Read carefully the instruction manual. If the instrument is used in a manner
not specified by the producer, the protection provided by the instrument may
be impaired. Maintenance: make sure that the connections are correctly
carried out in order to avoid any malfunctioning or damage to the instrument.
PRODUCT DESCRIPTION
[1] Join or divide the modules ONLY when they are NOT power supplied
CONNECTION
Default IP address setting: DHCP; secondary IP address: 192.168.253.254. User ID:
admin; Default password: admin.
Note: it is possible to access the system with a PC to UWP3.0 connection by means of
a USB/mini-USB cable by following this procedure: (a) download the UWP3.0 Tool from
http://www.productselection.net ; (b) install the driver "linux.inf" from the folder “mini-USB
driver” included into the downloaded software package; (c) connect a USB/mini-USB ca-
ble from PC to UWP3.0; (d) access the UWP3.0 using the IP address: 192.168.254.254.
Part Description
A Ethernet port
B USB port (host function)
C
Indication LEDs:
Green
(ON)
ON
OFF
Power ON
Power OFF
Yellow
(BUS)
ON
OFF
Flashing
Communication OK on the HS-bus
No communicaton is present on the HS-bus
Communication error on the HS-bus
Yellow
(Port1)
OFF
Flashing 200 ms
ON, 600 ms OFF
Flashing 200 ms
ON, 200 ms OFF
No answer from the slave
No communications on RS485 COM1
Communications OK
Yellow
(Port2)
OFF
Flashing 200 ms
ON, 600 ms OFF
Flashing 200 ms
ON, 200 ms OFF
No answer from the slave
No communications on RS485 COM2
Communications OK
Blue
(USB)
ON
OFF
USB device is present
No USB device is present
Red
(Prg)
ON
OFF
Flashing
No conguration is present
Conguration present in the UWP
UWP is connected to the UWP 3.0 Tool
D Micro SD memory card slot
E Mini-USB port (Device function)
F RS485 COM1 port terminals
G RS485 COM2 port terminals
H Power supply connection block
I Local bus port (left side and right side)
FRANÇAIS
Lire attentivement le manuel de l’utilisateur. Si l’appareil est utilisé dans
des conditions différentes de celles spécifiées par le fabricant, le niveau de
protection prévu par l’instrument peut être compromis. Entretien: s’assurer que
les connexions sont réalisées correctement dans le but d’éviter toutes fautes ou
endommagements de l’appareil.
DESCRIPTION DU PRODUIT
[1] assembler ou dissocier les modules UNIQUEMENT s’ils ne sont pas alimentés
CONNEXION
Adresse IP par défaut: DHCP; adresse IP secondaire: 192.168.253.254. ID Utilisateur: admin;
Mot de passe par défaut: admin.
Remarque: il est possible d’accéder au système avec une connexion du PC à UWP 3.0 au
moyen d’un câble USB/mini-USB en suivant cette procédure: (a) télécharger l'outil UWP 3.0 de-
puis http://www.productselection.net ; (b) installer le driver "linux.inf" depuis le dossier "mini-USB
driver" inclus dans le paquet de download du logiciel; (c) connecter le câble USB/mini-USB du
PC à UWP 3.0; (d) accéder à UWP 3.0 en utilisant l’adresse IP: 192.168.254.254
ESPAÑOL
Lea atentamente este manual de instrucciones. Si el equipo se utiliza de
forma no especificada por el fabricante, la protección dotada al equipo puede
resultar dañada. Mantenimiento: Asegúrese de que las conexiones relevantes
se han llevado a cabo correctamente, con el fin de evitar un funcionamiento
incorrecto o que el equipo resulte dañado.
DESCRIPCIÓN DEL PRODUCTO
[1] unir o separar los módulos SÓLO cuando NO están alimentados
CONEXIÓN
Dirección IP predeterminada: DHCP; dirección IP secundaria: 192.168.253.254. ID usua-
rio: admin; Contraseña predeterminada: admin.
Nota: es posible acceder al sistema desde un PC conectado al módulo UWP 3.0 mediante
el cable USB/mini-USB siguiendo estos pasos: (a) descargar el tool UWP 3.0 desde http://
www.productselection.net ; (b) instalar el driver "linux.inf" desde la carpeta "mini-USB
driver" incluida en el paquete de descarga del software; (c) conectar un cable USB/
mini-USB desde el PC al módulo UWP 3.0; (d) acceder a UWP 3.0 usando la dirección IP:
192.168.254.254.
ITALIANO
Leggere attentamente il manuale di istruzioni. Qualora l’apparecchio venisse
usato in un modo non specificato dal costruttore, la protezione prevista
dall’apparecchio potrebbe essere compromessa. Manutenzione: Assicurarsi
che le connessioni previste siano eseguite correttamente al fine di evitare
qualsiasi malfunzionamento o danneggiamento dello strumento.
DESCRIZIONE DEL PRODOTTO
[1] unire o separare i vari moduli SOLO quando questi NON sono alimentati
CONNESSIONE
Indirizzo IP di default: DHCP; indirizzo IP secondario: 192.168.253.254. ID utente: admin;
Password di default: admin.
Note: è possibile accedere al sistema dal PC all'UWP 3.0 mediante una connessione
mini-USB ed il relativo cavo, seguendo la procedura: (a) scaricare il Tool UWP 3.0 da http://
www.productselection.net ; (b) installare il driver "linux.inf" dalla cartella "mini-USB driver"
incluso nel pacchetto di download del software; (c) connettere il cavo alla mini porta USB
dal PC all'UWP 3.0; (d) accedere all'UWP 3.0 utilizzando l’indirizzo IP 192.168.254.254.
Partie Description
A Port Ethernet
B Port USB (fonction hôte)
C
LED d’informations:
Verte
(ON)
ON
OFF
Alimentation ON
Alimentation OFF
Jaune
(BUS)
ON
OFF
Clignotante
Communication en course avec HS-bus
Pas de communication sur le HS-bus
Erreur de communication sur le HS-bus
Jaune
(Port1)
OFF
Clignot. 200ms
ON, 600ms OFF
Clignot. 200ms
ON, 200ms OFF
Pas de réponse de l'esclave
Pas de communication sur RS485 COM1
Communication normale
Jaune
(Port2)
OFF
Clignot. 200ms
ON, 600ms OFF
Clignot. 200ms
ON, 200ms OFF
Pas de réponse de l'esclave
Pas de communication sur RS485 COM2
Communication normale
Bleu
(USB)
ON
OFF
Dispositif reconnu
Aucun dispositif USB
Rouge
(Prg)
ON
OFF
Clignotante
Pas de communication
Communication en course sur UWP
UWP est connecté à UWP 3.0 Tool
D Logement carte mémoire Micro SD
E Port mini-USB (Fonction dispositif)
F Bornes port RS485 COM1
G Bornes port RS485 COM2
H Bornes d’alimentation
I Port bus local (côté gauche et côté droit)
Parte
Descripción
A Puerto USB
B Puerto USB (función host)
C
LED de indicación:
Verde
(ON)
ON
OFF
Alimentación conectada
Alimentación no conectada
Amarillo
(BUS)
ON
OFF
Parpadeando
Comunicación OK en el HS-bus
No hay comunicación en el HS-bus
Error de comunicación en el HS-bus
Amarillo
(Port1)
OFF
Parpad. 200 ms
ON, 600 ms OFF
Parpad. 200 ms
ON, 200 msOFF
Sin respuesta del esclavo
Sin comunicación en RS485 COM1
Comunicación regular
Amarillo
(Port2)
OFF
Parpad. 200 ms
ON, 600 ms OFF
Parpad. 200 ms
ON, 200 ms OFF
Sin respuesta del esclavo
Sin comunicación en RS485 COM2
Comunicación regular
Azul
(USB)
ON
OFF
Dispositivo USB reconocido
No hay dispositivo USB
Rojo
(Prg)
ON
OFF
Parpadeando
Sin conguración
Hay conguración en UWP
UWP está conectado a UWP 3.0 Tool
D Ranura para tarjeta de memoria micro SD
E Puerto mini USB (función de dispositivo)
F Terminales de puerto RS485 COM1
G Terminales de puerto RS485 COM2
H Bloque de conexión de la alimentación
I Puerto del bus local (lado izquierdo y lado derecho)
Parte Descrizione
A Porta Ethernet
B Porta USB (funzione host)
C
Indicatori a LED:
Verde
(ON)
ON
OFF
Alimentazione ON
Alimentazione OFF
Giallo
(BUS)
ON
OFF
Lampeggiante
Corretta comunicazione su HS-bus
Nessuna comunicaz. presente su HS-bus
Errore di comunicazione su HS-bus
Giallo
(Port1)
OFF
Lamp. 200 ms
ON, 600 ms OFF
Lamp.
200 ms
ON, 200 msOFF
Nessuna risposta dallo slave
Nessuna comunicazione su RS485 COM1
Comunicazione corretta
Giallo
(Port2)
OFF
Lamp. 200 ms
ON, 600 ms OFF
Lamp.
200 ms
ON, 200 msOFF
Nessuna risposta dallo slave
Nessuna comunicazione su RS485 COM2
Comunicazione corretta
Blu
(USB)
ON
OFF
Il dispositivo USB è presente
Nessun dispositivo USB è presente
Rosso
(Prg)
ON
OFF
Lampeggiante
Nessuna congurazione presente
Congurazione presente nel UWP
UWP è collegato al software UWP 3.0 Tool
D Slot per scheda di memoria Micro SD
E Porta Mini-USB (Funzione dispositivo)
F Terminali porta COM1 RS485
G Terminali porta COM2 RS485
H Morsetti di alimentazione
I Porta bus locale (lato sinistro e lato destro)
Approvals: CE, cULus according to UL60950.
UL notes:
This product is intended to be supplied by a Listed Information Technology
Equipment AC Adaptor marked NEC Class 2 or LPS.
Max ambient temperature: 40°C
Homologations: CE, cULus selon UL60950.
Notes UL:
Ce produit est conçu pour être alimenté par un adaptateur secteur Listés
comme équipements de technologie de l'information NEC Classe 2 ou LPS.
Température ambiante maxi: 40°C
1. 2.
12 - 28
VDC
5W@40°C
< 1.5 mm
2
3.
4. 5.
6.
[1]
7.
90.0
44.0 14.5
45.0
5.0
36.0

Modbus
Device 1
Modbus
Device n
COM1
COM2
T
MAINTENANCE AND DISPOSAL
Responsibility for disposal
The product must be disposed of at the relative recycling centers specied by the
government or local public authorities. Correct disposal and recycling will contribute to
the prevention of potentially harmful consequences to the environment and persons.
CAUTION! Toxic substances. Environmental pollution and hazard. Intoxication.
Dispose of the battery together with the device. The embedded metal-ion battery of this product
must be removed exclusively by specialized personnel to be correctly disposed of.
ENTRETIEN ET ÉLIMINATION
Responsabilité en matière d’élimination
Éliminer selon le tri sélectif avec les structures de récupération indiquées par l’État ou
par les organismes publics locaux. Bien éliminer et recycler aidera à prévenir des
conséquences potentiellement néfastes pour l’environnement et les personnes.
ATTENTION ! Substances toxiques. Pollution et dommages à l’environnement.
Intoxication. Éliminer la batterie en même temps que le dispositif. La batterie lithium-métal de ce
produit doit être enlevée exclusivement par personnel spécialisé pour l'éliminer.
MANTENIMIENTO Y ELIMINACIÓN
Responsabilidad de eliminación
Eliminar mediante recogida selectiva a través de las estructuras de recogida indicadas
por el gobierno o por los entes públicos locales. La correcta eliminación y el reciclaje
ayudarán a prevenir consecuencias potencialmente negativas para el medioambiente
y para las personas. ¡ATENCIÓN! Sustancias tóxicas. Contaminación y daños
medioambientales. Intoxicación. Eliminar la batería junto al dispositivo. La batería de litio-metal
de este producto debe ser retirada solo por personal calicado para luego eliminarla.
MANUTENZIONE E SMALTIMENTO
Responsabilità di smaltimento
Smaltire con raccolta dierenziata tramite le strutture di raccolte indicate dal governo o
dagli enti pubblici locali. Il corretto smaltimento e il riciclaggio aiuteranno a prevenire
conseguenze potenzialmente negative per l’ambiente e per le persone. ATTENZIONE!
Sostanze tossiche. Inquinamento e danni all’ambiente. Intossicazione. Smaltire la
batteria unitamente al dispositivo. La batteria integrata al litio metallico di questo prodotto deve
essere rimossa esclusivamente da personale specializzato, per poi essere smaltita
correttamente.
Security
Capabilities
Verified
SILVER
V
1 3 7 2 6 0
IoT Security Rating:
Security Capabilities Veried to Level SILVER








IP20
IP40
-20°C to +50°C
(-4°F to 122°F)
-30°C to +70°C
(-22°F to 158°F)
DEUTSCH
Die Betriebsanleitung aufmerksam lesen. Sollte das Gerät nicht gemäss der
Herstellerangaben verwendet werden, könnte der vom Gerät vorgesehene Schutz
beeinträchtigt werden. Wartung: Sicherstellen, Anschlüsse richtig ausgeführt
wurden, um schlechte Funktion oder Beschädigung des Gerätes zu vermeiden.
PRODUKTBESCHREIBUNG
[1] Die Modules dürfen nur voneinander getrennt oder aneinandergereiht werden, wenn diese
nicht an die Spannungsversorgung angeschlossen sind
ANSCHLUSS
Default IPAdresse: DHCP; sekundäre IPAdresse: 192.168.253.254. Benutzter-ID: admin;Standard-
Passwort: admin.
Hinweis: auf das System kann mit einem PC über den Anschluss UWP 3.0 mittels eines USB-/
Mini-USB-Kabels entsprechend diesem Vorgang zugegriffen werden: (a) das UWP3.0 Tool von
http://www.productselection.net herunterladen; (b) den Treiber "linux.inf " aus dem Ordner "Mini-
USB-Treiber" installieren, der im heruntergeladenen Softwarepaket enthalten ist; (c) Schließen Sie in
USB-/Mini-USB-Kabel vom PC an den UWP 3.0 an; (d) Greifen Sie auf den UWP 3.0 mittels der
IP-Adresse: 192.168.254.254 zu.
DANSK
Læs brugervejledningen omhyggeligt. Hvis instrumentet
skal anvendes på en måde, der ikke er beskrevet af
producenten, kan beskyttelsen af instrumentet blive svækket.
Vedligeholdelse: Kontrollér, at tilslutningerne er foretaget korrekt
for at undgå fejlfunktioner eller beskadigelse af instrumentet.
PRODUKTBESKRIVELSE
[1] Modulerne må kun afbrydes eller tilsluttes når strømforsyningen er afbrudt
FORBINDELSE
Standard IP-adresse: DHCP; sekundær IP-adresse:192.168.253.254. Bruger-id: admin;
Standardadgangskode: admin.
Bemærk: Det er muligt at få adgang til systemet med en pc-til-UWP 3.0-forbindelse ved
hjælp af et USB-/mini-USB-kabel ved at gøre følgende: (a) downloade værktøjet UWP 3.0
fra http://www.productselection.net; (b) installere driveren "Linux. inf " fra mappen "mini-USB
driver" inkluderet i den downloadede softwarepakke; (c) slut et USB-/mini-USB-kabel fra pc til
WP 3.0; (d) få adgang til UWP 3.0’en ved hjælp af IP-adressen: 192.168.254.254.
SVENSKA
Läs noggrant genom manualen. Om instrumentet används på ett
sådant vis som inte specificeras av tillverkaren, kan instrumentets
angivna säkerhet reduceras. Underhåll: försäkra att alla anslutningar är
korrekt anslutna för att undvika funktionsfel eller skada på instrumentet.
PRODUKTBESKRIVNING
[1] Modulerna får endast kopplas isär eller ihop när manöverspänningen är bruten
ANSLUTNING
Inställning av standard-IP-adress: DHCP; sekundära IP-adressen: 192.168.253.254.
Användar-ID: admin; Standardlösenord: admin.
Obs: det är möjligt att komma åt systemet med en PC till UWP 3.0 anslutning med
hjälp av en USB/Mini-USB-kabel genom att följa denna procedur: (a) Ladda ner UWP
3.0 Tool från http://www.productselection.net; (b) installera driv rutinen "Linux. inf "
från mappen "mini-USB-drivrutin" som ingår i den nedladdade mjukvaru paketet; (c)
Anslut en USB/Mini-USB-kabel från PC till UWP 3.0; (d) till gång till UWP 3.0 med
hjälp av IP-adressen: 192.168.254.254.
NORSK
Les nøye bruksanvisningen. Hvis produktet er brukt på en måte
som ikke er angitt av produsenten, kan beskyttelsen av
produktet bli svekket. Vedlikehold: sørge for at tilkoblingene er
korrekt utført for å unngå funksjonsfeil eller skade på produktet.
PRODUKTBESKRIVELSE
[1] Modulene kan bare kobles fra eller koblet til når strømforsyningen er avbrutt
TILKOBLING
Innstilling for standard IP-adresse: DHCP; sekundær IP-adresse: 192.168.253.254. Bruker-
ID: admin; Standard passord: admin.
Merk: det er mulig å få tilgang til systemet med en PC til UWP 3.0-tilkobling ved hjelp av en
USB/Mini-USB-kabel ved å følge denne fremgangsmåten: (a) laste ned UWP 3.0-verktøyet
fra http://www.productselection.net; (b) installere driveren "Linux. inf " fra mappen "mini-USB
driver" inkludert i den nedlastede programvarepakken; (c) koble en USB/Mini-USB-kabel fra
PC til UWP 3.0; (d) få tilgang til UWP 3.0 ved hjelp av IP-adressen: 192.168.254.254.
UWP30RSEXXXSE
Instruction Manual
MANUAL UWP30RSEXXXSE code 8022108 / 120321 http://www.carlogavazzi.com/ CARLO GAVAZZI
Teil Beschreibung
A Ethernet-Port
B USB-Port (Host-Funktion)
C
Informations-LED:
Grüne
(ON)
EIN
AUS
Betriebsspannung EIN
Betriebsspannung AUS
Gelbe
(BUS)
EIN
AUS
Blinkt
Kommunik. an den HS-bus wird durchgeführt
Keine Kommunikation an den HS-bus
Kommunikationsfehler an den HS-bus
Gelbe
(Port1)
AUS
Blinkt 200 ms
EIN, 600 ms AUS
Blinkt 200 ms
EIN, 200 ms AUS
Keine Antwort vom Slave
Keine Kommunikation an den RS485 COM1
Reguläre Kommunikation
Gelbe
(Port2)
AUS
Blinkt 200 ms
EIN, 600 ms AUS
Blinkt 200 ms
EIN, 200 ms AUS
Keine Antwort vom Slave
Keine Kommunikation an den RS485 COM2
Reguläre Kommunikation
Blau
(USB)
EIN
AUS
Bestätigtes USB-Gerät
Kein USB-Gerät
Röte
(Prg)
EIN
AUS
Blinkt
Keine Konguration
Konguration an den UWP
UWP ist an den SB(H)Tool angeschlossen
D MicroSD-Speicherkartensteckplatz
E Mini-USB-Port (Gerätefunktion)
F RS485 COM1-Port-Klemmen
G RS485 COM2-Port-Klemmen
H Stromanschluss
I Lokaler Bus-Port (linke und rechte Seite)
Del Beskrivelse
A Ethernet-port
B USB-port (værtsfunktion)
C
Informationsdiode:
Grøn
(ON)
ON
OFF
Forsyning ON
Forsyning OFF
Gul
(BUS)
ON
OFF
Blinker
Kommunikation OK på HS-bus
Der er ingen kommunikation på HS-bus
Kommunikationsfejl på HS-bus
Gul
(Port1)
OFF
Blinker 200 ms
ON, 600 ms OFF
Blinker 200 ms
ON, 200 ms OFF
Intet svar fra slave
Ingen kommunikation på RS485 COM1
Kommunikation OK
Gul
(Port2)
OFF
Blinker 200 ms
ON, 600 ms OFF
Blinker 200 ms
ON, 200 ms OFF
Intet svar fra slave
Ingen kommunikation på RS485 COM2
Kommunikation OK
Blå
(USB)
ON
OFF
Anerkendelse USB-enhed
Ingen USB-enhed
Rød
(Prg)
ON
OFF
Blinker
Ingen konguration stede
Kongurationen til stede i UWP.
UWP er forbundet til UWP 3.0-værktøjet
D Åbning til mikro SD-hukommelseskort
E Mini-USB port (enhedsfunktion)
F RS485 COM1-portterminaler
G RS485 COM2-portterminaler
H Strømterminaler
I Lokal busport (venstre og højre side)
Del Beskrivning
A Ethernet-port
B USB-port
C
LED-indikerin:
Grön
(ON)
AV
Ström PÅ.
Ström AV
Gul
(BUS)
AV
Blinkar
Kommunikation OK på HS-bus
Ingen kommunikation nns på HS-bus
Kommunikationsfel på HS-bus
Gul
(Port1)
AV
Blinkar 200 ms
PÅ, 600 ms AV
Blinkar 200 ms
PÅ, 200 ms AV
Inget svar från slaven
Ingen kommunikation på RS485 COM1
Kommunikation OK
Gul
(Port2)
OFF
Blinkar 200 ms
PÅ, 600 ms AV
Blinkar 200 ms
PÅ, 200 ms AV
Inget svar från slaven
Ingen kommunikation på RS485 COM2
Kommunikation OK
Blå
(USB)
AV
Erkänt USB-enhet
Ingen USB-enhet
Röd
(Prg)
AV
Blinkar
Ingen kongurering nns
Konguration nns i UWP
UWP är ansluten till UWP 3.0-verktyget
D Micro SD
E Mini-USB port
F RS485 COM1
G RS485 COM2
H Manöverspänning
I Lokalbuss
Del Beskrivelse
A Ethernet-port
B USB-port (Host-funksjon)
C
LED-indikering:
Grønn
(ON)
AV
Tilførsel PÅ
Tilførsel AV
Gule
(BUS)
AV
Blinker
Kommunikasjon OK HS-bus
Ingen kommunikasjon er til stede på HS-bus
Kommunikasjonsfeil på HS-bus
Gule
(Port1)
AV
Blinker 200 ms
PÅ, 600 ms AV
Blinker 200 ms
PÅ, 200 ms AV
Ikke noe svar fra slave
Ingen kommunikasjon på RS485 COM1
Kommunikasjon OK
Gule
(Port2)
OFF
Blinker 200 ms
PÅ, 600 ms AV
Blinker 200 ms
PÅ, 200 ms AV
Ikke noe svar fra slave
Ingen kommunikasjon på RS485 COM2
Kommunikasjon OK
Blå
(USB)
AV
Anerkjent USB-enhet
Ingen USB-enhet
Rød
(Prg)
AV
Blinker
Ingen kongurasjon stede
Kongurasjon stede i UWP
UWP er koblet til UWP 3.0 Tool
D Micro SD-minnekortspor
E Mini USB-port (Enhetsfunksjon)
F RS485 COM1-port terminals
G RS485 COM2-port terminals
H Klemme til forsyning
I Lokalbuss port (venstre side og høyre side)
1. 2.
12 - 28
VDC
5W@40°C
< 1.5 mm
2
3.
4. 5.
6.
[1]
7.
90.0
44.0 14.5
45.0
5.0
36.0

Modbus
Device 1
Modbus
Device n
COM1
COM2
T
WARTUNG UND ENTSORGUNG
Verantwortlichkeit für die Entsorgung
Es muss für getrennte Abfallentsorgung anhand der von der Regierung oder den
öentliche Lokalbehörden benannten Sammelstrukturen gesorgt werden. Die
korrekte Entsorgung bzw. das Recycling tragen dazu bei, potentiell negative
Auswirkungen auf die Umwelt und die Personen zu vermeiden. ACHTUNG!
Giftstoe. Umweltverschmutzung und Gefahr. Vergiftung. Den Akku zusammen mit dem
Gerät entsorgen. Der in dieses Produkt eingebaute Metallionen-Akku darf nur durch
Fachpersonal entfernt werden, sonst ist keine ordnungsgemäße Entsorgung gewährleistet.
HÅNDTERING OG BORTSKAFFELSE
Ansvar vedrørende bortskaelse
Sorteres og bortskaes på genbrugsplads, som angivet af stat eller
kommune. Den korrekte bortskaelse og genbrug er med til at forhindre
potentielt negative følger for miljøet og personer. ADVARSEL! Giftige
substanser. Miljøforurening og -fare. Forgiftning. Bortskaf batteriet sammen
med enheden. Det indbyggede metal-ion batteri i dette produkt må kun fjernes af
specialuddannet for at sikre korrekt bortskaelse.
SKÖTSEL OCH UNDERHÅLL
Avfallshantering
Denna symbol innebär att produkten inte får kastas tillsammans med annat
hushållsavfall. För att förebygga eventuell skada på miljö och hälsa orsakad
av felaktig avfallshantering, ska produkten lämnas till återvinning. Använd dig
av de returhanteringssystem som finns där du befinner dig eller kontakta
inköpsstället.
Avfallshåndtering:
Produktet skal leveres inn til en godkjent gjenvinningsstasjon eller mottaker av
EE-avfall. Riktig håndtering og resirkulering vil bidra til å forebygge potensielt
skadelige konsekvenser for mennesker og miljø. ADVARSEL! Giftige stoffer.
Miljøforurensning og fare. Rus. Kast batteriet sammen med enheten. Det
innebygde metall-ion-batteriet til dette produktet må fjernes utelukkende av spesiali-
sert personell for å avhendes korrekt.
Security
Capabilities
Verified
SILVER
V 1 3 7 2 6 0
IoT Security Rating:
Security Capabilities Veried to Level SILVER








IP20
IP40
-20°C to +50°C
(-4°F to 122°F)
-30°C to +70°C
(-22°F to 158°F)
  • Page 1 1
  • Page 2 2

CARLO GAVAZZI UWP30RSEXXXSE Installationsguide

Typ
Installationsguide