Nilfisk HSC585 Bruksanvisning

Typ
Bruksanvisning

Denna manual är också lämplig för

-1-
11600205211REVA
INFORMATION
&
OPERATING
INSTRUCTIONS
10.22.2007
HSC 585 MULTI
EXTRACTOR
220 - 240V EU & UK
CAUTION: DO NOT OPERATE MACHINE
UNTIL YOU HAVE READ ALL SECTIONS
OF THIS INSTRUCTION MANUAL
26022008
WARNING!
To reduce the risk of fire, electric shock, or injury:
Do not leave the machine unattended when it is plugged-in. Unplug the unit from the power outlet
when not in use.
Unplug the machine from the power outlet before cleaning or servicing.
Turn off all controls before unplugging.
To avoid electric shock, do not expose to rain or snow. Store and use indoors.
Wear hearing protection if desired. The measured sound level of the HSC585 is 75 dB(A)
Do not allow to be used as a toy. Close attention is necessary when used near children.
Use only as described in this manual. Use only the manufacturer’s recommended attachments.
Inspect the power cord regularly for damage, such as cracking, ageing, or damaged insulation. Do
not use with damaged cord or plug. If the cord needs to be replaced, take the machine to an
authorized Nilfisk
If the cord or prongs become damaged have it replaced by an authorized Nilfisk service technician
or partner.
Use a defoamer any time you get foam in the recovery tank, to prevent motor damage.
If foam or liquid comes out of the vacuum motor or exhaust, turn the machine off immediately.
If the machine is not working as it should, has been dropped, damaged, left outdoors or flooded
with water, return it to a service center.
Do not pull the machine by the cord, do not use the cord as a handle, close a door on the cord, or
pull the cord around sharp edges or corners. Do not run the machine over the cord. Keep the cord
away from heated surfaces.To unplug, grasp the plug, not the cord.
Do not handle the plug, the cord, or the machine with wet hands.
Extension cords must be 12 GA and no longer than 15 meters. Replace the cord or unplug
immediately if the ground prong becomes damaged.
Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint,
hair, and anything that may reduce air flow.
Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes, or
any health endangering dusts. Do not use to pick up flammable or combustible liquids such as
gasoline or use in areas where they may be present.
Use extra care when cleaning on stairs.
Connect to a properly grounded outlet only.
Liquid pumped out could be dangerous because of temperature, pressure, or chemical content.
Do not let the pump run dry. If you run out of water, turn the machine off and refill.
IMPORTANT SAFETY INSTRUCTIONS
This machine is only suitable for commercial use, for example in hotels, schools, hospitals, factories,
shops, and offices other than normal residential housekeeping purposes.
When using any electrical appliance, basic precautions should always be followed, including the following:
NOTE: Read all instructions before using this machine.
-3-
11600205211REVA
INSPECTION:
Carefully unpack and inspect your Nilfisk HSC 585-MULTI for shipping damage. Each machine is
tested and inspected before shipping. Any shipping damage incurred is the responsibility of the
carrier. You should notify the carrier immediately if you notice damage to the box or to the
machine or parts.
CLEANING SOLUTIONS:
Select a proper pre-spray for the surface to be cleaned, and apply the pre-spray. Use a neutral
pH rinse or detergent (6 to 9 pH) in the Nilfisk HSC 585 to prevent premature wear of the pump,
seals and other components. Powdered chemicals are not recommended.
MAINTENANCE:
For optimum performance, flush the machine with clear water at the end of each working day.
Once a month, minimum, run a flushing compound through the machine to break up any
mineral or chemical build-up that may have formed in the lines, the pumps, or the heater.
The vacuum motor, pump motor, and the pump do not require any scheduled maintenance;
however, the vacuum motors may require replacement brushes after 1000 - 1500 hours, and the
high pressure pump and unloader valve may require rebuild kits after 500 -1000 hours (refer to
machine part list for numbers). Clean the body with an all purpose detergent, and protect it with
an automobile interior polish. Lubricate the wheels, castors, and quick disconnects with an all-
purpose silicone spray.
Record the serial number and model of your new extractor here:
Model:
Nilfisk HSC 585-Multi_ Serial Number: __________________
Purchase Date:
_____________
Write the name and phone number of your distributor:
_____________________________________
_____________________________________
NOTE: to remove the complete reel with hoses from the machine, pull the vacuum hose loose
from the hose barb on the front of the tank, and push the short piece of vacuum hose into the
center of the hose spool. Disconnect the solution hose quick coupling. Grasp the spool from either
side, and lift it off the machine.
NOTE: before servicing any component in the base cabinet, remove the hoses and spool before
opening the tanks.
O
I
I
I
O
O
I
I
SWITCH PLATE
5
HIGH
PRESSURE
PUMP
LIGHT
(NO HEAT)
DUMP PUMP
ON/OFF
SWITCH
PUMP/HEAT
SELECTOR
SWITCH
100 PSI
PUMP
ON/OFF
SWITCH
3
VACUUM
ON/OFF
SWITCH
2
4
HEAT
SELECTED
LIGHT
KNOW YOUR MACHINE
Nilfisk HSC 585 MULTI
Switches
85 Bar
Quick
Disconnect
Hoses
Vacuum Hose
Connection
Base
Compartment
Vac Tank
Latch
7 Bar
Quick Disconnect
Solution
Tank
Wheel
Drain Hose
Cap
Wand Holder
Vacumm
Tank Lid
Castor
with Brake
Pressure
Gauge
Wheel
Power
Prime
Pedal
Garden Hose
Connector
Drain Hose
Auto
Dump
Pump
Power
Cord
OPERATION
REFER TO THE DIAGRAMS ON THE PREVIOUS PAGE
HIGH PRESSURE WASHER
1 Before each use, inspect the machine, hoses, and cleaning tools for cleanliness and completeness. Make
sure hoses are in good condition and the spray nozzle(s) is tight.
REFER TO THE AUTO-FILL AND AUTO-DUMP INSTRUCTIONS ON THE FOLLOWING PAGES.
2. If you choose to use the automatic pump-out feature, connect the dump hose to the brass hose fitting
on the back of the machine, and place the open end of the hose in a drain. Make sure the drain hose
on the back of the vacuum tank is closed, and the lid is tight on the recovery tank. NOTE: never turn
ON the automatic pump-out switch unless you have removed the brass cap from the hose connector on
the rear of the machine. This pump will run continuously if it is turned on, and if the water can not be
pumped out (cap still screwed on) damage may occur to the pump.
If you choose not to use the auto pump-out option, just make sure the brass cap is on the hose
connector on the rear of the machine. CAUTION: do not turn the pump-out switch on if the cap is still
on the hose connector on the back of the machine.
3. If you choose to use the auto-fill feature, connect the fill-hose to the auto-fill valve (located over the
solution tank fill hole). Turn on the water source. NOTE: do not turn the water on full power. The water
flowing into the auto-fill system does not need a lot of pressure behind it. Allow the tank to fill with
solution. When you use the auto-fill system, the auto-fill valve will automatically turn on and turn off as
the tank empties and then fills. NOTE: If you are not going to use the auto-fill system, just fill the
tank with water and cleaning chemical. Follow chemical directions regarding dilution and mixing. Do not
use harsh chemicals; they may damage seals in pumps and valves, and cause the pump to wear
prematurely. NOTE: Never put water in the tank with a temperature exceeding 54
°
C/130
°
F.
4. Pre-spray the area to be cleaned with a pump-up sprayer. Follow chemical directions.
5. Plug in the power cord. Turn on the high pressure pump by placing the HIGH PRESSURE/HEAT selection
switch (2) in the UP position, to select the High Pressure Pump. NOTE: The high pressure pump and
the heat can not operate at the same time. NOTE: this switch is off when it is set to the middle
position and neither the high pressure pump nor the heater is selected.
6. The 85 bar pump is not self-priming; you will need to prime the high pressure pump using the ‘power
prime’ system: turn on both the pump and the vacuum, cover the hole in the hose barb with your
hand, then depress the Power Prime Pedal. This will pull trapped air out of the pump and into the
recovery tank
, priming the pump. You will notice a ‘tone’ change in the pump (smoother, with less of a
rattle), and the water being pulled into the recovery tank will change from a white, full of air stream of
continue on next page
CAUTION: IF FOAM OR WATER COMES OUT THE VACUUM EXHAUST,
TURN THE MACHINE OFF IMMEDIATELY
CAUTION
: Never leave the 85 bar pump running if you are not actively using it
water to a clear, solid stream. Priming may take 20 - 60 seconds, or even longer sometimes, and it will
require a
full solution tank. When the pump is primed, let off the Power Prime Pedal, and turn off the
pump and the vacuum. Then press the Power Prime Pedal once again, for a moment,
to release the line
pressure; you will hear a ‘swoosh’ of air as the back pressure in the lines is released. The pump will need
to be primed anytime air gets into it -- try not to let the pump run dry. Proceed to the next step.
7. Add defoamer to the recovery tank.
8. Attach the solution spray hose to the solution quick disconnect. Attach the vacuum hose to the hose
barb on the front of the recovery tank. Pull the hoses out from the reel. Attach the other ends of the
hoses to the cleaning tool.
9. If you choose to use the automatic pump-out feature, MAKE SURE THE CAP IS REMOVED FROM THE
HOSE CONNECTION ON THE BACK OF THE MACHINE BEFORE YOU TURN THE SWITCH ON. This
pump will run continuously once you turn it on, and if it tries to pump out water, but the cap is still on the
hose fitting, the pump may be damaged.
10. Turn on the vacuum (3) and turn on the dump pump (if you chose to use this feature) (5). Begin
spraying. If you are not using the auto-fill or auto-dump features, turn off the pump and vacuum when
the solution tank gets low; fill the solution tank, and empty and clean the recovery tank. If you use the
auto-fill and/or auto-dump features, you will not need to stop working to fill and/or empty your tanks.
11. When the job is finished, turn off the automatic pump-out pump turn and turn off the water source, if
they were employed. Use the vacuum hose to suck the remaining solution from the holding tank into the
recovery tank.
13. Run a few gallons of clean water through the system. Completely empty the recovery tank by placing the
drain hose over a floor drain, toilet, or tub, and removing the cap. You can clean the tank at this time with
clean water. When the tank is empty, cap the drain hose and place it back in the hook and loop holder.
Disconnect the hoses from the cleaning tool, and reel them up onto the hose spool.
14. Unplug the power cord. Clean the machine and the tool.
LOW PRESSURE AND HEAT
1 Before each use, inspect the machine, hoses, and cleaning tools for cleanliness and completeness. Make
sure hoses are in good condition and the spray nozzle(s) is tight.
REFER TO THE AUTO-FILL AND AUTO-DUMP INSTRUCTIONS ON THE FOLLOWING PAGE
2. If you choose to use the automatic pump-out feature, connect the dump hose to brass hose fitting on
the back of the machine, and place the open end of the hose in a drain. NOTE: NEVER TURN ON THE
PUMP OUT PUMP UNTIL YOU HAVE REMOVED THE CAP FROM THE HOSE CONNECTOR ON THE REAR
OF THE MACHINE. Make sure the drain hose on the back of the vacuum tank is closed and the lid is tight
on the recovery tank. If you are not going to use the auto pump-out option, just make sure the brass
cap is on the hose connector on the rear of the machine.
HIGH PRESSURE continued
continue on next page
CAUTION: if foam or water comes out the vacuum exhaust, turn
the machine off immediately
3. If you choose to use the auto-fill feature, connect the fill-hose to the hose connection over the solution
tank fill hole. Turn on the water source, and allow the tank to fill with solution. NOTE: do not turn the
water on to full pressure; water flowing into the auto-fill system does not need a lot of pressure behind it.
If you choose not to use the auto-fill system, just fill the tank with water and cleaning chemical. Follow
chemical directions regarding dilution and mixing. Do not use harsh chemicals as they may damage seals
in pumps and valves, and cause the pump to wear prematurely. NOTE: using warm water in the tank
may improve the efficiency of the heat exchanger when cleaning with heat, but never use water with a
temperature exceeding 54
°
C/130
°
F.
4. Select ‘HEAT” by moving the HEAT/HIGH PRESSURE switch towards the thermometer symbol. NOTE:
this switch is off when it is set to the middle position and neither the high-pressure pump nor the heater is
selected. When set to the bottom position, the heat is selected; the red light will come on and stay on.
The heater and the high-pressure pump can not operate at the same time.
5. Plug in the power cord.
6. Press the ‘power prime’ pedal (located on the rear, lower left of the machine) for a moment to release
any back pressure in the pump lines.
7. Connect the solution hose to the quick disconnect on the short hose from the 7 bar pump on the front
of the base, and connect the vacuum hose to the hose barb on the top, left of the recovery tank.
Connect the other ends of both hoses to the cleaning tool.
8. Turn on the 7 bar “demand” pump (4). NOTE: the ‘demand’ pump will not run until pressure is
released.
9. Spray for a few seconds to fill the lines with solution. Wait two minutes to allow the heater to reach
temperature.
10. Begin cleaning. It may take several cycles to heat the lines and the cleaning tool.
11.If you are not using the auto-fill or auto-dump features, turn off the pump and the vacuum when the
solution tank gets low. Fill the solution tank, and empty and clean the recovery tank. If you are using
the automatic features, your machine will empty and fill itself -- no need for you to stop working.
12.When finished with the job, turn off the water source, if using the auto-fill feature. Remove the auto-fill
hose from the hose connection on the machine. Vacuum the remaining solution from the solution holding
tank into the recovery tank. Run a few gallons of clean water through the system. Drain the
recovery tank by placing the drain hose over a floor drain, toilet, or tub and removing the cap. You can
clean the tank at this time with clean water. When the tank is empty, cap the drain hose and place it
back in the hook and loop holder. Disconnect the hoses from the cleaning tool, and reel them up onto the
hose spool.
13.Unplug the power cords. Clean and dry the machine and the tool.
LOW PRESSURE AND HEAT continued
NOTE: before servicing any component in the base cabinet, remove the hoses and spool
before opening the tanks. Refer to the instruction on page 3.
DANGER: always unplug the machine from the electrical outlet(s) before
cleaning or maintaining.
Operation:
1. Attach a garden hose to the auto-fill hose connection above the holding tank fill hole, and connect the
other end of the hose to your water source.
2. Make sure the float that hangs into the solution tank from the auto-fill valve is free of obstruction and
can move freely.
3. Turn on the water supply. Do NOT turn the water on full pressure. This system does not require a
high pressure water source. Just turn the water on.
4. The float for the automatic fill will shut-off the flow of incoming water when the tank is nearly full, and
it will allow the valve to open again once the water level has dropped to a predetermined level.
USING THE AUTOMATIC-FILL AND/OR AUTOMATIC-DUMP
AUTOMATIC-FILL INSTRUCTIONS
AUTOMATIC-FILL
Water Hose
Connection
High
Pressure
Outlet
-9-
11600205211REVA
1. Before each use: if necessary, unscrew the stainless steel filter inside the recovery tank and clean it.
Also make sure the float in the recovery tank is clean.
2. Attach a garden hose to the automatic pump-out fitting on the back of the base of the machine (refer
toillustration below).
3. Run the other end of the hose into a drain.
4. Turn on the switch for the automatic pump-out (switch is located on the switch panel on the top of the
machine).
NOTE: the pump out pump is ‘self-priming.’ When there is water in the recovery tank, it will automatically
pump out.
After each job, run clear water though the automatic pump-out to wash out any chemical residue.
Remove and clean the stainless steel filter in the back of the tank. Reinstall the filter once it is clean.
Empty and clean the recovery tank. Disconnect and roll up the dump hose. Clean and dry the
machine and accessories.
AUTOMATIC-DUMP INSTRUCTIONS
DANGER: DO NOT USE SOLVENTS, OR ANY CHEMICALS THAT MAY BE FLAMMABLE,
EXPLOSIVE, OR COMBUSTIBLE.
CAUTION: always use a defoamer in the recovery tank to prevent water or foam from
entering the vacuum motor.
Dump
Pump
Power
Prime
Pedal
Power
Prime
Valve
AUTOMATIC-DUMP
Operation:
Hose
Connection
23
2
3
4
5
6
7
8
9
10
12
14
17
13
15
20
37
25
23
32
28
18
30
20A
11
1
29
26
16
21
27
31
21A
22
34
24
19
HSC 585 Multi
REV A 3.8.08
ALWAYS USE ONLY ORIGINAL NILFISK PARTS ON YOUR HSC 585 MULTI
HSC 585 MULTI
PART LIST
220 - 240V
1 1 600758501 Reel with hoses, complete
2 1 600758502 Lid kit
3 1 600758503 Vacuum air inlet kit
4 1 600758504 Switch plate kit
5 1 600758505 Switch and light kit
6 1 600758506 Auto-fill kit
7 1 600758516 Vacuum tank
8 1 600758508 Heater outlet kit
9 2 600758509 Cord wrap kit
10 1 600758510 Solution tank
11 1 600758511 Fuse kit
12 1 600758512 Water inlet filter kit
13 1 600758513 Power prime kit
14 1 600758514 Drain hose kit
15 1 600758515 Power cord kit, EU
1 600758536 Power cord kit, UK
16 1 600758531 Auto-dump pump kit
17 1 600758517 Vacuum motor kit
18 1 600758518 Pump kit, 7 bar
19 1 600758519 Pump and motor, complete, 85 bar
20 1 600758520 Pump complete, 85 bar, no motor
20A 1 600758544 Pressure regulator, unloader valve
21 1 600758541 Relay kit, vacuum motor
21A 1 600758542 Relay kit, pump motor
22 1 600758522 Base
23 1 600758523 Pressure gauge kit
24 1 600758524 Glide kit, for reel
25 1 600758525 Heat exchanger replacement kit
26 1 600758526 Heat repair kit
27 1 600758527 Low pressure pump outlet kit
28 1 600758528 Castor kit (2)
29 1 600758529 Louver kit
30 1 600758530 Wheel kit (2)
31 1 600758538 RFI filter kit
32 1 600758532 Latch kit
33 1 600758537 Motor, no pump (85 bar)
34 1 600758545 Internal water hoses, kit
ITEM QTY PART No. DESCRIPTION
MISCELLANEOUS PARTS AND KITS
1 600758521 Pump rebuild kit
1 600758533 Vacuum hose kit, for reel
1 600758534 Solution hose kit, for reel
1 600758535 Label kit
1 600758540 Water inlet filter bag (4 in kit)
1 600758545 Hardware kit, complete
ACCESSORIES
HFT-40
TURBO HARD SURFACE
TOOL
Use on all types of hard flooring
Cleaning capacity is up to 93 m
2
or 1000 ft
2
/Hr
Lightweight, but robust
Brush ring attachment
No wheels to restrict 360° travel
Water temperature up to 110 °C / 230 °F
Patented automatic vacuum compensator
leaves the floor dryer
In line filter keeps spray jets clean
HFT-45
HARD SURFACE
COMBO TOOL
Designed for edging hard surfaces
Hose is rated to 172 bar / 500 -2500 psi
Use water up to 110 °C / 230°F
Heads lay flat for cleaning under fixtures
Ergonomic design
HFT-43
MINI TURBO HARD
SURFACE TOOL
Great fo getting in those small areas
35 to 172 bar / 500 -2500 psi
Use it on floors or walls
Lightweight but sturdy
No wheels to restrict 360° travel
Water temperature up to 110 °C / 230 °F
600305899
60070045
60070043
STAINLESS STEEL HAND TOOL
Use it with up to 27 bar / 400 psi
Durable
Reliable valve
Optional in-line filter available
600203099
HOOK AND LOOP STRAP
600709908
Connect the filter to the water inlet of most
tools
Prevents plugged spray jets
Comes apart for cleaning
IN-LINE FILTER
600709906
Connect the filter to the water inlet of most
tools
Prevents plugged spray jets
Comes apart for cleaning
EVOLUTION CARPET WAND
Use it with the 7 bar/100 psi pump on carpets
Its light weight is less fatiguing
It recovers more water from the carpet than
heavier wands
Use with heated water up to 100 °C / 215°F
600203099
-13-
11600205211REVA
NOTES:
HSC 585 MULTI
Vacuum:
Rated Power:
Pump:
Suction Power:
Vacuum at Nozzle:
Heat:
Suction Width:
Weight:
Dimensions:
3-stage
2950 W maximum
Positive displacement, 83 bar & Demand,7 bar
372 W
30.4 KPA
to 100
ºC
38 mm
89.5 KG
39”H x 21”W x 36” L
SPECIFICATIONS:
11-600205211REVA
11600205211REVA
INFORMACIÓN E
INSTRUCCIONES
DE USO
PRECAUCIÓN: NO UTILICE LA MÁQUINA HASTA
HABER LEÍDO TODAS LAS SECCIONES DE ESTE
MANUAL DE INSTRUCCIONES
26022008
EXTRACTOR HSC
585 MULTI
220 - 240 V EU
Para reducir el riesgo de incendios, descargas eléctricas o lesiones:
No pierda de vista la máquina mientras esté enchufada. Desenchufe la unidad de la toma de
corriente cuando no la utilice.
Desenchufe la máquina de la toma de corriente antes de limpiarla o someterla a reparaciones o
mantenimiento.
Apague todos los controles antes de desenchufar.
Para evitar descargas eléctricas, no la deje expuesta a la lluvia o la nieve. Guárdela y use en lugares
cubiertos.
Use protección auditiva si lo desea. El nivel de sonido medido del HSC585 es de 75 dB(A).
No permita que se utilice como juguete. Es necesario prestar mucha atención si se usa cerca de
niños.
Use únicamente como se describe en este manual. Utilice únicamente los accesorios
recomendados por el fabricante.
Inspeccione regularmente el cable de alimentación por si presenta daños, como grietas, deterioro por
envejecimiento o daños en el aislamiento. No utilice si observa daños en el cable o el enchufe. Si hay
que sustituir el cable, lleve la máquina a un centro de servicio técnico autorizado de Nilfisk.
Si el cable o las clavijas del enchufe se dañan, haga que las cambie un técnico de servicio técnico o
socio autorizado de Nilfisk.
Utilice un desespumante en cualquier momento en el que descubra espuma en el depósito de
recogida para evitar daños en el motor.
Si sale espuma o líquido del motor de aspiración o el escape, apague la máquina inmediatamente.
Si la máquina no funciona correctamente, se ha caído, ha sufrido daños, se ha dejado a la intemperie
o se ha inundado de agua, llévela a un centro de servicio técnico.
No tire de la máquina por medio del cable, no utilice el cable a modo de asa, evite que el cable quede
atrapado al cerrar puertas y no tire del cable contra bordes afilados o esquinas. No haga pasar la
máquina por encima del cable. Mantenga el cable alejado de superficies calientes. Para desenchufar,
agarre el enchufe y no el cable.
No manipule el enchufe, el cable ni la máquina con las manos húmedas.
Los alargadores deben ser de 12/3 y su longitud no debe superar los 15,24 m. Sustituya el cable o
desenchufe inmediatamente si la clavija de tierra está dañada.
No coloque ningún objeto en las aberturas. No utilice si las aberturas están obstruidas; manténgalas
libres de polvo, hilos, pelo o cualquier otra sustancia que pueda reducir el caudal de aire.
No aspire ningún material en combustión o que eche humo, como cigarrillos, cerillas, cenizas
calientes o cualquier tipo de polvo que represente una amenaza para la salud. No utilice para recoger
líquidos inflamables o combustibles, como gasolina, ni en lugares en los que pueda haber dichos
líquidos.
Tenga un cuidado especial al limpiar en escaleras.
Enchufe únicamente a una toma de corriente debidamente conectada a tierra.
El líquido que sale podría ser peligroso debido a su temperatura, presión o contenido químico.
No deje que la bomba funcione en seco. Si se queda sin agua, apague la máquina y rellene.
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Esta máquina es apta únicamente para su uso comercial; por ejemplo, en hoteles, colegios, hospitales,
fábricas, tiendas y oficinas, y no para limpieza doméstica habitual.
Cuando utilice un aparato eléctrico, se deben repetar unas precauciones básicas, que incluyen las siguientes:
NOTA: lea todas y cada una de las instrucciones antes de utilizar la máquina.
¡ADVERTENCIA!
11600205211REVA
INSPECCIÓN:
Saque su HSC 585-MULTI del embalaje e inspecciónelo atentamente, y observe si ha sufrido
daños durante el transporte. Todas las máquinas se prueban e inspeccionan antes de su envío.
Cualquier daño producido durante el transporte es responsabilidad del transportista. Si observa
daños en la caja, la máquina o sus piezas, debe notificarlo al transportista inmediatamente.
SOLUCIONES DE LIMPIEZA:
Seleccione una pulverización previa adecuada para la superficie a limpiar, y aplique la misma. Use
un producto de aclarado o detergente neutro (pH de entre 6 y 9) en el HSC 585 para evitar un
desgaste prematuro de la bomba, las juntas y demás componentes. No se recomiendan productos
químicos en polvo.
MANTENIMIENTO:
Para lograr un rendimiento óptimo, limpie la máquina con agua limpia al final de cada jornada
laboral. Una vez al mes, como mínimo, haga pasar un compuesto de limpieza por la máquina para
deshacer cualquier acumulación de minerales o productos químicos que pueda haberse formado
en las conducciones, las bombas o el calefactor.
El motor de aspiración, el motor de la bomba y la propia bomba no necesitan ningún mantenimiento
programado; sin embargo, puede ser necesario cambiar las escobillas de los motores tras 1000-
1500 horas de funcionamiento, y la bomba de alta presión y la válvula del descargador pueden
requerir kits de reparación tras 500-1500 horas (consulte la lista de piezas de la máquina para
conocer los números). Limpie el cuerpo de la máquina con un detergente multiusos y protéjalo con
cera de automóviles para interiores. Lubrique las ruedas, ruedas pivotantes y desconexiones
rápidas con un espray de silicona multiusos.
Anote aquí el número de serie y el modelo de su nuevo extractor:
Modelo:
HSC 585-Multi_ Número de serie: __________________
Fecha de compra:
_____________
Escriba el nombre y el número de teléfono de su distribuidor:
_____________________________________
_____________________________________
NOTA: para retirar de la máquina toda la bobina con tubos, suelte el tubo de aspiración de la
lengüeta en el frontal del depósito y empuje el trozo corto del hubo de aspiración en el centro de la
bobina de tubos. Desconecte el acoplamiento rápido del tubo de la solución. Tome la bobina por
ambos lados y elévela para sacarla de la máquina.
NOTA: antes de realizar cualquier reparación o tarea de mantenimiento en el cuadro de la base,
retire los tubos y la bobina de la máquina antes de abrir los depósitos.
O
I
I
I
O
O
I
I
PLACA DE
INTERRUPTORES
5
LUZ DE LA BOMBA
DE ALTA PRESIÓN
(SIN CALOR)
INTERRUPTOR
DE ENCENDIDO/
APAGADO DE LA
BOMBA DE
VACIADO
INTERRUPTOR
SELECTOR DE
BOMBA/CALOR
INTERRUPTOR DE
ENCENDIDO/
APAGADO DE LA
BOMBA DE 100 PSI
3
INTERRUPTOR DE
ENCENDIDO/
APAGADO DE LA
ASPIRACIÓN
2
4
LUZ DE CALOR
SELECCIONADO
CONOZCA SU MÁQUINA
HSC 585 MULTI
Interruptores.
Desconexión
rápida de 85
bar
Tubos
Conexión del tubo
de aspiración
Compartimento de base
Depósito de
aspiración
Pestillo
Desconexión rápida de 7 bar
Depósito de
la solución
Rueda
Tapón del tubo de
drenaje
Soporte de varilla
Tapa del
depósito de
aspiración
Rueda pivotante con freno
Manómetro
Rueda
Pedal de
cebado
eléctrico
Conector para
manguera de
jardín
Tubo de drenaje
Bomba de
vaciado
automático
Cable de
alimentación
FUNCIONAMIENTO
CONSULTE LOS DIAGRAMAS DE LA PÁGINA ANTERIOR.
LIMPIEZA CON ALTA PRESIÓN
1 Antes de cada uso, inspeccione si la máquina, los tubos y las herramientas de limpieza están limpios y
completos. Asegúrese de que los tubos están en buen estado y las boquillas de pulverización están bien
ajustadas.
CONSULTE LAS INSTRUCCIONES DE LLENADO AUTOMÁTICO Y VACIADO AUTOMÁTICO EN LAS
SIGUIENTES PÁGINAS.
2. Si decide utilizar la función de vaciado automático, conecte el tubo de vaciado al accesorio para tubos de
latón en la parte posterior de la máquina, y coloque el extremo abierto del tubo en un desagüe. Asegúrese
de que el tubo de drenaje en la parte posterior del depósito de aspiración está cerrado y la tapa bien
ajustada sobre el depósito de recuperación. NOTA: nunca encienda el interruptor de vaciado automático si
no ha retirado el tapón de latón del conector para tubos de la parte posterior la máquina. Esta bomba
funcionará de forma continua si se enciende, y si el agua no puede sacarse (tapón todavía atornillado) la
bomba puede resultar dañada.
Si decide utilizar la opción de vaciado automático, sólo asegúrese de que el tapón de latón está en el
conector para tubos de la parte posterior la máquina. PRECAUCIÓN: no encienda el interruptor de vaciado
automático si el tapón de latón sigue en el conector para tubos de la parte posterior la máquina.
3. Si opta por usar la función de llenado automático, conecte el tubo de llenado a la válvula de llenado
automático (situada sobre el orificio de llenado del depósito de la solución). Encienda la fuente de agua.
NOTA: no encienda el agua a máxima potencia. El agua que se introduce en el sistema de llenado
automático no necesita mucha presión. Deje que el depósito se llene con solución. Cuando use el sistema
de llenado automático, la válvula de llenado automático se enciende y se apaga automáticamente a
medida que el depósito se vacía y luego se llena. NOTA: si no va a usar el sistema del llenado automático,
simplemente llene el depósito con agua y producto químico de limpieza. Siga las instrucciones de los
productos químicos relativas a la mezcla y la disolución. No utilice productos químicos agresivos; pueden
dañar las juntas en bombas y válvulas y provocar desgaste prematuro en las bombas. NOTA: nunca
ponga agua en el depósito con una temperatura que supere los 54
°
C.
4. Pulverice previamente el área a limpiar con un pulverizador de bombeo. Siga las instrucciones de los
productos químicos.
5. Enchufe el cable de alimentación. Encienda la bomba de alta presión colocando el interruptor de selección
ALTA PRESIÓN/CALOR (2) en la posición de arriba para seleccionar la bomba de alta presión. NOTA: la
bomba de alta presión y el calor no pueden funcionar a la vez. NOTA: este interruptor está apagado
cuando se coloca en la posición media y no se ha seleccionado la bomba de alta presión ni el calefactor.
6. La bomba de 85 bar no tiene autocebado; deberá cebar la bomba de alta presión mediante el sistema de
cebado eléctrico”: encienda la bomba y el vacío, cubra el orificio en la lengüeta del tubo con su mano,
luego pise el pedal de cebado eléctrico. Con esto se sacará el aire atrapado en la bomba al depósito de
recuperación, con lo que se ceba la bomba. Se aprecia un cambio de “tono” en la bomba (más suave, con
menos traqueteo), y el agua que se introduce en el depósito de recuperación cambia de un chorro de agua
blanco y lleno de aire a un chorro uniforme y transparente. El cebado puede llevar entre 20 y 60 segundos,
o incluso más algunas veces, y requerirá un depósito de la solución
lleno. Cuando la bomba esté cebada,
suelte el pedal de cebado eléctrico y apague la bomba y la aspiración. Luego vuelva a presionar el pedal de
cribado eléctrico una vez más, durante un instante, para
reducir la presión de las conducciones;
sigue en la siguiente página
PRECAUCIÓN: SI SALE ESPUMA O LÍQUIDO DEL ESCAPE DE LA
ASPIRACIÓN, APAGUE LA MÁQUINA INMEDIATAMENTE.
PRECAUCIÓN
: nunca deje la bomba de 85 bar en funcionamiento si no la está usando de forma activa.
escuchará el “zumbido” del aire a medida que se reduce la contrapresión en las conducciones. Es
necesario cebar la bomba en cualquier momento que se introduzca aire en ella; no deje que la bomba
funcione en seco. Continúe con el siguiente paso:
7. Añada desespumante al depósito de recuperación.
8. Conecte el tubo de pulverización de solución a la desconexión rápida de la solución. Acople el tubo de
aspiración a la lengüeta del tubo en el frontal del depósito de recuperación. Saque los tubos de la bobina.
Acople los otros extremos de los tubos a la herramienta de limpieza.
9. Si deciden utilizar la opción de vaciado automático, ASEGÚRESE DE QUE EL TAPÓN ESTÁ QUITADO
DE LA CONEXIÓN PARA TUBOS DE LA PARTE POSTERIOR DE LA MÁQUINA ANTES DE ENCENDER
EL INTERRUPTOR. La bomba funcionará de forma continua una vez encendida, y si intenta sacar agua
pero el tapón está puesto en el accesorio para tubos, la bomba puede resultar dañada.
10. Encienda la aspiración (3) y la bomba de vaciado (si decide utilizar esta función) (5). Comience la
pulverización. Si no usa las funciones de llenado automático o vaciado automático, apague la bomba y la
aspiración cuando el depósito de la solución esté bajo, llene dicho depósito y vacíe y limpie el depósito de
recuperación. Si usa las funciones de llenado automático y/o vaciado automático, no es necesario dejar de
trabajar para llenar o vaciar sus depósitos.
11. Cuando termine el trabajo, apague la bomba de vaciado automático y la fuente de agua, si se han utilizado.
Use el tubo de aspiración para recoger la solución restante del depósito de retención y ponerla en el
depósito de recuperación.
13. Haga correr algunos litros de agua limpia por el sistema. Vacíe por completo el depósito de recuperación
colocando el tubo de vaciado sobre un desagüe del suelo, un retrete o una bañera, y retire el tapón del
tubo. Puede aprovechar este momento para limpiar el depósito con agua limpia. Cuando el depósito esté
vacío, ponga el tapón en el tubo de vaciado y vuelva a ponerlo en el soporte con gancho y seguro.
Desconecte los tubos de la herramienta de limpieza y enróllelos en su bobina.
14. Desenchufe el cable de alimentación. Limpie la máquina y la herramienta.
BAJA PRESIÓN Y CALOR
1 Antes de cada uso, inspeccione si la máquina, los tubos y las herramientas de limpieza están limpios y
completos. Asegúrese de que los tubos están en buen estado y las boquillas de pulverización están bien
ajustadas.
CONSULTE LAS INSTRUCCIONES DE LLENADO AUTOMÁTICO Y VACIADO AUTOMÁTICO EN LA
SIGUIENTE PÁGINA.
2. Si decide utilizar la función de bombeo automático, conecte el tubo de vaciado al accesorio para tubos de
latón en la parte posterior de la máquina, y coloque el extremo abierto del tubo en un desagüe. NOTA:
NUNCA ENCIENDA LA BOMBA DE VACIADO HASTA HABER RETIRADO EL TAPÓN DEL CONECTOR
PARA TUBOS DE LA PARTE POSTERIOR DE LA MÁQUINA. Asegúrese de que el tubo de drenaje en la
parte posterior del depósito de aspiración está cerrado y la tapa bien ajustada sobre el depósito de
recuperación. Si decide no utilizar la opción de vaciado automático, únicamente asegúrese de que el tapón
de latón está en el conector para tubos de la parte posterior de la máquina.
3. Si opta por usar la función de llenado automático, conecte el tubo de llenado a la conexión de llenado
situada sobre el orificio de llenado del depósito de la solución. Encienda la fuente de agua y deje que el
depósito se llene con solución. NOTA: no encienda el agua a máxima presión; el agua que se introduce en
ALTA PRESIÓN (sigue)
sigue en la siguiente página
PRECAUCIÓN: si sale espuma o líquido del escape de la aspiración,
apague la máquina inmediatamente.
el sistema de llenado automático no necesita mucha presión. Si decide no usar el sistema del llenado
automático, simplemente llene el depósito con agua y producto químico de limpieza. Siga las instrucciones
de los productos químicos relativas a la mezcla y la disolución. No utilice productos químicos agresivos, ya
que pueden dañar las juntas en bombas y válvulas y provocar desgaste prematuro en la bomba. NOTA: el
uso de agua tibia en el depósito puede resultar beneficioso para la efectividad del intercambiador de calor
durante la limpieza, pero nunca utilice agua con una temperatura que supere los 54
°
C.
4. Seleccione HEAT (calor) moviendo el interruptor HEAT/HIGH PRESSURE (calor/alta presión) hacia el
símbolo del termómetro. NOTA: este interruptor está apagado cuando se coloca en la posición media y no
se ha seleccionado la bomba de alta presión ni el calefactor. Cuando se coloca en la posición inferior, se
selecciona el calor; la luz roja se enciende y permanece encendida. El calefactor y la bomba de alta
presión no pueden funcionar a la vez.
5. Enchufe el cable de alimentación.
6. Presione el pedal de cebado eléctrico (situado en la parte posterior inferior izquierda de la máquina) un
instante para reducir cualquier contrapresión en las conducciones de bombeo.
7. Conecte el tubo de la solución a la desconexión rápida en el tubo corto que sale de la bomba de 7 bar, en
el frontal de la máquina, y conecte el tubo de aspiración a la lengüeta de tubos en la parte superior
izquierda del depósito de recuperación. Conecte los otros extremos de ambos tubos a la herramienta de
limpieza.
8. Encienda la bomba de demanda de 7 bar (4). NOTA: la bomba “por demanda” no funciona hasta que se
reduce la presión.
9. Pulverice durante unos pocos segundos para llenar las conducciones con solución. Espere dos minutos
para que el calefactor alcance la temperatura adecuada.
10. Comienzo de la limpieza. Calentar las conducciones y la herramienta de limpieza puede requerir algunos
ciclos.
11. Si no usa las funciones de llenado automático o vaciado automático, apague la bomba y la aspiración
cuando el depósito de la solución esté bajo. Llene dicho depósito de la solución y vacíe y limpie el depósito
de recuperación Si usa las funciones automáticas, su máquina se vaciará y se llenará por sí misma, no
es necesario dejar de trabajar.
12. Cuanto termine el trabajo, apague la fuente de agua si utiliza la función de llenado temático. Retire el tubo
de llenado automático de la conexión para tubos de la máquina. Aspire la solución restante del depósito de
retención al depósito de recuperación. Haga correr algunos litros de agua limpia por el sistema. Vacíe el
depósito de recuperación colocando el tubo de vaciado sobre un desagüe del suelo, un retrete o una
bañera, y retire el tapón del tubo. Puede aprovechar este momento para limpiar el depósito con agua
limpia. Cuando el depósito esté vacío, ponga el tapón en el tubo de vaciado y vuelva a ponerlo en el soporte
con gancho y seguro. Desconecte los tubos de la herramienta de limpieza y enróllelos en su bobina.
13. Desenchufe los cables de alimentación. Limpie y seque la máquina y la herramienta.
BAJA PRESIÓN Y CALOR (sigue)
NOTA: antes de realizar cualquier reparación o tarea de mantenimiento en el cuadro de la base,
retire los tubos y la bobina de la máquina antes de abrir los depósitos. Consulte las instrucciones de
la página 3.
PELIGRO: desenchufe siempre la máquina de las tomas de corriente eléctrica
antes de su limpieza o mantenimiento.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104

Nilfisk HSC585 Bruksanvisning

Typ
Bruksanvisning
Denna manual är också lämplig för