SPX FLOW Viking Compact Användarmanual

Typ
Användarmanual
INSTRUCTION MANUAL
ORIGINAL INSTRUCTIONS/TRANSLATION OF ORIGINAL INSTRUCTIONS
READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS
PRODUCT
Viking Compact
MANUALLY OPERATED BILGE PUMP
IB-126 R04 (01/2016)
The Viking Compact manually operated bilge pump is in conformity with:
ISO 15083 Small Craft – Bilge pumping systems
Made in China
Garanti 2 år
Warranty 2 years
Garantie 2 Jahren
Garantie 2 ans
Garantía 2 años
Garanzia 2 anni
INDEX INDICE
Svenska ............................................................................................................. 3
English .............................................................................................................. 7
Deutsch ...........................................................................................................11
Figures ............................................................................................................. 16
Français ...........................................................................................................22
Español ............................................................................................................26
Italiano .............................................................................................................30
Besök www.johnson-pump.com för mer information om vår världsomspännande organisation, våra godkännanden, certifieringar och lokala representanter.
SPX FLOW, Inc. förbehåller sig rätten att ändra design och material utan föregående avisering. Designelement, konstruktionsmaterial och dimensioner som
beskrivs i denna bulletin gäller endast som information och skall alltid bekräftas skriftligt för att vara gällande.
For more information about our worldwide locations, approvals, certifications, and local representatives, please visit www.johnson-pump.com. SPX FLOW,
Inc. reserves the right to incorporate our latest design and material changes without notice or obligation. Design features, materials of construction and
dimensional data, as described in this bulletin, are provided for your information only and should not be relied upon unless confirmed in writing.
Für weitere Informationen über unsere weltweiten Standorte, Zulassungen, Zertifizierungen und unsere Vertreter vor Ort, besuchen Sie bitte unsere
Webseite: www.johnson-pump.com. Die SPX FLOW, Inc. behält sich das Recht vor, die neuesten Konstruktions- und Werkstoffänderungen ohne
vorherige Ankündigung und ohne Verpflichtung hierzu einfließen zu lassen. Konstruktive Ausgestaltungen, Werkstoffe sowie Maßangaben, wie sie in
dieser Mitteilung beschrieben sind, sind nur zur Information. Alle Angaben sind unverbindlich, es sei denn, sie wurden schriftlich bestätigt.
Pour plus d’information sur nos succursales internationales, nos approbations, nos certifications et nos représentants locaux, veuillez consulter notre
site Internet au www.johnson-pump.com. SPX FLOW, Inc. se réserve le droit d’incorporer nos plus récents concepts ainsi que tout autre modification
importante sans préavis ou obligation. Les éléments décoratifs, matériaux de construction et les données dimensionnelles, tels qu’énoncés dans ce
communiqué, sont fournis pour votre information seulement et ne doivent pas être considérés comme officiels à moins d’avis contraire par écrit.
Para más información sobre nuestras oficinas a nivel mundial, aprobaciones, certificaciones y representantes locales, por favor visite
www.johnson-pump.com. SPX FLOW, Inc. se reserva el derecho de incorporar nuestro diseño más reciente y cambios materiales sin necesidad de
notificación previa u obligación de ningún tipo. Características de diseño, materiales de construcción y dimensiones, tal y como están descritas en este
boletín, son proporcionadas sólo con fines informativos y no deben ser usados como referencia a menos que sean confirmados por escrito.
Per ottenere maggiori informazioni sulle nostre sedi nel mondo, autorizzazioni, certificazioni, e rappresentanti locali, potete visitare il sito
www.johnson-pump.com. La SPX FLOW, Inc. si riserva il diritto di apportare cambiamenti ai propri design e materiali senza preavviso o vincolo. Le
caratteristiche del design, i materiali di costruzione e i dati dimensionali, così come descritti nel presente bollettino, sono forniti solo per vostra
informazione e non saranno oggetto di obbligazione salvo autorizzazione confermata per iscritto.
Översättning av originalinstruktionerna
> Svenska
The Viking Compact manually operated bilge pump is in conformity with:
ISO 15083 Small Craft – Bilge pumping systems
Made in China
Garanti 2 år
Warranty 2 years
Garantie 2 Jahren
Garantie 2 ans
Garantía 2 años
Garanzia 2 anni
Manuell länspump
Typiska användningsområden
Viking Compact är en självsugande membranpump avsedd som länspump i båtar. Viking Compact
och dess installationer överensstämmer med ”ISO 15083 Small craft – Bilge pumping systems”.
VikingCompact kan användas för båtar enligt designkategori A, B, C och D med skrovlängder
större än 12 meter, allt enligt ISO 15083.
Teknisk beskrivning
Plastmaterial: ABS, PA 66, PP
Elastomer: Nitrilgummi
Metalldelar: Rostfritt stål
Anslutningar: 25 mm (1") eller 38 mm (1 ½") slanganslutningar.
Max. vätsketemp.: +60°C (140°F)
Lagringstemp.: -40°C till +60°C (-40°F till 140°F), förutsatt att pumpen ej används
och att den ej är vätskefylld.
Dimensioner: Se fig. 1.
Vikt: 0,7 kg (1.54 lbs)
Modellspecifikation
Typ Artikelnr.
Viking Compact m. anslutningsdia. 25 mm (1") och 38 mm (1½").
Konsumentförpackning
10-24800-01
Viking Compact m. anslutningsdia. 25 mm (1").
Bulkförpackning
10-24800-11
Viking Compact m. anslutningsdia. 38 mm (1½").
Bulkförpackning
10-24800-10
Viking Compact m. anslutningsdia. 25mm (1") och 38 mm (1½").
Bulkförpackning
10-24800-12
Prestanda
Pumpens flöde är beroende av installation och antalet slag per minut.
Prestanda vid 1 meters lyfthöjd (10 kPa tryck) och 45 slag per minut.
Anslutningsdia. 38 mm (1½") 45 l/min (11.9 USGPM)
Anslutningsdia. 25 mm (1") 34.5 l/min (9.11 USGPM)
Max sughöjd 2,1 m / 7 feet
Max lyfthöjd (efter pump) 1,2 m / 4 feet
Max sammanlagd sug- och lyfthöjd 3,3 meters / 11 feet.
3
Översättning av originalinstruktionerna
> Svenska
Innan installation
• Exempel på typisk pumpinstallation, se fig. 2.
• För installation i båtar av kategorierna A, B och C, skall pumpen placeras så att den kan nås och
användas från platsen vid styrpulpeten.
• Försäkra dig om att det finns tillräckligt med plats för pumpen bakom skott eller under däck.
Se fig 1.
• Försäkra dig om att det finns tillräckligt med plats att manövrera pumpen då dess lock/handtag är
fullt utfällt. Se fig 1.
• Placeringen av pumpens in- och utloppsanslutningar med ventiler kan växlas, för att ändra
flödesriktningen. (Det är dock viktigt att inloppsventilen följer inloppsanslutningen, och att
utloppsventilen följer utloppsanslutningen).
• Välj en plan yta för placeringen av Viking Compact.
• Installationen skall utföras i enlighet med ”ISO 15083 Small craft – Bilge pumping systems”
Montering
• Tag upp ett cirkulärt hål med diameter 140 mm och borra fyra hål för fästskruvarna. Använd bifogat
hålschema. Se fig 3.
• Tag bort slanganslutningarna från pumpen genom att lossa låsclipsen. Fäst anslutningarna i resp.
slang, och drag åt slangklämmorna. Använd slangklämmor av icke rostande material.
• För att ge plats för åtdragning av de två fästskruvarna närmast gångjärnet, frigör locket från
pumpens basplatta genom att pressa ut axeln vid gångjärnet (pos. 11). Notera att axeln endast
kan pressas genom låsbrickan i en riktning, se fig. 4. Notera låsbrickans läge för den senare
återmonteringen.
• Återmontera slanganslutningarna med slangar i dess lägen i pumphuset. Var uppmärksam på att
ventilerna kommer i rätt läge och att rätt ventil hamnar tillsammans med rätt anslutning.
• Klaffventilen är för inloppet och den konformade ventilen är för utloppet.
• Lås därefter anslutningarna med låsclipsen.
• För sedan in pumpen med slangar i dess läge i båten. Försäkra dig om att packningen kommer i
rätt läge.
• Drag åt de fyra fästskruvarna. Använd 5mm självgängande rostfria skruvar med försänkt huvud.
• Sätt tillbaka locket i basplattan genom att skjuta i axeln i gångjärn och låsbricka. Notera att axeln
endast kan pressas genom låsbrickan i en riktning. Se fig. 4.
Viktigt!
• Använd alltid sil på inloppsslangen för att undvika att få in skräp i pumpen.
• Bordgenomföringen i skrovet skall alltid placeras ovanför högsta vattenlinjen.
• Använd icke kollapsande (förstärkt) slang på pumpens sugsida
Drift
• Pumpen manövreras med hjälp av locket/handtaget.
• Efter länsning, fortsätt tills pumpen suger luft. Skjut därefter ned locket/handtaget i låst läge.
Varning!
• Använd aldrig pumpen för lättantändliga eller aggressiva vätskor.
• Använd aldrig en frusen pump.
• Låt aldrig vassa partiklar komma in i pumpen då de kan skada membranet.
• Kapaciteten hos denna pump är ej avsedd att klara katastrofsituationer, ex.vis skador på skrovet.
4
Översättning av originalinstruktionerna
> Svenska
Vinterförvaring
För att undvika frysskador, töm pump och ledningar från vatten vid frostrisk.
Använd aldrig en frusen pump.
Underhåll
Regelbunden inspektion av pumpen rekommenderas. Kontrollera pumpens funktion.
Gör rent inloppssilen från föroreningar.
Gummikomponenter skall bytas då de är slitna eller minst vart tredje år.
Servicesats nr. 09-47440 Membran, in- och utloppsventiler, 2 st O-ringar och 2 st låsbrickor.
Servicesats nr. 09-47441 Lock, 2 st axlar och 2 st låsbrickor
Byte av membran
För positionreferenser, se fig. 5.
• Pressa ur gångjärnets axel (pos 11) och axeln (pos 11) som förbinder membran och lock. Axeln
kan endast pressas i en riktning genom låsbrickan, se fig. 4. Notera låsbrickans läge för senare
återmontering.
• Lossa de fyra fästskruvarna, lyft ut pumpen ur dess läge. Lossa anslutningarna, (pos. 9 och 10),
genom att dra ut låsclipsen.
• Vrid pumphuset, (pos. 3) i förhållande till basplattan (pos. 4). Lyft pumphus och membran ur bas-
plattan.
• By ut membranet (pos.2). Placera den lilla knoppen på membranet mot märkningen på pumphuset.
Smörj innerdiametern/läget för membranet i basplattan med flytande tvål.
• Placera pumphuset (pos.3) tillsammans med det nya membranet (pos 2) i basplattan (pos. 4), tryck
nedåt och vrid tills du når stoppet.
• Byt ut ventilerna (pos. 6 och 7) i de två anslutningarna. Förvissa dig om att varje ventil kommer i rätt
läge. Klaffventilen är för inloppet och den konformade ventilen är för utloppet. Notera att texten på
inloppsventilen skall vändas mot membranet. Sätt tillbaka anslutningarna i pumphuset. Lås anslut-
ningarna genom att trycka in låsclipsen. (pos. 13).
• Sätt tillbaka pumpen i sitt läge i båten. Drag åt de fyra fästskruvarna.
• Montera de två axlarna (pos. 11), den ena mellan membran och lock och den andra i gångjärnet.
Pressa axeln genom låsbrickan, (pos. 12). Se till att låsbrickan kommer i rätt läge. Notera att axeln
endast kan pressas genom låsbrickan i en riktning. Se fig. 4.
Byte av ventiler
För positionsreferenser, se fig. 5
• Tag bort pump från dess läge.
• Lossa anslutningarna (pos. 9 och 10) genom att dra ut de röda låsclipsen (pos. 13).
• Byt ut ventilerna (pos. 6 och 7) i de två anslutningarna. Förvissa Dig om att varje ventil kommer i
rätt läge. Klaffventilen är för inloppet och den konformade ventilen är för utloppet. Notera att texten
på inloppsventilen skall vändas mot membranet. Sätt tillbaka anslutningarna i pumphuset. Lås
anslutningarna genom att trycka in låsclipsen (pos. 13).
• Återmontera pumpen
5
Översättning av originalinstruktionerna
> Svenska
Avfallshantering / Materialåtervinning
Vid avfallshantering skall produkten lämnas för destruktion/återvinning enligt gällande lagstiftning. Vid
tillämpliga fall demonteras och sorteras produkten i ingående materialfraktioner.
Förteckning över pumpens delar och material
För positionsreferenser, se fig. 5
Pos. Art. Nr. Beskrivning Material
1 01-24798 Lock ABS
2 01-24799 Membran Nitrilgummi
301-24797 Pumphus Polypropylene
4 01-24796 Basplatta ABS
5 01-47393 Packning Nitrilgummi
6 01-47385 Utloppsventil Nitrilgummi
701-47386 Inloppsventil Nitrilgummi
8 0.2173.211 O-ring Nitrilgummi
9 01-36178-1 Slanganslutning för utlopp,
dia 38mm
PA 66
01-36178-3 Slanganslutning för utlopp,
dia 25mm
PA 66
10 01-36179-1 Slanganslutning för inlopp,
dia 38 mm
PA 66
01-36179-3 Slanganslutning för inlopp,
dia 25 mm
PA 66
11 01-47387 Axel Rostfritt stål
12 0.0357.003 Låsbricka Rostfritt stål
13 01-47388 Låsclips PA 66
14 01-46688-2 Etikett PETP
6
Original instructions
> English
Manually operated bilge pump
Typical applications
Viking Compact is a manually operated, self priming, diaphragm pump designed for bilge pump
applications on boats. The Viking Compact pump and its installation complies with ”ISO 15083 Small
craft – Bilge pumping systems”. Viking Compact pump can be used on boats of design categories
A, B, C and D, according to ISO 15083 with hull length greater than 12 m (59 ft).
Design features
Plastic materials: ABS, PA 66, PP
Elastomers: Nitrile rubber
Shafts: Stainless steel
Connections: 25 mm (1") or 38 mm (1 ½") hose connections.
Max. liquid temp.: +60°C (140°F)
Storage temp.: -40°C to +60°C (-40°F to 140°F), without operation and in dry condition.
Dimensions: According to fig.1.
Weight: 0,7 kg (1.54 lbs)
Model Specifications
Type Article no.
Viking Compact w. dia. 25 mm (1") and dia. 38 mm (1½") ports.
Individual packing
10-24800-01
Viking Compact w. dia. 25 mm (1") ports.
Bulk packing
10-24800-11
Viking Compact w. dia. 38 mm (1½") ports.
Bulk packing
10-24800-10
Viking Compact w. dia. 25mm (1") and dia. 38 mm (1½") ports.
Bulk Packing
10-24800-12
Capacity
Output capacity depends on installation conditions and pumping rate.
Performance given at back pressure (head) of 10 kPa (1.45 psi) rated for 45 strokes per minute:
Dia. 38 mm (1½") ports 45 l/min (11.9 USGPM)
Dia. 25 mm (1") ports 34.5 l/min (9.11 USGPM)
Maximum lift 2,1 m / 7 feet
Maximum head 1,2 m / 4 feet
Maximum combined lift and head 3,3 meters / 11 feet.
7
Original instructions
> English
Before installation
• Typical installation, see fig. 2.
• For crafts in design categories A, B and C, pump should be located operateable from steering
position.
• Make sure that there is enough room behind bulkhead or under deck for full depth of pump when
installed. See figure 1.
• Ensure that there is enough space available when pump is installed in order to operate pump with
its handle fully open. See figure 1.
• Position of inlet and outlet ports and valves in pump body may be changed. (It is most important
that inlet valve is matched with inlet port and outlet valve is combined with outlet port.)
• Select a suitable flat area for the location of Viking Compact pump.
• Installation should be compliable with ”ISO 15083 Small Craft – Bilge pumping systems”
Mounting
• Cut a circular hole dia. 140 mm (5½") for the pump and drill 4 holes for the fastening screws. Use
enclosed hole layout. See fig. 3.
• Remove the elbows from the pump by releasing the clips. Fit the elbows to the hoses and secure
them with non-corrosive type of hose clamps.
• In order to tighten the two screws near the hinge, release the cover from the base by pressing out
the pin (pos 11). Note that the pin can only be pressed through lock washer in one direction, see
fig. 4. Note the location of the lock washers for later reassembly.
• Reassemble ports and hoses to the pump body. Be careful that each valve is in the proper position.
Be sure that correct valve is installed with the correct port.
• Flap valve is for inlet and tricuspid valve is for outlet.
• Lock the elbows with the clips.
• Insert pump with hoses in its location. Secure the gasket position.
• Fasten the 4 screws. Use dia. 5 mm self tapping stainless steel screws with round countersunk
head.
• Reconnect cover to diaphragm, by reassembly of pin and lock washer. Note that the pin can only
be pressed through lock washer in one direction, see fig. 4.
Note!
• Alwaysusewaterinletstrainertoavoiddebriscloggingthepump.
• Outletsonhullshallbelocatedabovemaximumheeledwaterline.
• Alwaysusenoncollapsing(reinforced)hoseonsuctionsideofpump.
Operation
• Operate pump by the cover/handle.
• After use operate the pump until it sucks air, then firmly push the cover into the closed position.
Caution!
• Never use the pump for any flammable or hazardous liquids
• Never operate a frozen pump.
• Never let sharp particles enter pump which can cut the diaphragm.
• Capacity of this pump system is not intended to drain the craft in case of damage.
8
Original instructions
> English
Winterization
To avoid damage from freezing, drain pump and all pipe work of water.
Never operate a frozen pump.
Maintenance
Regular inspection of pump is recommended. Check the function of the pump.
Clear debris from pump inlet.
Rubber components should be replaced if worn or every three years.
Service kit no. 09-47440 Diaphragm, inlet- and outlet valves 2 pcs o-rings and 2 pcs lock
washers
Service kit no 09-47441 Cover, 2 pcs pins and 2 pcs lock washers
Diaphragm replacement
For position reference see fig. 5
• Press the hinge pin (pos 11) and the pin (pos11) connecting diaphragm and cover out of their
positions. Due to the lock washers (pos 12) it is only possible to move the pins in one direction,
see fig. 4. Be careful not to lose the two lock washers. Note the location of the lock washers for
later reassembly.
• Remove the 4 fixing screws, lift pump out from bulkhead or deck. Disconnect the elbows (pos 9
and 10) by pulling open the red clips (pos 13).
• Twist the pump body (pos 3) in relation to the base (pos 4). Lift the pump body and diaphragm out
of the base.
• Replace the diaphragm (pos 2). Align the small knob on the diaphragm with the mark on the pump
body. Lubricate the inner diameter of the base with some liquid soap.
• Put the pump body (pos 3) together with the new diaphragm (pos 2) in the base (pos 4) and twist
until you reach the stop.
• Replace the valves (pos 6 and 7) in the ports. Be careful that each valve get its proper position. Be
sure that correct valve is installed with the correct port. Flap valve (pos 7) is for inlet and tricuspid
valve (pos 6) is for outlet. The text of the inlet valve (flap valve) should be turned against the
diaphragm. Relocate the elbows. Lock the elbows with the clips (pos 13).
• Relocate the pump in its position in the boat. Attach it with the 4 fixing screws.
• Reassemble the two pins (pos 11); one connecting diaphragm and cover and one for the hinge.
Press the pins through the lock washers (pos 12). Note the position of the lock washers. Note that
the pin can only be pressed through lock washer in one direction, see fig. 4.
Valve replacement
For position reference see fig. 5
• Remove pump from bulkhead or deck (see instructions above).
• Disconnect the elbows (pos 9 and 10) by pulling open the red clips (pos 13) together with the
hoses from the pump.
• Replace the valves (pos 6 and 7) in the ports. Be careful that each valve is placed in its proper
position. Be sure that correct valve is installed with the correct port.The flap valve (pos 7) is for inlet
and the tricuspid valve (pos 6) is for outlet. The text on the inlet valve (flap valve) should be turned
against the diaphragm. Relocate the elbows. Lock the elbows with the clips (pos 13).
• Re-mount the pump as per previous mounting instructions.
9
Original instructions
> English
Waste management / Recycling
Dispose of the product in accordance with existing regulations.
Where appropriate, dismantle and sort the product by its material fractions.
Part and material list
For position reference see fig. 5
Pos. Part no Description Material
1 01-24798 Cover ABS
2 01-24799 Membrane Nitrile rubber
301-24797 Pump body Polypropylene
4 01-24796 Base ABS
5 01-47393 Sealing Nitrile rubber
6 01-47385 Outlet valve Nitrile rubber
701-47386 Inlet valve Nitrile rubber
8 0.2173.211 O-ring Nitrile rubber
9 01-36178-1 Outlet connection dia 38mm PA 66
01-36178-3 Outlet connection dia 25mm PA 66
10 01-36179-1 Inlet connection dia 38 mm PA 66
01-36179-3 Inlet connection dia 25 mm PA 66
11 01-47387 Pin Stainless steel
12 0.0357.003 Lock washer Stainless steel
13 01-47388 Clip PA 66
14 01-46688-2 Label PETP
10
Übersetzung der Original-Betriebanleitungen
> Deutsch
Manuelle Bilgenpumpe
Typische Anwendungen
Die Viking Compact ist eine manuell betriebene selbstansaugende Membranpumpe für
Lenzeinrichtungen auf Booten. Die Viking Compact Pumpe und ihre Installation erfüllen die
Anforderungen des ”ISO 15083 Small craft – Bilge pumping systems”. Die Viking Compact Pumpe
kann auf Booten der Kategorien A, B, C und D mit einer Rumpflänge über 12 m (59 ft) nach ISO15083
verwendet werden.
Ausführung
Kunststoffmaterialien: ABS, PA 66, PP
Elastomere: Nitrilgummi
Wellen: Edelstahl
Anschlüsse: 25 mm (1") oder 38 mm (1 ½") Schlauchanschlüsse.
Max Flüssigkeitstemp.: +60°C (140°F)
Lagerungstemp.: -40°C bis +60°C (-40°F to 140°F), ohne Betrieb und in trockenen
Bedingungen.
Abmessungen: Aufgrund Abb. 1.
Gewicht: 0,7 kg (1.54 lbs)
Technische Beschreibungen der Ausführungen
Typ Artikelnummer
Viking Compact mit Anschluss 25 mm (1") und 38 mm (1½").
Einzelnverpackung
10-24800-01
Viking Compact mit Anschluss 25 mm (1").
Mehrverpackung
10-24800-11
Viking Compact mit Anschluss 38 mm (1½").
Mehrverpackung
10-24800-10
Viking Compact mit Anschluss 25mm (1") und 38 mm (1½").
Mehrverpackung
10-24800-12
Leistung
Die Leistung der Pumpe hängt von den Installationsbedingungen und der Pumpgeschwindigkeit ab.
Die Leistungsangaben gelten für einen Gegendruck (Förderhöhe) von 10 kPa (1,45 psi)
bei 45 Hüben pro Minute:
Stutzendurchmesser 38 mm (1½") 45 l/min (11.9 USGPM)
Stutzendurchmesser 25 mm (1") 34.5 l/min (9.11 USGPM)
Max. Saughöhe 2,1 Meter / 7 Fuß
Max. Förderhöhe 1,2 Meter / 4 Fuß
Max. kombinierter Saug- und Förderhöhe 3,3 Meter / 11 Fuß.
11
Übersetzung der Original-Betriebanleitungen
> Deutsch
Vor der Installation
• Zur typischen Installation siehe Abb. 2.
• Bei Schiffen der Kategorien A, B und C soll die Pumpe von der Steuerung betreibbar sein.
• Stellen Sie beim Installieren sicher, dass es genug Platz für die volle Tiefe der Pumpe hinter der
Kabinendecke oder unter dem Deck gibt. Siehe Abb. 1.
• Stellen Sie bei der Installation sicher, dass es genug Platz für den Betrieb der Pumpe mit ganz
geöffnetem Handgriff gibt. Siehe Abb. 1.
• Die Stellung der Ein- und Ausgangsstutzen und Ventile kann im Pumpengehäuse geändert werden.
(Am wichtigsten ist, dass das Eingangsventil mit dem Eingangsstutzen und das Ausgangsventil mit
dem Ausgangsstutzen übereinstimmen.)
• Wählen Sie für die Viking Compact Pumpe eine geeignete ebene Stelle.
• Die Installation soll die Anforderungen des ”ISO 15083 Small Craft – Bilge pumping systems”
erfüllen
Montage
• Schneiden Sie eine runde Öffnung mit einem Durchmesser von 140 mm (5½”) für die Pumpe
und bohren Sie 4 Bohrungen zur Befestigung der Schrauben. Verwenden Sie das beigefügte
Bohrmuster. Siehe Abb. 3.
• Entfernen Sie die Kniestücke von der Pumpe, indem Sie die Klemmen lösen. Bringen Sie die
Kniestücke an die Schläuche und befestigen Sie sie mit nichtkorrodierenden Schlauchklemmen.
• Zum Anziehen der zwei Schrauben in der Nähe des Gelenks lösen Sie den Deckel vom
Sockel, indem Sie den Bolzen (Pos. 11) ausdrücken. Der Bolzen kann nur in einer Richtung
durch die Sicherungsscheibe gedrückt werden, siehe Abb. 4. Beachten Sie die Stellung der
Sicherungsscheiben für die spätere Montage.
• Montieren Sie die Stutzen und die Schläuche an den Pumpengehäuse. Stellen Sie sicher, dass
sich jedes Ventil in richtiger Stellung befindet. Stellen Sie sicher, dass die Ventile zu richtigen
Stutzen montiert werden.
• Das Klappventil ist für den Einlass und die Trikuspidalklappe für den Auslass bestimmt.
• Verriegeln Sie die Kniestücke mit Klemmen.
• Stellen Sie die Pumpe mit den Schläuchen in ihren Einsatzort. Fixieren Sie die Stellung der
Dichtung.
• Befestigen Sie die 4 Schrauben. Verwenden Sie die 5 mm Edelstahl-Blechschrauben mit rundem
Senkkopf.
• Schließen Sie den Deckel wieder an den Sockel, indem Sie den Bolzen und die Sicherungsscheibe
wieder montieren. Der Bolzen kann nur in einer Richtung durch die Sicherungsschraube gedrückt
werden, siehe Abb. 4.
Hinweis!
• Verwenden Sie im Eingang immer einen Wasserfilter, um eine Verstopfung der Pumpe mit Schmutz
zu vermeiden.
• Die Ausgänge am Schiffsrumpf müssen sich über der maximal gekrängten Wasserlinie befinden.
• Verwenden Sie an der Ansaugseite der Pumpe immer einen nicht-einknickenden Schlauch
Betrieb
• Betreiben Sie die Pumpe über den Deckel/Handgriff.
• Nach dem Einsatz betreiben Sie die Pumpe, bis sie Luft ansaugt, und drücken Sie den Deckel
danach fest in geschlossene Stellung.
Vorsicht!
• Verwenden Sie die Pumpe nie für entzündliche oder gefährliche Flüssigkeiten.
• Betrieben Sie nie eine eingefrorene Pumpe.
• Scharfe Partikel dürfen nie in die Pumpe gelangen, da sie die Membrane beschädigen können.
• Die Leistung der Pumpe reicht nicht für die Entwässerung des Bootes bei Beschädigungen aus.
12
Übersetzung der Original-Betriebanleitungen
> Deutsch
Winterfest machen
Um Kältebeschädigungen zu vermeiden, entleeren Sie die Pumpe und die Rohre vom Wasser.
Betrieben Sie nie eine eingefrorene Pumpe.
Wartung
Die Pumpe soll regelmäßig überprüft werden. Überprüfen Sie die Funktion der Pumpe.
Entfernen Sie den Schmutz vom Pumpeneinlass.
Verschlissene Gummikomponenten müssen ersetzt werden, mindestens jedoch alle drei Jahre.
Wartungssatz Nr. 09-47440 Membran, Ein- und Ausgangsventile, 2 O-Ringe und
2 Sicherungsscheiben
Wartungssatz Nr. 09-47441 Deckel, 2 Bolzen und 2 Sicherungsscheiben
Membrane ersetzen
Zur Stellungen sehen Sie Abb. 5
• Drücken Sie den Gelenkbolzen (Pos. 11) und den Bolzen (Pos. 11) zwischen der Membrane und
dem Deckel aus ihren Stellungen. Wegen der Sicherungsscheiben (Pos. 12) können die Bol-
zen nur in einer Richtung bewegt werden, siehe Abb. 4. Seien Sie vorsichtig, damit Sie die zwei
Sicherungsscheiben nicht verlieren. Achten Sie auf die Stellung der Sicherungsscheiben, um sie
später wieder montieren zu können.
• Entfernen Sie die 4 Sicherungsschrauben und heben Sie die Pumpe aus der Kabinendecke oder
dem Deck. Lösen Sie die Kniestücke (Pos. 9 und 10), indem Sie die roten Klemmen aufziehen (Pos.
13).
• Drehen Sie den Pumpengehäuse (Pos. 3) in Bezug auf den Sockel (Pos. 4). Heben Sie den Pum-
pengehäuse und die Membrane aus dem Sockel.
• Ersetzen Sie die Membrane (Pos. 2). Richten Sie den kleinen Kopf auf der Membrane zum Zeichen
auf dem Pumpengehäuse aus. Schmieren Sie den Innendurchmesser des Sockels mit etwas Flüs-
sigseife.
• Legen Sie den Pumpengehäuse (Pos. 3) mit der neuen Membrane (Pos. 2) auf den Sockel (Pos.4)
und drehen Sie sie bis zum Anschlag.
• Ersetzen Sie die Ventile (Pos. 6 und 7) in den Stutzen. Stellen Sie sicher, dass jedes Ventil die
richtige Stellung erreicht. Stellen Sie sicher, dass das Ventil mit dem korrekten Stutzen installiert
wird. Das Klappventil (Pos. 7) ist für den Einlass und die Trikuspidalklappe (Pos. 6) für den Auslass
bestimmt. Der Text auf dem Einlassventil (Klappventil) sollte gegen die Membrane gedreht werden.
Legen Sie die Kniestücke zurück. Verriegeln Sie die Kniestücke mit Klemmen (Pos. 13).
• Legen Sie die Pumpe in ihre Stellung im Boot zurück. Befestigen Sie die Pumpe mit 4 Sicherungs-
schrauben.
• Montieren Sie die zwei Bolzen (Pos. 11) wieder zusammen: einen an die Membrane und den
anderen an das Gelenk. Drücken Sie die Bolzen durch die Sicherungsscheiben (Pos. 12). Achten
Sie auf die Stellung der Sicherungsscheiben. Der Bolzen kann nur in einer Richtung durch die
Sicherungsschraube gedrückt werden, siehe Abb. 4.
13
Übersetzung der Original-Betriebanleitungen
> Deutsch
Ventile ersetzen
Zu Stellung sehen Sie Abb. 5
• Entfernen Sie die Pumpe von der Kabinendecke oder vom Deck (siehe Anweisungen oben).
• Lösen Sie die Kniestücke (Pos. 9 und 10) zusammen mit den Schläuchen von der Pumpe, indem
Sie die roten Klemmen aufziehen (Pos. 13).
• Ersetzen Sie die Ventile (Pos. 6 und 7) in den Stutzen. Stellen Sie sicher, dass jedes Ventil sich in
richtiger Stellung befindet. Stellen Sie sicher, dass das Ventil mit dem korrekten Stutzen installiert
wird. Das Klappventil (Pos. 7) ist für den Einlass und die Trikuspidalklappe (Pos. 6) für den Auslass
bestimmt. Der Text auf dem Einlassventil (Klappventil) sollte gegen die Membrane gedreht werden.
Legen Sie die Kniestücke zurück. Verriegeln Sie die Kniestücke mit Klemmen (Pos. 13).
• Montieren Sie die Pumpe aufgrund der vorherigen Montageanweisungen.
Abfallbehandlung/Recycling
Entsorgen Sie das Produkt nach gültigen Vorschriften.
Bei Bedarf demontieren Sie das Produkt und sortieren Sie es aufgrund Materialarten.
Teile- und Materialliste
Zu Stellung sehen Sie Abb. 5
Pos. Part no Description Material
1 01-24798 Deckel ABS
2 01-24799 Membrane Nitrile rubber
301-24797 Pumpengehäuse Polypropylene
4 01-24796 Sockel ABS
5 01-47393 Dichtung Nitrile rubber
6 01-47385 Ausgangsventil Nitrile rubber
701-47386 Eingangsventil Nitrile rubber
8 0.2173.211 O-Ring Nitrile rubber
9 01-36178-1 Auslassanschluss, Durchm. 38 mm PA 66
01-36178-3 Auslassanschluss, Durchm. 25mm PA 66
10 01-36179-1 Eingangsanschluss, Durchm. 38 mm PA 66
01-36179-3 Eingangsanschluss, Durchm. 25 mm PA 66
11 01-47387 Bolzen Stainless steel
12 0.0357.003 Sicherungsscheibe Stainless steel
13 01-47388 Klemme PA 66
14 01-46688-2 Schild PETP
14
15
178
28 Ø38 = 121, Ø25 = 115
Ø140
210
160
Ø38 / Ø25
Fig. 1
> Figures
16
< 3m
Fig. 2
> Figures
17
66 66
132
85
Ø
140
Ø5,5 (4x)
> Figures
18
66 66
132
85
Ø
140
Ø5,5 (4x)
> Figures
Fig. 3
19
> Figures
12
11
Tryck i den här riktningen
Pressing direction
Druckrichtung
Direction de la poussée
Dirección de presionado
Direzione di spinta
Fig. 4
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

SPX FLOW Viking Compact Användarmanual

Typ
Användarmanual