Charger Combination
ICC 1600 SI-N
1
Temperature sensor with cable (3 m) and
RJ12 plug
1
Mounting screw 4
Battery cable set (2 x 1.5 m/ 35 mm2) with
cable lugs (M8)
1
Remote control 1
Wall mounting box for remote control 1
Connection cable (5 m) with RJ45 plugs
for remote control
1
Mounting screw for remote control 4
Installation and operating manual 1
Description Quantity
Inverter Charger Combination
ICC 3000 SI-N
1
Temperature sensor with cable (3 m) and
RJ12 plug
1
Wall bracket 1
Mounting screw 7
Crimp terminal (M10) 2
Remote control 1
Wall mounting box for remote control 1
Connection cable (5 m) with RJ45 plugs
for remote control
1
Mounting screw for remote control 4
Installation and operating manual 1
Description Ref. no.
ICC Info Control 9620000283
(MT83124)
MT 5000iQ, 100 A shunt 9620000129
(MT01262)
MT 5000iQ, 200 A shunt 9620000218
(MT01265)
MT 5000iQ, 400 A shunt 9620000303
(MT01268)
Fuse set (MT ICC 1600 SI-N) 9620000166
(MT06250)
Fuse set (MT ICC 3000 SI-N) 9620000346
(MT83125)
Fuse, 250 A (MT ICC 1600 SI-N) 9620000212
(MT88250)
Fuse, 425 A (MT ICC 3000 SI-N) 9620003903
(MTHS520)
Battery cable set (2 x 1.5 m/
95 mm2) with cable lugs (M10)
9620000251
(MT83121)
Description Quantity
16 4445103626
Target group
All other actions are intended also for non-profes-
sional users.
Intended use
The inverter charger combination is intended to
convert the house battery voltage (12 V DC) into a
pure sinusoidal 230 V alternating voltage (AC) for
operation and stable power supply of connected
230 V consumers. In addition, when connected to
the mains, the device can be used to charge the
house battery or to support weak AC input sources
with additional energy (AC input current boost).
The inverter charger combination is suitable to
charge the following battery types:
Lead acid batteries
Lead gel batteries
Absorbed glass mat (AGM) batteries
LiFePO4 batteries
The inverter charger combination is not suitable to
charge other types of batteries (e.g. NiCd, NiMH,
etc.).
The inverter charger combination is suitable for:
Installation in recreational vehicles (RV)
Stationary or mobile use
Indoor use
The inverter charger combination is not suitable
for:
Outdoor use
This product is only suitable for the intended pur-
pose and application in accordance with these
instructions.
This manual provides information that is necessary
for proper installation and/or operation of the
product. Poor installation and/or improper operat-
ing or maintenance will result in unsatisfactory per-
formance and a possible failure.
The manufacturer accepts no liability for any injury
or damage to the product resulting from:
Incorrect assembly or connection, including
excess voltage
Incorrect maintenance or use of spare parts
other than original spare parts provided by the
manufacturer
Alterations to the product without express per-
mission from the manufacturer
Use for purposes other than those described in
this manual
Dometic reserves the right to change product
appearance and product specifications.
Technical des cription
General description
The inverter charger combination is a combination
of a DC-to-AC sine wave inverter with an inte-
grated battery charger.
If 230 V mains is available, this external power
source can be used both to supply the sockets in
the recreational vehicle and for charging the vehi-
cle battery.
If no 230 V mains is available, the inverter converts
the battery's direct current into alternating current,
thus ensuring the power supply for the connected
consumers.
The inverter charger combination offers the follow-
ing functions:
Automatic mains priority switching: Allows to
supply the AC sockets from different voltage
sources. If no 230 V mains is available, the
inverter can take over the supply of the sockets.
When 230 V mains are connected, the device
synchronizes and the AC sockets are then sup-
plied by the mains.
The electrical installation and setup of
the device must be performed by a qual-
ified electrician who has demonstrated
skill and knowledge related to the con-
struction and operation of electrical
equipment and installations, and who is
familiar with the applicable regulations
of the country in which the equipment is
to be installed and/or used, and has
received safety training to identify and
avoid the hazards involved.
4445103626 17
AC input current boost: Temporary support of
weak AC input sources with additional energy
from the house battery when high starting cur-
rents are needed (e.g. air conditioner) or the
connected load requires more power than is
available from the mains or a 230 V generator
Mains input current limitation: Limitation of the
230 V mains input to a maximum available cur-
rent
Power factor corrected mains input: Optimizing
energy efficiency and providing the maximum
possible charging current of the AC power
source with connected loads
• Microprocessor-controlled, temperature-com-
pensated IU0U charging programs for various
battery types
Integrated load detection: Automatic standby of
the inverter in case of prolonged non-use (after
10 minutes)
Automatic shutdown: Avoiding unnecessary
power consumption, the device automatically
switches off when no mains is available
The inverter charger combination has the follow-
ing protective mechanisms:
High battery voltage shutdown
Low battery voltage shutdown
Low input voltage protection
High input current protection
High temperature shutdown
Low temperature protection (only LiFePO4 bat-
teries)
Protection against short circuit
High ripple protection
The inverter charger combination can be adapted
to different battery types via DIP switches (see
chapter “Setting the charging program” on
page 23).
The temperature sensor monitors the battery tem-
perature during the charging process.
The inverter charger combination is equipped with
a remote control.
Description of the device
MT ICC 1600 SI-N
MT ICC 3000 SI-N
Item in
fig. 1,
page 3
Designation
1 Control panel
2 Inverter charger combination
3 Connection panel
4 Connection cable (5 m) with RJ45 plugs for
remote control
5 Temperature sensor with cable (3 m) and
RJ12 plug
6 Remote control
7 Wall mounting box for remote control
8 Switch for acoustic signal
9 Connected battery cable set (2 x 1.5 m/
35 mm2) with cable lugs (M8)
Item in
fig. 1,
page 3
Designation
1 Control panel
2 Inverter charger combination
3 Connection panel
4 Connection cable (5 m) with RJ45 plugs for
remote control
5 Temperature sensor with cable (3 m) and
RJ12 plug
6 Remote control
7 Wall mounting box for remote control
8 Switch for acoustic signal
9 Wall bracket
18 4445103626
Control panel on the device
Remote control
Power indication LEDs
Operating mode indication LEDs
Item in
fig. 3A,
page 4
Designation
1 Power indication LEDs
2 Operating mode indication LEDs
3 State of charge indication LEDs
(100 %, 80 %, 50 %, 0 %)
4 Switch (3-stage) for AC input current
limitation
Item in
fig. 3B,
page 4
Designation
1 Power indication LEDs
2 Operating mode indication LEDs
3 State of charge indication LEDs
(100 %, 80 %, 50 %, 0 %)
4 Operating mode selection button
(Pbutton)
Operating mode Description
Inverter operation Indication of output power deliv-
ered (in %)
Note: LED turns red when the
output power exceeds the
continuous output power value
(Pnom)
Mains operation Indication of momentary
charging current related to the
maximum charging current of
the device (in %)
LED Status Description
“Charger
ON”
(charger
on)
On (green) Mains operation
On (red) Charger deactivated
Flashing
(red)
Error (see chapter “Error
indication” on page 30)
Off No mains operation
“Inverter
ON”
(inverter
on)
On (green) Inverter operation (continu-
ous mode or mains sup-
port/ power boosting)
On (red) Inverter deactivated
Flashing
(green)
Inverter operation (auto-
matic mode or mains sup-
port/ power boosting)
Flashing
(red)
Error (see chapter “Error
indication” on page 30)
Off No inverter operation
“Line”
(AC input)
On (green) AC input approved, AC
transfer switch closed
On (red) AC transfer switch disabled
Flashing
(green)
AC input present and
within range, device
synchronizes
Flashing
(red)
AC input present but out of
range (see chapter “Error
indication” on page 30)
Off No AC input present, AC
transfer switch opened
4445103626 19
Battery charging function
The selectable charging programs (see chapter “Setting the charging program” on page 23) perform a
charging process in four phases, referred to as IU0U characteristics.
1: Constant current phase (Bulk)
The battery is constantly charged with the maxi-
mum charging current (100 %). The charging cur-
rent decreases when the battery has reached a
state of charge of 75 % (90 % for LiFePO4 batter-
ies). The duration of the constant current phase
depends on the condition of the battery, the load
from the DC loads and the state of charge.
2: Constant voltage phase (Absorption)
The constant voltage phase starts when the
absorption voltage (U1) is reached. The charging
current is reduced depending on the state of
charge. During the constant voltage phase, the
battery voltage is kept constant at a high level and
the state of charge is increased to 100 %. The dura-
tion of the constant voltage phase depends on the
battery type, but is terminated after a maximum of
4 h (absorption time-out).
3: Trickle charging phase (Float)
The trickle charging phase starts when the
charging current falls below a minimum value or
the absorption time-out has been reached.The
trickle charging phase serves to maintain the state
of charge (100 %) and runs at lowered charging
voltage (U2) and variable current. If DC loads are
connected, they are powered by the device.
If the power required exceeds the capacity of the
device, this surplus power is provided by the bat-
tery and the battery voltage drops. As soon as the
battery voltage has dropped to a certain value the
device re-enters the constant current phase and
charges the battery.
4: Reconditioning phase (Pulse)
Once a week, the device switches back to the con-
stant voltage phase for a short time (max. 1 h) in
order to revive the battery. This prevents any
fatigue phenomena such as sulfation or electrolyte
stratification.
Temperature sensor
With the temperature sensor connected the
inverter charger combination adapts the charging
voltage (for lead batteries) or the charging current
(for LiFePO4 batteries) according to the measured
temperature at the battery.
I
14
U (V) I (%)
12
10 100
50
10
5
0
2413
U
I
t
31
14,4
13,5
12,5
NOTE
Charging voltage adaptation:
30 mV/°C (referenced to 20 °C)
Charging current adaption:
Charging current reduction up to 10 %
of the maximum charging current (at
battery temperatures <0 °C) or to 0 %
(at battery temperatures >52 °C)
20 4445103626
Alarm relay (only MT ICC 1600 SI-N)
A
The alarm relay is activated as soon as the AC
power supply is available and the AC transfer
switch is closed. The alarm relay can be used to:
Generate an AC power supply detection sig-
nal in the vehicle control panel.
Switch on and off less critical loads (e.g.
absorber refrigerator, electrical heating sys-
tems) that should only be operated in connec-
tion with AC power supply.
Programmable relays
(only MT ICC 3000 SI-N)
A
The programmable relay 1 (Prog.Relay1) is acti-
vated as soon as the device detects an error (see
chapter “Error indication” on page 30). The pro-
grammable relay 1 can be used to generate an
error detection signal in the vehicle control
panel.
The programmable relay 2 (Prog.Relay2) is acti-
vated as soon as the AC power supply is avail-
able and the AC transfer switch is closed. The
programmable relay 2 can be used to:
Generate an AC power supply detection sig-
nal in the vehicle control panel.
Switch on and off less critical loads (e.g.
absorber refrigerator, electrical heating sys-
tems) that should only be operated in connec-
tion with AC power supply.
Activate or deactivate the auxiliary charging
output.
Trigger input
I
By factory default the trigger input closed or
bridged causes a delayed shutdown in the event of
a mains failure: The device initially switches to
inverter operation. Only when no mains is
detected at the AC input within 5 minutes, the
device switches off to avoid power consumption of
the house battery.
Additionally, the trigger input can be used for
external control of certain functions of the device,
e.g. to temporarily deactivate the AC input current
boost.
Mounting the inverter
charger combination
Installation location
A
I
Observe the following instructions when selecting
an installation location:
Ensure that the mounting surface is solid and
level.
Observe the distance specifications (fig. 5,
page 5).
MT ICC 1600 SI-N
1. Drill 4 holes according to the drilling template
(fig. 7, page 5).
2. Fasten the device with the mounting screws.
MT ICC 3000 SI-N
1. Drill 7 holes according to the drilling template
(fig. 8, page 5).
2. To mount the device, proceed as shown
(fig. 9, page 6).
NOTICE! Damage hazard
Ensure that the maximum relay contact
load is not exceeded to avoid damage to
the relay: 30 Vg/1 A or 60 Vg/0.3 A.
NOTICE! Damage hazard
Ensure that the maximum relay contact
load is not exceeded to avoid damage to
the relays: 30 Vg/16 A or 250 Vw/16 A
NOTE
For use of the default or additional func-
tions, the trigger input must be con-
nected (see chapter “Connecting the
trigger input” on page 23).
NOTICE! Damage hazard
Before drilling any holes, ensure that
no electrical cables or other parts of
the vehicle can be damaged by drill-
ing, sawing and filing.
Do not mount the device so that the
connections point upwards.
NOTE
The inverter charger combination can be
installed either sitting or hanging
(fig. 4, page 4).
1/196