5019 318 33101
AKR 400 - 404 - 405 - 410 - 437 - 501 - 521
AKR 645 - 934 - 417 - 948 - 961 - 978
PRODUCT SHEET
1.
Control panel.
2.
Self-supporting grease filters
(depending on model).
3.
Extractor grille with internal grease filter
(depending on model).
4.
Lighting unit.
Replacing bulbs
1.
Disconnect the electrical power supply.
2.
Open the extractor grille or remove the self-
supporting grease filter (depending on model).
Fig. 1 (a-b)
.
3.
Remove the burnt-out bulb.
Replace using 40 W max E14 bulbs only.
4.
Refit the extractor grille or grease filter.
Only for model equipped with halogen bulbs
Use a small screwdriver or any other suitable tool to
prise off
(m-Fig. 3)
the lamp cover
(p-Fig. 3).
Replace the damaged bulb.
Use 20 W max halogen bulbs only, making sure not to
touch them with your hands. Close the lighting unit
(snap-close).
Fitting or renewing the carbon filter:
1.
Disconnect the electrical power supply.
2.
Open the extractor grille or remove the self-
supporting grease filter (depending on model).
Fig. 1 (a-b)
.
3.
To access the carbon filter seat, rotate the knobs
90° and open the lid.
Fig. 2 (c)
.
4.
Fit the shaped carbon filter in its default
location.
Fig. 2 (d)
.
5.
Turn the carbon filter locking knob 90° (check
that the filter is secured, otherwise rotate it
further).
Fig. 2 (e)
.
6.
Close the carbon filter compartment
7.
Refit the extractor grille or grease filter.
To remove the carbon filter, proceed in reverse order.
Grease filter maintenance:
1.
Disconnect the electrical power supply.
2.
Open the extractor grille or remove the self-
supporting grease filter (in this last case wash
the filter immediately).
Fig. 1 (a-b).
3.
Remove the device securing the grease filter.
4.
Remove the dirty grease filter.
5.
After the grease filter has been replaced or
cleaned (depending on model), refit the parts in
reverse order, making sure the entire extraction
surface is covered.
CONTROL PANEL
Light switch.
The switch has two positions
(lights OFF - lights ON).
To switch on the lights: move the switch to the
right.
Extraction speed selection switch.
The extraction speed switch has different
settings, depending on the amount of steam and
fumes.
To increase the extraction speed: move the
switch to the right.
Valve open/close switch
(only AKR 645):
move the switch to the right to
open the valve and extract steam and fumes (the
hood must be connected to a peripheric extractor
unit).
Fig. 3
Fig. 1
Fig. 2
S N
DK FIN GB
31833101.fm Page 7 Friday, November 7, 2003 12:10 PM