CTC EcoAir 105-111 (v.3) - electronic defrosting
Exchange instruction, display card
!
The connection of cables must be performed by an authorized installation technician.
Make sure to disconnect the power supply to the unit (phases and ground connections) be-
fore starting to work.
162 401 50-2 2017-11-28
Terminal G,
display card
Terminal F,
display card
Connection box
Terminal X1
EcoAir105 -111 and Polar edition
up to s/n: 7312-0806
EcoAir105 -111 and Polar edition
from s/n: 7312-0806 up to s/n: 7312-1023
1. Start by transferring the cables from the old display card
to the new card. Start with connection G1 and then
transfer all cables of terminal G.
When all cables have been transferred, there will be four
spare connections at the top of the terminal (G17-G20).
2. In the same way, transfer the cables of terminal F from
the old display card to the new card.
Start with connection F1 and then transfer the other
cables. Connection F9 will then be empty.
3. Remove cable 11 from the defrosting device and attach
it to connection F9 on the display card.
4. Remove cable 16 from the defrosting device and
attach it to connection 8 of terminal X1 (cable 12 is to
be removed from the terminal and from the defrosting
device).
5. Remove cable 103 from the defrosting device and
attach it to an active ground connection.
6. Connect the defrosting sensors to the display card
terminal G17-G18 (sensor 1) and G19-G20 (sensor 2)
and then in the evaporator. Use the clips that come
with the delivery to attach the sensors in the evaporator.
Position the sensors, depthwise, in the middle of the
evaporator. Attach the sensors 200 mm from the right
hand side (seen from the front) and 200mm from the
bottom edge and the upper edge respectively.
1. Start by transferring the cables from the old display card
to the new card. Start with connection G1 and then
transfer all cables of terminal G.
When all cables have been transferred, there will be four
spare connections at the top of the terminal (G17-G20).
2. In the same way, transfer the cables of terminal F from the
old display card to the new card.
Start with connection F1 and then transfer the other
cables. Connections F9 and F5 will then be empty.
3. Remove cable 16 from the defrosting device and attach it
to connection F9 on the display card.
4. Remove cable 11 (which is attached at connection A2 on
the soft-start card) from connection 7 of terminal X1 and
attach it to connection F2 on the display card. Remove
cable14.
5. Remove cable 105 from the defrosting device and attach
it to connection 6 of terminal X1 (cable 104 is removed
from terminal X1 and from the defrosting device).
6. Remove cable 103 from the defrosting device and attach
it to an active ground connection.
7. Connect the defrosting sensors to the display card
terminal G17-G18 (sensor 1) and G19-G20 (sensor 2) and
then in the evaporator. Use the clips that come with the
delivery to attach the sensors in the evaporator. Position
the sensors, depthwise, in the middle of the evaporator.
Attach the sensors 200 mm from the right hand side
(seen from the front) and 200mm from the bottom edge
and the upper edge respectively.