FM Mattsson Wall Plate 160 c/c Bruksanvisningar

Typ
Bruksanvisningar
160 c/c Blandarfäste för lödfria anslutningar
160 c/c Wall plate for solder free connections
Drift- och monteringssanvisning • Drifts- og installasjonsanvisning • Drifts- og monterings-vejledning
Asennus- ja huolto-ohje • Installation and maintenance instruction • Betriebs- und Installationsanleitung
Installatie- en onderhoudsgids • Installation et notice de montage
Teknisk information ................................ 2
Montering............................................... 3
Demontering .......................................... 6
Rengöring .............................................. 6
Technical information ............................. 2
Installation ............................................. 3
Dismantling ............................................ 6
Cleaning ................................................ 6
Innehåll Contents
Accepterad
monteringsanvisning
2021:1
C9000263
2 (8)
Artikelnr./
Item no.
Rördimension ØD/
Pipe dimension ØD
S600031 Ø12
S600032 Ø15
SVENSKA
Teknisk data
Används för tappvatten.
Driftstryck: 50-1000 kPa. (Rekommenderat värde 100-500 kPa).
Max provningstryck: 1600 kPa.
Max varmvattentemperatur: 80°C. (Rekommenderat värde 60°C).
Passar 160 c/c blandare med inloppskopplingar M26x1,5 enligt standard SMS 3269 och SS 1028.
Kopplingarna är avsedda för kopparrör enligt standard SS-EN 1057.
Stödhylsa ska användas på mjuka (R220) och halvhårda (R250) rör.
Täthetskontroll
Tryck- och täthetskontroll ska utföras enligt anvisningar på säkervatten.se.
Det går att provtrycka innan man monterar med hjälp av speciella provtryckningspluggar,
FMM 1715-2609 (RSK 853 16 91).
Skador som orsakas till följd av spänningskorrosion som uppstår på grund av vattnets eller den
omgivande miljöns beskaenhet samt felaktig montering inkluderas inte i produktansvaret.
D
100
M26x1,5
50
210
160
27±1
6-9
3 (8)
1
2
3
4
5
6
7
8
9
10
11
12
2
Montering
Installationen ska utföras enligt branschregler Säker Vatteninstallation. Vi rekommenderar att du anlitar
ett auktoriserat VVS-företag.
OBS! Vid ny rörinstallation måste rören renspolas innan blandaren monteras.
Rören ska vara xerade och monterade vinkelräta mot vägg på ett centrumavstånd av 160±1 mm.
1. Plasthöljet på rören kapas 6-9 mm utanför färdig vägg eller enligt rörleverantörens monteringsanvisning.
2. Markera på kopparrören 27±1 mm ifrån väggen.
3. Kapa kopparrören vid markeringen.
4. Putsa av alla invändiga och utvändiga grader på rören efter kapning.
90°
160±1
1
4
3
Silicone
Silicone
A
B
C
D
E
Silicone
A
B
C
4 (8)
Fig. 1
Fig. 2
100
5
5. Skruvinfästningar i plats för bad eller dusch ska
göras i betong eller annan massiv konstruktion,
träreglar, träkortlingar eller i konstruktion som är
provad och godkänd för infästning.
Alla infästningar med skruv genom tätskikt ska
tätas, se ”Fig. 1” eller ”Fig. 2”. Material för tätning
ska fästa mot underlaget och vara vattenbestän-
digt, mögelresistent och åldersbeständigt.
5 (8)
6. Montera blandarfästet på rören, med dräneringshålet nedåt. Skruva därefter fast blandarfästet i
väggen. Muttrarna är försedda med två o-ringar som ska förhindra att vatten tränger in i
väggen. Den ena tätar mot röret och den andra mot väggbrickan.
6
Dräneringshål
7. Vid mjuka eller halvhårda rör, montera stödhylsor i rören och trä på konorna.
8. Montera sedan blandaren. Drag åt för hand så långt som möjligt, därefter enligt bifogad tabell
moment/varv. Dra muttrarna växelvis. Smörj gänga och klämring med Locher pasta special för
att underlätta åtdragning. Se även ”Tekniska data” i FM Mattssons katalog.
OBS! Vid åtdragning av muttrarna, var försiktig så att ytan på blandarfästet inte skadas.
Skyddstejp som bifogas blandarna skall användas vid montering/demontering
avseende färgade blandare.
9. Montera koppling och blandare enligt instruktion FMM 1003549.
10. Efter åtdragning. Motverka spänningskorrosion samt kontrollera att konan har dragit genom att
lossa mutter och drag åt lätt igen. Provtryck och kontrollera, efterdrag vid behov.
7
8
6 (8)
Demontering
1. Demontera blandaren.
2. Demontera konorna från rören
med hjälp av konavdragare FMM
6097-0000 (RSK 859 28 35).
3. Skruva ut konavdragarens skruv [a]
till ytterläge. Om adaptern [b] skall
användas stoppas den in i kon-
avdragaren, vänd den rätt så den
passar röret.
4. Skjut på konavdragaren [c] över
konan, skjut in den så långt att den
greppar över konan.
5. Trä på styrhylsan [d] och skruva i den
i muttern.
6. Dra av konan genom att skruva in
kon avdragarens skruv. När skruven
dragits mot stopp är konan lös och
konavdragaren dras ut ur styrhylsan
(skruven dras mot ett stopp när
adaptern används).
7. Peta ur konan ur konavdragaren och
skruva ur styrhylsan.
8. När båda konorna dragits av kan
blandarfästet demonteras från väggen.
Återmontering, se ”Montering”.
FMM 6097-0000
1
2
[a]
[c]
[b]
[d]
8
Rengöring
Torka av din produkt ofta för att bevara dess livslängd. Använd en mikroberduk. Vid behov, fukta
trasan eller använd en mild tvållösning som direkt sköljs bort och torka ytan torr.
OBS! Använd INTE rengöringssvampar med grov yta, rengöringsmedel som innehåller syror, kalk-
lösningsmedel eller ättikssprit för att rengöra produkten. Innehållet i dessa medel kan förstöra ytan
på din produkt. Materialskador på produktens yta som orsakats av felaktig rengöringsmetod
kommer inte ersättas av vår garanti.
För produkt som inte har kromad yta, se skötselråd för respektive produkt på vår hemsida.
7 (8)
ENGLISH
Technical data
Used for tap water.
Operating pressure: 50–1000 kPa. (Recommended value 100–500 kPa).
Max test pressure: 1600 kPa.
Max. hot water temperature: 80°C. (Recommended value 60°C).
Fits 160 mm c/c mixers with inlet connectors M26x1.5 compliant with standards SMS 3269 and SS 1028.
The couplings are intended for copper pipes according to standard SS-EN 1057.
A supporting bush should be used on soft (R220) and semi-hard (R250) pipes.
Tightness check
Pressure and tightness tests must be performed as instructed at säkervatten.se.
You can perform a pressure test before installation using special pressure testing plugs FMM 1715-2609 (RSK 853 16 91).
Product liability does not cover damage resulting from stress corrosion caused by characteristics of the water or surrounding
environment.
Installation
The installation should be performed according to safe water installation industry regulations. Installation should be carried out by an
authorised water and sanitation company.
NOTE: When installing new pipes, the pipes must be ushed clean before the mixer is connected.
The pipes should be xed and installed at right angles to the wall, with a centre distance of 160±1 mm.
1. Cut the plastic sleeve so that 6–9 mm protrudes outside the nished wall, or according to the pipe supplier’s installation instructions
2. Mark the copper pipes at a distance of 27±1 mm from the wall.
3. Cut the copper pipes at the marking
4. File off all sharp edges from the inside and outside of the pipes after cutting them.
5. The screw mountings where the bath or shower will be installed should be of a sturdy design, for instance made of concrete,
wooden studs, wooden nogging pieces or a design that has been tested and approved for mounting. If mountings are tted with
screws through the moisture barrier, the holes must be sealed. See “Fig. 1” or “Fig. 2”. The sealant material must attach rmly to the
underlying surface and be water-resistant, mould-resistant and non-ageing.
6. Fit the mixer bracket to the pipes with the drainage hole facing downwards. Then screw the mixer bracket to the wall. The nuts have two
O-rings designed to prevent water from penetrating into the wall. One of them seals against the pipe, and the other seals against the
wall plate.
7. If using soft or semi-hard pipes, install supporting bushes in the pipes and push the cones onto them. Then install the mixer. Tighten
by hand as far as possible, then according to the enclosed table (torque/rotation). Tighten the nuts alternately. Lubricate the thread
and clamp ring with Locher Pasta Special to facilitate tightening. Also see “Technical data” in the FM Mattsson catalogue.
NOTE: Take care not to damage the surface of the mixer bracket when tightening the nuts
Use the protective tape provided with the mixers when tting or dismantling coated mixers.
8. Fit the connector and mixer according to the instructions FMM 1003549
9. After tightening. To prevent stress corrosion and to check that the cone is tightened sufciently, loosen the nut and tighten it lightly
again. Perform a pressure test, check and tighten again as necessary.
Dismantling
1. Disconnect the mixer.
2. Dismantle the cones from the pipes using cone remover FMM 6097-0000 (RSK 859 28 35).
3. Unscrew the screw on the cone remover to its outermost position. If using the adapter [b], insert it into the cone remover. Turn it the
right way round so that it ts the pipe.
4. Press the cone remover [c] over the cone. Push it in until it grips over the cone.
5. Thread the guiding bush [d] into place and screw it into the nut.
6. Pull the cone off by turning the screw for the cone remover inwards. When the screw has been tightened to the stop point, the cone
will be loose. Now pull the cone remover out of the guiding bush (the screw is tightened to the stop point when the adapter is used).
7. Prise the cone out of the cone remover and unscrew the guiding bush.
8. When both the cones have been pulled off, the mixer bracket can be detached from the wall.
Reassembly, see “Installation”.
Cleaning
Wipe your product clean frequently to prolong its life. Use a microbre cloth. If necessary, dampen the cloth with water. Alternatively, use
a mild soap solution, rinse immediately and wipe the surface dry.
NOTE: Do NOT use abrasive sponges, acid cleaners, descalers or spirit vinegar to clean your product. The contents of these products
risk damaging the surface of your product. Our guarantee does not cover any damage to the product’s surface that is caused by
incorrect cleaning.
For products that do not have a chrome nish, see the specic care instructions for the product on our website.
Rev. 002 - 2021-03-23 FMM nr 100 79 94
FM Mattsson Mora Group AB
FM Mattsson
Box 480
SE-792 27 Mora
Tel. +46 (0)250 59 60 00
www.fmmattsson.se
FM Mattsson Mora Group AB
International
FM Mattsson
Box 480
SE-792 27 Mora
Tel. +46 (0)250 59 61 00
www.fmmattsson.com
FM Mattsson Mora Group
Norge AS
FM Mattsson
Strømsveien 200, 3. etasje
NO-0668 Oslo
Tel. +47 22 09 19 00
www.fmmattsson.no
FM Mattsson Mora Group
Danmark ApS
FM Mattsson
Hvidkærvej 48
DK-5250 Odense SV
Tel. +45 43 43 13 43
www.fmmattsson.dk
FM Mattsson Mora Group
Finland OY
FM Mattsson
Sahaajankatu 24
FI-00880 Helsinki
Tel. 020 7411 960
www.fmmattsson.fi
Mora GmbH
FM Mattsson
Biedenkamp 3c
DE-21509 Glinde bei Hamburg
Tel. +49 (0)40 53 57 08 - 0
www.fmmattsson.de
FM Mattsson Mora Group
FM Mattsson
Plesmanstraat 4
NL-3833 LA Leusden
Tel. +31 85 401 87 80
www.fmmattsson.nl
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

FM Mattsson Wall Plate 160 c/c Bruksanvisningar

Typ
Bruksanvisningar