POINT POPANW800B PANELOVN, SVART Bruksanvisning

Typ
Bruksanvisning
POPANW400/ POPANW600 /
POPANW800/ POPANW800B/
POPANW1000/POPANW1000B
User Manual
POLISW800/POLISW1000
User Manual
Thank you for purchasing your new POINT SERIES Panel Heater. These
operating instructions will help you use it properly and safely. We
recommend that you spend some time reading this instruction manual
in order that vou fully understand all the operational features it oers.
Read all the safety instructions carefully before use and keep this
instruction manual for future reference.
Kiitos, kun valitsit uuden POINT-paneelilämmittimen. Nämä
käyttöohjeet opastavat sinua käyttämään laitetta oikein ja
turvallisesti. Suosittelemme, että käytät hieman aikaa tämän
käyttöoppaan lukemiseen, jotta ymmärrät täysin, millaisia toimintoja
laitteessa on. Lue kaikki turvallisuusohjeet huolellisesti ennen laitteen
käyttöä ja säilytä käyttöopas myöhempää tarvetta varten.
POINT SERIES panelovn
POINT-SERIENS Panelvarmer
Panelvärmare i POINT-SERIEN
Instruction Manual - English
Bruksanvisning - Norsk
Brugervejledning - Dansk
Bruksanvisning - Svenska
page
side
side
side
4 - 22
3
23 - 41
42 - 60
61 - 79
80 - 98
4
SAFETY INSTRUCTIONS
Warning: In order to avoid overheating, do not
cover the heater.
Do not use the appliance in areas where flammable
liquids are stored or where flammable fumes may be
present.
This appliance can be used by children 8 years and
older and persons with reduced physical, sensory or
mental capabilities or lack of experience and
knowledge if they are supervised or instructed on the
safe use of the appliance and understand the risks
involved.
Children younger than 3 years should be kept away
unless continuously supervised.
Children aged from 3 to 8 years are allowed only to
switch on/o the appliance provided that it has been
placed or installed in its intended normal operating
position and they are supervised or instructed on the
safe use of the appliance and understand the risks
involved. Children aged from 3 to 8 years are not to
plug in, regulate and clean the appliance or perform
user maintenance.
Children should be supervised to ensure that they do
not play with the appliance.
Do not use this appliance if it has been dropped.
If the mains cable is damaged, it must be replaced by
the manufacturer or its service agent or similarly
qualified person in order to avoid a hazard.
1.
2.
3.
4.
5.
6.
7.
8.
Do not use the appliance if there are visible signs of
damage.
Ensure that your power supply voltage matches
the appliance’s rating label.
Use the appliance on a horizontal and stable surface,
or fix it to the wall, as applicable.
WARNING: Do not use this heater in small rooms
when they are occupied by persons not capable of
leaving the room on their own, unless constant
supervision is provided.
WARNING: To reduce the risk of fire, keep textiles,
curtains, or any other flammable material a minimum
distance of 1 m from the air outlet.
WARNING: this appliance should be installed so that
the bottom of the heater is at least 50 mm above the
floor.
Statement: The appliance is not to be placed
immediately below a socket-outlet.
Always turn o and unplug the appliance when not in
use.
Always unplug the appliance and ensure the
appliance is completely cold before moving, cleaning,
or storing it.
When using this appliance – plug directly into the
wall socket and not via extension cables or other
adaptors as this may cause an overload.
CAUTION — Some parts of this appliance can become
very hot and cause burns. Particular attention has to
be given where children and vulnerable people are
present.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
5
6
PRODUCT OVERVIEW
1.Body
2.Switch
3.Control panel
4.Wall bracket
5.Wall-mounting kits
Description
Screw 4
4Plastic plug
Drawing QTY
123 4
INSTALLATION
185mm 130mmA
B
Min.50mm Min.50mm
Min.50mm Min.50mm
Min.568mm
81mm
Min.175mm
Min.150mm
160mm
368mm Min.150mm
368mm
Model no. Watt A B
POPANW400 150mm 465mm
210mm 525mm
330mm 645mm
420mm
400W
600W
800W
1000W 735mm
POPANW600
POPANW800/POPANW800B
POPANW1000/POPANW1000B
5
7
Fig.1
Fig.2
Model no. Watt A B
POLISW800 490mm 1035mm
670mm 1215mm
800W
1000WPOLISW1000
160mm
A
Fig.3
Min.50mm Min.50mm
250mm Min.150mm
Min.50mm
B
Min.50mm
81mm
250mm
Min.450mm
Min.150mm
Min.140mm
70mm
185mm A265mm
8
To hang the heater on the wall:
Use
CONTROL PANEL
Choose a suitable installation location for the heater. Follow the
minimum distances in all directions (Fig 1). Disassemble the wall bracket
by loosening the screw (not screw o, only loosen) and sliding the metal
pieces out of the hole. Take out the bracket by pulling it down.
Verify that the bracket is perfectly horizontal with a spirit level and mark
the location of holes on the wall. Drill holes in the wall for the pegs with a
suitable drill bit. Insert the pegs into the holes, then screw the wall
mount bracket securely onto the wall (Fig 2).
Place the heater against the bracket. Fix the heater on the 2 downwards
hooks. Pull the heater upwards whilst keeping it in the 2 lower hooks. Fix
the heater on the 2 upwards hooks. Pull the heater down. Slide the 2
metal pieces on top into the hole, and fasten the screws to lock the wall
mount bracket (Fig 3).
1.
2.
3.
Touch icon
/
Function
set the temperature, from 5°C to 35°C, increase/decrease by 1°C
each step.
shift modes (Manual, P1, P2, P3, P4, OF) or confirm.
enter setting menu or to cancel.
9
OPERATION
The first time you plug in, press the on/o switch, the appliance will
show 19°C at manual mode as factory default setting.
Pressing the button will switch the device on or o
If the button is in the down position, the device is on (1).
If the button is in the up position, the device is o (0).
1.
When the temperature of the environment is below the set temperature,
the heater will start to heat the room, otherwise, no.
The heating indicator icon will light on only when the product is heating up.
Temperature adjustment:
Press “+” or “” to set temperature. Min. setting is 5°C, Max. is 35°C.
Pressing and holding “+” or “” makes the adjustment faster.
In the event of a power failure, the heater will resume to work under the
same mode and set temperature after the power is resumed.
Short press OK to shift among the following modes: manual ( ), P1, P2,
P3, P4, OF. (After flashing 5 seconds, the display will show set
temperature.)
Manual: the display will show , press “+” or “-” to select the
temperature manually.
P1-P4 mode: the default programs are as below. Among them, P1 to P3
are fixed pre-set programs while P4 is a free weekly personalized
program.
OF mode: the display show OF. During this mode, the appliance doesn’t
heat up but clock settings are maintained.
2.
3.
Power
switch
Time setting
10
Short press or keep pressing the “+” / “-” icon to change the set tempera-
ture. Short press “+” / “-” to adjust the temperature, 1°C each step, the
temperature range is from 5 to 35°C. Keep “+” / “-” pressed to increase/-
decrease the temperature quickly.
Setting menu
Short press “M” icon to enter or exit the setting menu.
The setting menu can be used to show the function list of the appliance:
td: time setting
Pr: P4 (free weekly personalized program)
C: temperature calibration
LI: adjustment of screen brightness
AS: adaptive start function
Press “+” or “-” to select from td (time setting), Pr (P4 free weekly
personalized program), C (temperature calibration), LI (adjustment of screen
brightness).
The selected icon will flash.
Press “M” to select “td”, and short press “OK” to enter time setting interface.
Press “+” / “-” to set the day of week (choose from d1 to d7). Then press “OK”
to save and enter hour setting.
Press “+” / “-” to set the hour (choose from 0 to 23). Then press “OK” to save
and enter minute setting.
Press “+” / “-” to set the minute (choose from 00 to 59). Then press “OK” to
save and go back to the previous working mode and temperature.
You cannot make any other adjustments before setting the day/time.
4.
5.
Weekly
modes
Time and
program
setting
P1 (5-2)
P2 (6-1)
P3 (7-0)
P4 (0-7)
Saturday-Sunday
Sunday
Monday-Sunday
Monday-Friday
Monday-Saturday
Event 2 heating cycles4 heating cycles
Time
period
Factory
setting
Comfort ComfortEco Eco Comfort Eco
21°C 17°C 21°C 17°C 21°C 17°C
Time 6:00-9:00 16:00-23:009:00-16:00 23:00-6:00 7:00-23:00 23:00-7:00
Monday-Sunday
11
P4 free weekly personalized program
Short press "M" to select Pr. Short press “OK" to enter the Pr (P4) free
weekly program setting interface (the default modifiable program is P4).
You can select 2 set temperature points for each hour of the 24 hours of the
day, and each day of the week: COMFORT( ) and ECO( ).
COMFORT( ) is the set temperature value; the temperature value of ECO
( ) is 4°C lower than the set temperature value.
The default day is d1. You can press "+"/"-" to select from
d1/d2/d3/d4/d5/d6/d7 (d1-Monday, d2-Tuesday, d3-Wednesday,
d4-Thursday, d5-Friday, d6-Saturday, d7 -Sunday). Press "OK" to confirm the
day.
The display shows 0 to mean the first hour (0:00-0:59). Short press “+” to
select comfort( ) , “-” to select eco( ), or “OK” to keep the previous
setting. After selecting the working mode for the 1st hour, the appliance will
automatically move to the 2nd hour. Press “+” or “-” or “OK” to select the
working mode of the 2nd hour, and enter the next hour setting. Repeat
above until you select the working mode for the 24th hour (23 is displayed on
the screen) setting. The heater will then automatically go back to the setting
interface of day of the week.
After you finish the setting the day, press “OK” to confirm and repeat same
operation for rest of the days.
After you finish the setting of P4, the display will flash for 30 seconds and
then go back to the setting menu with the display showing “Pr. “Pr” will
then flash for 10 seconds, and then display will go back to the working mode
interface.
To check the whole program of P4, keep “+” & “-” pressed for 5 seconds when
the display shows “Pr. The screen will show the whole program hour by hour
for each day of week.
Temperature calibration setting
Short press “M” to select “C. Short press “OK” to enter C—temperature
calibration setting interface.
“0” will be shown on the display as default. Press “+” / “-” to set the
compensation temperature within ±5°C.
Example: the temperature setting on your heater is 24°C. The heater stops
heating even though your thermometer says the temperature is only 22°C. In
this case, choose the calibration value -2°C.
12
Adjustment of screen brightness:
Short press “M” to select LI. Press “OK” to enter LI—screen brightness
setting interface. You can adjust the brightness of the screen. The default
setting value is 3.
Press “+” / “-” to choose from grade 1 to 5. Grade 1 is the darkest while 5 is
the brightest.
Adaptive start function:
Short press “M” to select “AS”. Press “OK” to enter Adaptive Start setting
interface. The screen will show “on” or “oF”. Press “+” or “-” to change the
selection. When “on” is selected, the Adaptive Start function is activated.
When “oF” is selected, the function is deactivated. Default setting is “oF.
This feature measures the thermal inertia of the room and turns on the
heaters in advance to ensure "comfort" temperature is reached at the set
time. This function can turn on the appliance for heating maximum 2 hours
in advance.
Remarks: This function applies for P1, P2, P3 programs only.
Window detector function
Press “+” & “OK” for 5 seconds to enter the window detector setting with
“ ” flashing. The display will show “on” or “oF. Press “+” or “-” to select. If
on” is selected, the window detector function is activated. When “oF” is
selected, the window detector function will be deactivated. Press “OK” to
save. After 5 seconds without operation, the heater will also automatically
save the setting and return to previous working mode. The default factory
setting is o.
When “on” is selected, the icon “ ” will show on the screen. When
temperature decrease is detected, the appliance will enter anti-freeze mode
(the screen shows 7°C with “ ” flashing). When temperature increase is
detected, it will go back to previous working mode. You can press any button
to return to the previous working mode.
Child lock
Press “M” & “-” for 5 seconds until the screen shows “CC”. The child lock is
now activated. Repeat same operation to deactivate the child lock function.
When child lock is activated, “CC” will flash 3 times and go back to
temperature display. Press any icon on the control panel, the screen will
show “CC” 3 times and go back to temperature display.
13
The child lock function will remain in function after resuming operation after
a power failure.
Display Auto O
Activate: press “-” & “OK” for 5 seconds. The screen will flash 3 times and
activate the Display Auto O function. The display switches o if there is no
operation within 30 seconds. Press any icon to light the display on again.
Deactivate: repeat the same operation to deactivate this function.
When the Display Auto O function is activated, press and hold “OK” & “-”
simultaneously for over 5 seconds, during the process all icons on the display
flash slowly, until all icons on the display go o, the Display Auto O mode
will be deactivated.
Memory function
After power switches o, the heater memorizes the working set
temperature before the power failure and continues to work after power
resumes. In the event of a power failure, the heater will keep the internal
clock running 24 hours. If the power is disconnected for more than 24 hours,
when the power is turned on again, the heater will return to the last used
temperature, the internal clock will return to the default time and start
running again. The screen will flash, indicating that there has been a power
outage. The blinking state will continue until any button is pressed to cancel
the blinking.
Heating icon
1. When it is detected that the ambient temperature is lower than the set
temperature and the heater needs to start working, the heating icon will
light up. If the ambient temperature is detected to be higher than the set
temperature, the heating icon will turn o.
2. In standby state, the heating icon is not displayed.
Reset
Press and hold “+” and “M” at the same time for more than 5 seconds. The
screen will show “rE”. The setting temperature will go back to factory default
setting 19°C.
Wi-Fi connection
Insert the power plug and turn on the power switch. Choose “OF” mode by
pushing the “OK” button until the “OF” symbol is displayed. Keep pressing
“OK” for more than 5 seconds and the icon “ ” will flash.
Refer to the “Wi-Fi guide” for further instructions.
Troubleshooting
If the product does not operate or does not operate properly, first check the
following list. If the reason for the malfunction is not in the following list,
the product may have failed. At this time, it is recommended to send the
product to the dealer or have it repaired.
CLEANING AND STORAGE
It is recommended that the heater be cleaned at least one time during the
operating season in order to provide the optimum level of performance.
ALWAYS TURN THE POWER SWITCH OFF AND UNPLUG THE HEATER
BEFORE CLEANING.
Be sure to save the box for o-season storage.
14
Problem SolutionPossible Cause
The mains plug is
plugged, but the
appliance does not work.
The main plug may not
be correctly inserted into
the mains power socket.
Check whether the plug
is properly inserted into
the mains power socket.
The heater suddenly
stops during heating
The temperature
exceeds the threshold of
the thermal cut- o.
The system will
automatically cut o the
power supply.
Cool the heater down
before using again.
Turn the heater “OFF, unplug it and wait for the heater to cool down.
Use a dry cloth to clean the external surfaces of the heater.
Do not use any cleaning agents or detergents.
Never immerse the heater in water.
Pack the heater in the original carton and store it in a cool and dry place.
Technical data
Frequency range: WiFi 2.4GHz (2.412-2.472GHz), RF Conducted Power:
6.5dBm
15
Ref no. 1926645 1926647 1926649/1926650 1926651/1926652 1930541 1930543
Model
no. POPANW400 POPANW600 POPANW800/
POPANW800B
POPANW1000/
POPANW1000B POLISW800 POLISW1000
Rated
voltage
220-240V~
50-60Hz
220-240V~
50-60Hz
220-240V~
50-60Hz
220-240V~
50-60Hz
220-240V~
50-60Hz
220-240V~
50-60Hz
Rated
power
400W 600W 800W 1000W 800W 1000W
Class II II II II II II
IP
rating IP24 IP24 IP24 IP24 IP24 IP24
16
Model identifier(s): POPANW400
Item Symbol Value Unit UnitItem
Heat output Type of heat input, for electric storage local
space heaters only (select one)
manual heat charge control, with
integrated thermostat
Nominal heat output Pnom 0.4 kW NA
NA
NA
NA
Minimum heat
output (indicative) Pmin -kW
manual heat charge control with room
and/or outdoor temperature feedback
Maximum
continuous heat
output
Pmax,c 0.4 kW
kW
kW
kW
electronic heat charge control with room
and/or outdoor temperature feedback
Auxiliary electricity
consumption fan assisted heat output
single stage heat output and no room
temperature control
Two or more manual stages, no room
temperature control
with mechanic thermostat room
temperature control
with electronic room temperature
control
electronic room temperature control
plus day timer
electronic room temperature control
plus week timer
room temperature control, with
presence detection
room temperature control, with open
window detection
with distance control option
with adaptive start control
with working time limitation
with black bulb sensor
At nominal heat
output elmax 0.000 Type of heat output/room temperature control
(select one)
Other control options (multiple selections
possible)
At minimum heat
output elmin 0.000 No
No
No
No
No
No
No
No
No
In standby mode elSB 0.0005
Yes
Yes
Yes
Contact details Power International AS,
PO Box 523, N-1 471 Lørenskog, Norway
17
Model identifier(s): POPANW600
Item Symbol Value Unit UnitItem
Heat output Type of heat input, for electric storage local
space heaters only (select one)
manual heat charge control, with
integrated thermostat
Nominal heat output Pnom 0.6 kW NA
NA
NA
NA
Minimum heat
output (indicative) Pmin -kW
manual heat charge control with room
and/or outdoor temperature feedback
Maximum
continuous heat
output
Pmax,c 0.6 kW
kW
kW
kW
electronic heat charge control with room
and/or outdoor temperature feedback
Auxiliary electricity
consumption fan assisted heat output
single stage heat output and no room
temperature control
Two or more manual stages, no room
temperature control
with mechanic thermostat room
temperature control
with electronic room temperature
control
electronic room temperature control
plus day timer
electronic room temperature control
plus week timer
room temperature control, with
presence detection
room temperature control, with open
window detection
with distance control option
with adaptive start control
with working time limitation
with black bulb sensor
At nominal heat
output elmax 0.000 Type of heat output/room temperature control
(select one)
Other control options (multiple selections
possible)
At minimum heat
output elmin 0.000 No
No
No
No
No
No
No
No
No
In standby mode elSB 0.0005
Yes
Yes
Yes
Contact details Power International AS,
PO Box 523, N-1 471 Lørenskog, Norway
18
Model identifier(s): POPANW800/POPANW800B
Item Symbol Value Unit UnitItem
Heat output Type of heat input, for electric storage local
space heaters only (select one)
manual heat charge control, with
integrated thermostat
Nominal heat output Pnom 0.8 kW NA
NA
NA
NA
Minimum heat
output (indicative) Pmin -kW
manual heat charge control with room
and/or outdoor temperature feedback
Maximum
continuous heat
output
Pmax,c 0.8 kW
kW
kW
kW
electronic heat charge control with room
and/or outdoor temperature feedback
Auxiliary electricity
consumption fan assisted heat output
single stage heat output and no room
temperature control
Two or more manual stages, no room
temperature control
with mechanic thermostat room
temperature control
with electronic room temperature
control
electronic room temperature control
plus day timer
electronic room temperature control
plus week timer
room temperature control, with
presence detection
room temperature control, with open
window detection
with distance control option
with adaptive start control
with working time limitation
with black bulb sensor
At nominal heat
output elmax 0.000 Type of heat output/room temperature control
(select one)
Other control options (multiple selections
possible)
At minimum heat
output elmin 0.000 No
No
No
No
No
No
No
No
No
In standby mode elSB 0.0005
Yes
Yes
Yes
Contact details Power International AS,
PO Box 523, N-1 471 Lørenskog, Norway
19
Model identifier(s): POPANW1 000/POPANW1 000B
Item Symbol Value Unit UnitItem
Heat output Type of heat input, for electric storage local
space heaters only (select one)
manual heat charge control, with
integrated thermostat
Nominal heat output Pnom 1.0 kW NA
NA
NA
NA
Minimum heat
output (indicative) Pmin -kW
manual heat charge control with room
and/or outdoor temperature feedback
Maximum
continuous heat
output
Pmax,c 1.0 kW
kW
kW
kW
electronic heat charge control with room
and/or outdoor temperature feedback
Auxiliary electricity
consumption fan assisted heat output
single stage heat output and no room
temperature control
Two or more manual stages, no room
temperature control
with mechanic thermostat room
temperature control
with electronic room temperature
control
electronic room temperature control
plus day timer
electronic room temperature control
plus week timer
room temperature control, with
presence detection
room temperature control, with open
window detection
with distance control option
with adaptive start control
with working time limitation
with black bulb sensor
At nominal heat
output elmax 0.000 Type of heat output/room temperature control
(select one)
Other control options (multiple selections
possible)
At minimum heat
output elmin 0.000 No
No
No
No
No
No
No
No
No
In standby mode elSB 0.0005
Yes
Yes
Yes
Contact details Power International AS,
PO Box 523, N-1 471 Lørenskog, Norway
20
Model identifier(s): POLISW800
Item Symbol Value Unit UnitItem
Heat output Type of heat input, for electric storage local
space heaters only (select one)
manual heat charge control, with
integrated thermostat
Nominal heat output Pnom 0.8 kW NA
NA
NA
NA
Minimum heat
output (indicative) Pmin -kW
manual heat charge control with room
and/or outdoor temperature feedback
Maximum
continuous heat
output
Pmax,c 0.8 kW
kW
kW
kW
electronic heat charge control with room
and/or outdoor temperature feedback
Auxiliary electricity
consumption fan assisted heat output
single stage heat output and no room
temperature control
Two or more manual stages, no room
temperature control
with mechanic thermostat room
temperature control
with electronic room temperature
control
electronic room temperature control
plus day timer
electronic room temperature control
plus week timer
room temperature control, with
presence detection
room temperature control, with open
window detection
with distance control option
with adaptive start control
with working time limitation
with black bulb sensor
At nominal heat
output elmax 0.000 Type of heat output/room temperature control
(select one)
Other control options (multiple selections
possible)
At minimum heat
output elmin 0.000 No
No
No
No
No
No
No
No
No
In standby mode elSB 0.0005
Yes
Yes
Yes
Contact details Power International AS,
PO Box 523, N-1 471 Lørenskog, Norway
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

POINT POPANW800B PANELOVN, SVART Bruksanvisning

Typ
Bruksanvisning