FLOW FL-100 Depression Treatment Headset Användarmanual

Typ
Användarmanual
MANUAL
USER
Model: FL-100
START BY DOWNLOADING THE APP FLOW  DEPRESSION TREATMENT
English ...................................... 2
Swedish - Svenska .......................18
Danish - Dansk ...........................34
Dutch - Nederlands .....................50
Finnish - Suomi ..........................66
French - Français ........................82
German - Deutsch ......................98
Norwegian - Norsk .................... 114
Português: Do Brasil .................. 130
Português: Europeu .................. 146
Caution: Do NOT use this device without first
consulting a doctor or other health care professional. !
2 / ENGLISH ENGLISH / 3
ENGLISH
Get started by downloading the app
“Flow - Depression treatment”
2 / ENGLISH ENGLISH / 3
Table of Contents
1. Manufacturer ...........................................................4
2. Intended Use ...........................................................4
3. Box Contents & the Headset ...............................4
4. Accessories ...............................................................5
5. Precautions ..............................................................6
6. Warnings ...................................................................7
7. Possible Adverse Reactions .................................8
8. Prerequisites ............................................................9
9. The Treatment Programme .................................9
10. First-Time Use ..........................................................9
11. How to Perform a Treatment Session ............ 10
12. Charging the Headset .........................................12
13. Cleaning of the Headset.....................................13
14. Device Specications ..........................................14
15. Markings.................................................................15
16. Product Disposal ..................................................16
17. Contact Us ............................................................. 16
18. EMC - Test Results .............................................162
4 / ENGLISH ENGLISH / 5
Flow Neuroscience AB
Södra Tullgatan 3, 211 40 Malmö, Sweden
Flow is a class IIa Medical Device intended for home-
based treatment of adults (18+) diagnosed with Major
Depressive Disorder (MDD).
Flow does not require any special training before use.
3. Box Contents
& the Headset
1. Instructions for Use
2. Micro-USB Charger & cord
3. Two Pad Holder Rings
4. Flow Headset
Instructions on how to use the Flow headset and the
accompanying smartphone app.
IFU Version and Issuing date: Ver 16.02 - 2023-04-17
Product model: FL-100
The latest version of this manual is also available to
download from flowneuroscience.com
1. Manufacturer
2. Intended Use
Instruction for Use – Flow
2
1
3
4
4 / ENGLISH ENGLISH / 5
5. Metal arch
6. Pads
7. Electrodes
8. Button
9. LED indicator
10. Charger port cover
11. Back piece
After each use, put the headset and other parts back in
the box.
ITEMS DEFINITION
HEADSET PADS A BOX OF FLOW PADS CONTAINING
20 POUCHES SINGLE USE
MICRO USB CHARGER A LXCP12005 CHARGER AND CORD
4. Accessories
More Pads can be ordered online at flowneuroscience.com
11
10
89
7
5
6
3
Reuse of pads may cause skin damage. Always start a
stimulation session with a new pair of Headset pads.
6 / ENGLISH ENGLISH / 7
5. Precautions
Pregnancy (or suspected pregnancy)
Suicidal thoughts (thoughts about ending your life)
Bipolar disorder (or having a history of hypomanic/
manic episodes)
Epilepsy (or having a history of seizures)
Heart disease (or suspected heart disease)
A neurological or neuropsychiatric condition
Having recently had a surgical procedure
Having a defect in neurocranium and/or an implant
inside the skull
Using this device poses minimal risk of injury. Even so, it
is recommended to consider multiple treatment options.
If symptoms worsen, make sure to contact a healthcare
professional.
The Flow device should only be used by people over 18
years of age who have been diagnosed with depression
(Major Depressive Disorder).
Always consult a physician before making any changes to
your current medication.
Take extra precaution and make sure to consult your
physician under the following circumstances:
Caution: Do NOT use this device without first
consulting a doctor or other health care professional. !
6 / ENGLISH ENGLISH / 7
Having an active, implanted medical device (e.g. cardiac
pacemaker, spinal cord stimulator, vagal nerve stimulator,
auricular stimulator, deep-brain stimulating electrodes,
cochlear implant, implanted hearing aid or defibrillator)
or other implanted metallic or electronic device.
6. Warnings
Apply the headset ONLY on the head as directed and
not on other body parts.
Keep the headset dry and out of sunlight.
Keep the headset out of the reach of children.
Do not apply the headset over areas of skin that lack
normal sensations.
Do not apply the headset outdoors or close to water.
Do not apply the headset while driving.
Do not apply the headset during any activity creating a
significant risk of injury.
Do not apply the headset while intoxicated or
incapacitated.
Do not apply the headset in environments with strong
magnetic fields.
Do not apply the headset without the supplied Headset
Pads.
Do not apply the headset with dried-out Headset Pads
(Pads are single use).
Do not charge the headset with any other charger than
the one supplied with the headset.
8 / ENGLISH ENGLISH / 9
Worsening of symptoms: If you experience a significant
worsening of your symptoms while using this device,
consult a physician before continuing the treatment.
7. Possible Adverse Reactions
Some skin redness under the electrode or near the
electrode sites is normal, due to increased local blood
flow and will normally subside within approximately an
hour of the end of use.
DO NOT apply the device over open wounds, or
broken or damaged skin. This might create further
irritation and/or skin damage.
Skin irritation might be experienced beneath the
stimulation electrodes. In this case, electrodes should
NOT be reapplied to the irritated skin.
Discontinue treatment if the sensation of tingling,
itching or burning under electrodes becomes severe
(mild sensation of tingling, itching or burning is normal).
Discontinue treatment if you experience a mild
headache that does not pass within an hour after the
end of a session.
Discontinue treatment if you experience tinnitus (noise
or ringing in the ears) during or after using the device.
Discontinue treatment in case of any other adverse
reaction from the device.
NOTE: Any serious incident that has occurred in relation to the
device should be reported to Flow Neuroscience and the local
competent authority.
If you experience any dryness of the skin/skin irritation after
stimulation, it is recommended to apply moisturiser to the area.
8 / ENGLISH ENGLISH / 9
8. Prerequisites
A smartphone or other device running either
Apple iOS 12+ or Android 6.0+.
9. The Treatment Program
The Flow treatment programme consists of 15 sessions
during the first 3 weeks, as shown in the table below.
After this first treatment period, 1-2 sessions are
recommended per week.
The number of sessions you can do per week is
restricted and you can only do 1 per day.
Each session lasts 30 minutes, plus a few minutes of
preparation time.
10. First-Time Use
Download the “Flow - Depression treatment”
app to your mobile device.
Create an account in the downloaded “Flow
- Depression treatment” app using an email
address you have access to and new password
of your choosing.
NOTE: IT security measures, including
protection against unauthorised access, are
secured in accordance with GDPR regulations.
WEEK W1 W2 W3 W4 W5+
No. of sessions 5 5 5 1-2 1-2
10 / ENGLISH ENGLISH / 11
11. How to Perform a Treatment Session
Ensure your forehead is free from any makeup or hair
products before you start.
If you have a fringe, it is recommended that you use a
hair tie to remove it from your forehead.
Take out the headset from the box.
Press the button on the headset and make sure it blinks
twice. If not, charge the headset.
Make sure Bluetooth is enabled on your smartphone.
Start the Flow app and log in with the email address &
password you chose in section 9 above.
Select the next session in the app and press “Start” to
start the session. Note that how often you can use the
headset is restricted per week and day.
Follow the instructions given by the virtual therapist in
the app.
When told to, follow the instructions on how to prepare
the headset, as below:
Take a new pair of Headset
Pads from the pouch.
1.
Attach them to the electrodes
using the Pad Holder Rings.
2.
10 / ENGLISH ENGLISH / 11
Adjust the length of
the metal arch by
sliding the back piece.
3.
The end of the arch
should sit comfortably on
the back of your head.
4.
5.
Make sure the headset does not sit too low.
The app shows you how to correctly position the
headset using the camera on your device.
6. Before starting the stimulation, you can press and hold the
“Tingle” button in the app to test how the stimulation feels.
Hold the “Tingle” button for at least 10 seconds.
7. Start the stimulation by pressing the “Start stimulation” button
in the app.
12 / ENGLISH ENGLISH / 13
NOTE: Most users that experience reduced symptoms of
depression do so within 3-4 weeks. For a summary of safety &
clinical performance, see flowneuroscience.com
The current will now slowly increase to its maximum of
2 mA, as shown in the app.
If you at any point want to pause the stimulation,
press the pause button in the app or the button on the
headset.
Follow the instructions in the app during the rest of the
session. The session will last for 30 minutes.
When the time is up, the headset will automatically
start decreasing the current.
Do not remove the headset before the app indicates
that the stimulation has stopped.
The headset gives a “beep” signal when the
stimulation has finished.
After the session, dispose of the Headset Pads and put
the Pad Holder Rings and headset back in the box.
The headset will automatically turn itself o after a
few minutes of inactivity. Start it again by pressing the
button on the headset.
12. Charging the Headset
Charge the headset if the LED indicator on the front of
the headset does not blink when pressing the button.
12 / ENGLISH ENGLISH / 13
Remove the charger port cover and charge using the
supplied Micro-USB charger and cable.
The LED indicator blinks during charging and shows a
steady light when the headset is fully charged.
Recharging a fully flat battery takes approximately an
hour.
Be sure to close the charger port cover again after
charging.
13. Cleaning of the Headset
It is recommended to clean the headset and especially
the electrodes after each use.
To clean the device, ensure that the Micro-USB cable is
not connected to the headset and remove the pads.
Use an IPA (isopropanol) wet wipe (45% is a good
choice).
Clean the electrodes using a circular motion.
Neither the device nor its accessories are supplied
sterilized nor require sterilization prior to use.
14 / ENGLISH ENGLISH / 15
PERFORMANCE CHARACTERISTICS
PARAMETER NOMINAL VALUE
MAX. STIMULATION CURRENT 2.0 + 0.05 mA
MAX. STIMULATION VOLTAGE 24 V
MICRO-USB CHARGER 5 V D.C.
BATTERY RECHARGEABLE LiPo 3.7 V; 250 mAh
ELECTRODE SIZE 22.9 cm2 (5.4 cm diameter)
DEVICE WEIGHT ~110 g
WATER INGRESS PROTECTION IP22
DEVICE EXPECTED LIFETIME 3 YEARS
OPERATING ENVIRONMENT HOME OR CLINICAL ENVIRONMENT
OPERATING TEMP. RANGE 5 to 35°C (41 to 95°F)
STORAGE/TRANSPORT TEMP.
RANGE -10 to 40°C (14 to 104°F)
OPERATING HUMIDITY RANGE 10% to 93%, NON-CONDENSING
STORAGE/ TRANSPORT
HUMIDITY RANGE 10% to 93%, NON-CONDENSING
OPERATING ALTITUDE RANGE 0 – 3000 m
STORAGE/TRANSPORT
ALTITUDE RANGE 0 – 3000 m
14. Device Specifications
14 / ENGLISH ENGLISH / 15
ICON DEFINITION
Consult Instruction for Use (IFU)
Caution: Consult Accompanying Documentation
Separate collection for electrical
and electronic equipment
per EC Directive 2012/19/EU. Waste Electrical
and Electronic Equipment (WEEE).
Type BF Applied part
Manufacturing Year
Keep Dry
Manufactured by Flow Neuroscience AB
Södra Tullgatan 3, 211 40 Malmö, Sweden,
Web: flowneuroscience.com
IP22 Water ingress protection: 22
Notified Body No.
Bluetooth Low Energy
15. Markings
16 / ENGLISH ENGLISH / 17
16. Product Disposal
Headset Pads are cellulose sponges and can safely be
disposed of as household waste.
The headset and charger should be disposed of as
electronic waste according to the local legislation.
17. Contact Us
If you have any questions regarding Flow, don’t hesitate to
contact customer support at
https://www.flowneuroscience.com/support/
Flow Neuroscience AB
Södra Tullgatan 3, 211 40 Malmö, Skåne län, Sweden
16 / ENGLISH ENGLISH / 17
18 / SVENSKA SVENSKA / 19
SVENSKA
Kom igång genom att ladda hem appen
“Flow - Depression treatment”
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168

FLOW FL-100 Depression Treatment Headset Användarmanual

Typ
Användarmanual