Human Care General Purpose Sling Användarmanual

Typ
Användarmanual
User manual/Bruksanvisning/ Manuel de l’ulisateur/
Gebrauchsanweisung
General purpose sling
NSB-103, NSB-104, NSB-105, NSB-109
2www.humancaregroup.com
Content ENGLISH
User Manual 3
Compliances and Standards 4
Safety Instrucons 4
General Descripon 5
Technical Specicaons 5
Product Label 7
Suspension Alternaves 8
Hanger Bars for Human Care Lis 9
Compability 9
Sling Applicaon 10
Care Instrucons 14
Innehåll Svenska
Bruksanvisning 16
Överensstämmelse och standarder 17
Säkerhets instrukoner 18
Allmän beskrivning 19
Tekniska specikaoner 19
Produkteke 20
Upphängningsalternav 21
Lybygel för Human Care Liar 22
Kompabilitet 22
Sling Applikaon 23
Skötselråd 27
www.humancaregroup.com 3
ENGLISH
Symbols
WARNING symbol indicates a poten-
ally hazardous situaon which, if not
avoided, could result in serious injury
to the user or damage to property
and/or the device itself.
INFORMATION symbol indicates
recommendaons and informaon for
proper, trouble-free usage.
WEIGHT CAPACITY symbol indicates
maximum user weight for the product.
Do not exceed this weight in any
circumstance.
CE MARKING symbol indicates product
meets requirements of EU Direcve
93/42/EEC (MDD) and/or EU
Regulaon 2017/745 (MDR).
RECYCLE according to local regulaons.
MEDICAL DEVICE symbol indicates
that the product is a medical device
according to the denion of
medical device in EU Direcve 93/42/
EEC (MDD) and/or EU Regulaon
2017/745 (MDR).
READ INSTRUCTIONS and ensure you
fully understand them before using
this product.
Important!
You must read the user manual for your device prior to usage. Keep this
booklet and informaon handy for future use.
Product modicaon is not per-
mied.
Before use, always check that the
product is not damaged or worn.
Human Care’s products are connuously
being developed and updated to provide our
customers with the highest quality. We reserve
the right to make design changes without prior
noce.
Always make sure that you have the most
recent version of the manual which is available
for downloading from our website at
www.humancaregroup.com.
Contact your local distributor if you have any
quesons about the product and its use.
Noce to user/paent in case of serious
incident
Any serious incident that has occurred in rela-
on to the product, should be reported to the
local contact, who reports to the manufacturer,
and the competent authority of the country in
which the user/paent is established.
User Manual
4www.humancaregroup.com
General Purpose sling
Human Care is an ISO 13485:2016 cered
Swedish medical device company. The Quality
Management System is in compliance with US
21 CFR part 820.
The product is CE marked in accordance with EU
Direcve 93/42/EEC (MDD) and/or EU Regula-
on 2017/745 (MDR), as class I medical device.
The CE mark is on the product.
This product has been tested in accordance
with ISO 10535.
Compliances and Standards
Safety Instrucons
Check that the client is sing securely in the
sling before starng to li him/her.
Check that the li is balanced when moving,
raising and/or lowering the client. If you
are using a Human Care li with telescopic
hanger bar, it is important that the bar hooks
are in the same posion on both sides.
Our slings have been designed and tested
for indoor use with one client at a me and
must only be used for transferring a person.
This product is not a swing.
Make sure no sharp objects are in contact
with the sling.
IncorrectCorrect
The process of liing and moving a person
always involves risks. Therefore, you must read
the user manuals for the li and the liing
equipment carefully. Always make sure that
the liing equipment you are using is intended
for use with the li. As a care provider, you are
responsible for the client’s safety and you must
know whether the client will be able to cope
with the liing process. The sling must be ed
to meet the client’s specic needs. If you are in
any doubt, please contact the supplier.
Carry out a careful visual inspecon of the
sling every me you use it.
Check that the right sling is being used for
the client. The model, size and material must
meet the client’s needs.
Plan the moving and liing process so that it
is as safe as possible.
Before raising the client, check that the sling
is correctly aached to the li/hanger bar
once the li straps are stretched.
It is important that the hooks of the hanger
bar are in the correct posion, with the
opening of the hook facing upwards on both
sides to securely hold the straps in place.
Recheck the posion of the hooks once the
li straps are stretched.
It is important to always check that the loops
are at the boom of all hooks (see pictures)
and securely placed below the locking pin on
all hooks.
www.humancaregroup.com 5
ENGLISH
The General purpose sling is available in reusa-
ble and single paent use versions with loops
and/or clips. This sling allows for easy seated
transfer and has built in exibility to achieve
proper leg and body posioning for paents
with some upper body control.
General Descripon
Technical specicaons
Item Part no. Material Number
of straps
Size A (mm/
inch)
B (mm/
inch)
C (mm/
inch)
Weight
capacity
General purpose sling
single paent use NSB-105-S Polyester 4 straps S775 mm
/ 31”
838 mm
/ 33”
304 mm /
12” 318 kg/ 700 lbs
General purpose sling
single paent use NSB-105-M Polyester 4 straps M972 mm
/ 38”
883 mm
/ 35”
425 mm /
17” 318 kg/ 700 lbs
General purpose sling
single paent use NSB-105-L Polyester 4 straps L1143 mm
/ 45”
1029 mm
/ 41”
533 mm /
21” 318 kg/ 700 lbs
General purpose sling
single paent use NSB-105-XL Polyester 4 straps XL 1334 mm
/ 53”
1143 mm
/ 45”
679 mm /
27” 318 kg/ 700 lbs
General purpose sling
reusable NSB-103-S* Polyester net 8 straps S775 mm
/ 31”
838 mm
/ 33”
304 mm /
12” 318 kg/ 700 lbs
General purpose sling
reusable NSB-103-M* Polyester net 8 straps M972 mm
/ 38”
883 mm
/ 35”
425 mm /
17” 318 kg/ 700 lbs
General purpose sling
reusable NSB-103-L* Polyester net 8 straps L1143 mm
/ 45”
1029 mm
/ 41”
533 mm /
21” 318 kg/ 700 lbs
General purpose sling
reusable NSB-103-XL* Polyester net 8 straps XL 1334 mm
/ 53”
1143 mm
/ 45”
679 mm /
27” 318 kg/ 700 lbs
General purpose sling
reusable bariatric NSB-109-2XPH* Polyester net 8 straps Bariatric 775 mm
/ 31”
838 mm
/ 33”
304 mm /
12” 454 kg/ 1000 lbs
General purpose sling
single paent use NSB-104-S polymethylpentene 8 straps S775 mm
/ 31”
838 mm
/ 33”
304 mm /
12” 318 kg/ 700 lbs
General purpose sling
single paent use NSB-104-M polymethylpentene 8 straps M972 mm
/ 38”
883 mm
/ 35”
425 mm /
17” 318 kg/ 700 lbs
General purpose sling
single paent use NSB-104-L polymethylpentene 8 straps L1143 mm
/ 45”
1029 mm
/ 41”
533 mm /
21” 318 kg/ 700 lbs
General purpose sling
single paent use NSB-104-XL polymethylpentene 8 straps XL 1334 mm
/ 53”
1143 mm
/ 45”
679 mm /
27” 318 kg/ 700 lbs
The illustraon shows the
NSB-104C and NSB-103C
The illustraon shows the
NSB-105
Technical Specicaons
It is crucial to use the right size of sling for the
client. To help dierenate our sizes, they are
colour coded for quick idencaon. The colour
code is found next to the sling’s label in the
shape of a loop. This loop can also be used to
properly store or hang the sling.
C
B
A
6www.humancaregroup.com
General Purpose sling
* Only distributed in USA
General purpose sling
single paent use with clips NSB-104C-S polymethylpentene 4 straps S775 mm
/ 31”
838 mm
/ 33”
304 mm /
12” 318 kg/ 700 lbs
General purpose sling
single paent use with clips NSB-104C-M polymethylpentene 4 straps M972 mm
/ 38”
883 mm
/ 35”
425 mm /
17” 318 kg/ 700 lbs
General purpose sling
single paent use with clips NSB-104C-L polymethylpentene 4 straps L1143 mm
/ 45”
1029 mm
/ 41”
533 mm /
21” 318 kg/ 700 lbs
General purpose sling
single paent use with clips NSB-104C-XL polymethylpentene 4 straps XL 1334 mm
/ 53”
1143 mm
/ 45”
679 mm /
27” 318 kg/ 700 lbs
General purpose sling
reusable with clips NSB-103C-S Polyester/coon 4 straps S775 mm
/ 31”
838 mm
/ 33”
304 mm /
12” 318 kg/ 700 lbs
General purpose sling
reusable with clips NSB-103C-M Polyester/coon 4 straps M972 mm
/ 38”
883 mm
/ 35”
425 mm /
17” 318 kg/ 700 lbs
General purpose sling
reusable with clips NSB-103C-L Polyester/coon 4 straps L1143 mm
/ 45”
1029 mm
/ 41”
533 mm /
21” 318 kg/ 700 lbs
General purpose sling
reusable with clips NSB-103C-XL Polyester/coon 4 straps XL 1334 mm
/ 53”
1143 mm
/ 45”
679 mm /
27” 318 kg/ 700 lbs
www.humancaregroup.com 7
ENGLISH
Product Label
The label on the sling contains the following
informaon:
1. Human Care company logo
2. This way up arrow and marking the centre
line of the sling
3. CE and MD marking
4. Product name and size
5. Picture showing the sling in use
6. Part number
7. Safe Working Load
8. This side facing out” – outside of the
sling, not in touch with the client
9. Manufacturer
10. Date and country of producon
11. Instrucon labels
a. Do not use fabric soener
b. Visual inspecon
c. Latex Free
d. Read the manual before use
12. Serial number
13. Washing instrucons
a. Machine Wash Temperature
b. Do Not Bleach
c. Tumble Dry, Low Heat
d. Do Not Dry Clean
e. Never Iron
14. Owner name. (For example, write the
client’s name or another unique idener)
15. Indicate bi-annual inspecon
16. UDI: (01) EAN/GS1/GTIN (11) manu-
facturing date (21) serial number
17. Unique Product Code
18. QR code to user manual
REF
NSB-103C-M
SWL < 318kg / < 701lbs
Human Care HC AB
Årstaängsvägen 21B
117 43 Stockholm
Sweden
http://www.humancaregroup.com
General Purpose Sling
w clips, Medium
UP
This side facing out
SN
#
75°C/167°F
*334118030048*
Due date next periodic inspection (every 6 months), mark:
2023-03-06
LV
881608 900028
UPC
(01) 0 7331599 44172 5 (11) 230306 (21) 334118030048
UDI
1 2
5
6
3
4
7
8
9
12
11
10
13
14
15
16
17
20
a
a
a
a
a
a
a
a
a
c
b
e
d
a
a
a
a
a
a
a
a
a
c
b
d
18
8www.humancaregroup.com
General Purpose sling
Suspension Alternaves
Our slings are designed with the premise that
all people are dierent with varying liing
requirements, needs or desires.
To make all our clients feel as comfortable as
possible in our slings, most of them can be used
with 2 or 3-point suspensions. Some slings can
also be used with a 4-point suspension. Below
the opons are displayed.
2-point suspension
Suitable for most liing situaons providing a good
seang posion. 2-point suspension is available with
oor lis, xed and portable ceiling lis.
Two-point suspension with crossed leg support:
Thread the strap on one leg secon through the strap
on the other leg secon before aaching them to the
hanger bar.
An individual assessment of the client’s needs
must always be carried out before choosing an
alternave connecon method.
3-point suspension
Oers an elongated sing posion and more even
weight distribuon. The 3-point suspension is suitable
especially for clients carrying an increased risk of
pressure sores or who need addional space for the
upper body.
Thread the le leg secon through the loop on the
right leg secon. Aach the leg secon liing straps
to the leg hooks and the back secon liing straps to
the li.
4-point suspension
A spacious sing posion making it suitable for larger
clients or when using a stretcher. 4-point suspension
is available with both xed and portable ceiling lis
or oor lis.
www.humancaregroup.com 9
ENGLISH
Hanger Bars for Human Care Lis
Accessory Descripon Part no.
2-point hanger bar For staonary li HeliQ. 3 widths: 35 cm/13,8”: 72754
45 cm/17,7”: 72755
60 cm/23,6”: 72757
2-point hanger bar For portable lis Roomer S / Altair,
2 widths:
45 cm/17,7”: 55751
55 cm/21,7”: 55764
4-point hanger bar For staonary li HeliQ 92938
4-point suspension 4-point suspension accessory (49 cm). Enables 4-point liing with the Altair and Roomer S
lis. The suspension bar is placed on the li’s single leg hook.
55619
Compability
Human Care Group slings are designed for use
with all Human Care lis and hanger bars. The
products are also compable with products of
other suppliers ulizing the same aachment
method for securing slings to a hanger bar and
li. However, due to the wide range of products
worldwide, Human Care cannot be responsible
for any errors that may result from improper
use or applicaon of combinaons of slings,
hanger bars and lis of other suppliers. The use
of the combined system is at the prescribers
own risk and liability.
To ensure the safety of the client and caregiver,
Human Care recommends the following mini-
mum requirements:
1. When using slings with lis and hang-
er bars, made by manufacturers other
than Human Care, the combined system
needs to be designed with the same sling
aachment method for the hanger bar of
oor lis and ceiling lis, meaning loop
style slings are combined with a loop style
hanger bar, clip style slings are combined
with a clip style hanger bar.
2. The involved paent lis and sling must be
CE marked in accordance with the medical
device direcve, MDD 93/42/
EEG / upcoming MDR 2017/75 and comply
with standard requirements for paent lis
as stated in EN ISO 10535.
3. The caregiver must follow the manufactu-
rers instrucon manuals and recommen-
daons with respect to the use, care,
client, caregiver, cleaning, and inspecon
of the slings and lis.
4. Dierent products on the assembled li
system: i.e., li, hanger bar, sling, scale and
other accessories may have dierent max.
loads. It is always the lowest maximum
allowable load indicated for the respecve
products and the system that applies for
the enre system.
Always check the markings on all individual
products in the system.
5. Individual risk assessment, including a
praccal test of the system and validaon
with the specic combinaon used are
required to arm that the size of the sling
is correct for the intended use and compa-
ble to the width and design of the hanger
bar. The combined system needs to be
documented by the competent assessor.
If there are any quesons, please contact your
local Human Care oce or distributor.
10 www.humancaregroup.com
General Purpose sling
Sling Applicaon
Applying the sling from a seated posion
(NSB-103 used as reference)
1. Stand behind or to the side of the paent
and hold the sling with label facing up and
away. Work the sling down the back, the
boom edge should be placed behind the
paent´s coccyx.
2. Pull the leg secons through to the front.
Raise each leg and pull the leg secons
under paent´s legs.
3. Lower the hanger bar and securely aach
straps (please see page 2). There are die-
rent ways to aach the loops to a hanger bar
and to posion the legs. This sling can be used
both with 2-, 3- or 4-point hanger bars. The
image above shows aachment to a 4-point
hanger bar with legs in a divided posion.
Please see chapter “posioning the legs”
to the right for the dierent opons when
using a 4-point hanger bar. For aachment
of this sling to a 2-point or a 4-point hanger
bar, please see chapter “aaching sling to
hanger bars” to the right.
4. Connue liing the paent. It is a good idea
to put your arm around the paent while
you are moving him/her to create a greater
sense of security.
www.humancaregroup.com 11
ENGLISH
Applying the sling from a lying posion
(NSB-103 used as reference)
Posioning the body
1. Stand to side and turn the paent to face
you. Place gathered sling behind back with
label facing up and away.
2. Turn the paent on back and pull gathered
sling towards you.
3. Bring the leg secons underneath the thighs
to achieve the desired posioning of the
legs.
4. Lower the hanger bar and securely aach
straps (see page 2) with appropriate loop.
For sling with clips: Aach the leg
secon liing clips to the liing frame.
Turn the li around and aach the back
secon liing clips to the li frame.
To achieve the upright posion, use the short
loops of the head and shoulders and the long
loops of leg straps.
To achieve the reclined posion, use the middle
or long loops of the head and shoulders straps
and the middle or short loops of leg straps.
12 www.humancaregroup.com
General Purpose sling
Posioning the legs (4-point hanger bar)
To achieve the open posion, bring the leg
secons up between the thighs and aach the
leg straps to the hanger bar.
To achieve the divided posion, bring the leg
secons up between the thighs, thread one leg
strap through the boom opening of other (le)
and aach the leg straps to the hanger bar cross
over style.
For a more relaxed posion, aached to the
center hook of the hanger bar.
To achieve the closed posion, pull one leg
band than the other underneath both thighs
and aach to the hanger bar.
www.humancaregroup.com 13
ENGLISH
Aaching the General purpose sling to hanger bars
2-point hanger bar 3-point hanger bar 4-point hanger bar
Sling with 8 straps:
Starng from head, the 3 top
straps on the le aached on le
side, repeat on the right side. The
2 leg straps should be aached to
the hook on each side.
Sling with 8 straps:
Starng from head, the 3 top
straps on the le - aach on
le side, repeat on right side,
the 2 leg straps (right and le) -
aach to the leg hook.
Sling with 8 straps:
Each hook should have 2 straps
aached. The
boom 2 leg straps can be cros-
sed for increased comfort.
Sling with 4 straps:
Starng from head, the 1 top
strap on the le aach on le
side, repeat on right side(1), The
2 leg straps should be aached to
the hook on each side.
Sling with 4 straps:
Starng from head, the 1 top
strap on the le - aach on le
side, repeat on right side(1).
The 2 leg straps (right and le)
aach to leg hook.
Sling with 4 straps:
Each hook should have 1 straps
aached. The
boom 2 leg straps can be cros-
sed for increased comfort.
Care Instrucons
Check for wear and tear
Check the sling for wear and tear. It is important
to check the fabric, the edging, the seams and
the liing straps.
Damaged liing equipment must not be used.
Cleaning
Human Care slings are intended for individual
use. To avoid infecons or transmission of bac-
teria, it is important to clean the slings properly.
All slings should be machine washed and dried
as soon as possible. Slings should always be
cleaned aer use in a wet situaon.
Single Paent Use (SPU) slings can not be was-
hed, they should be discarded.
Always refer to the label of the sling
before washing.
Periodic inspecon
A periodic inspecon must be carried out at
least every 6 months. See Human Care’s peri-
odic inspecon log which can be found on our
website at www.humancaregroup.com
Product lifeme
The product´s expected lifeme 3 years or
150-180 mes washing, if the product is used
as intended and maintained according to the
manufacturer´s instrucons, depending on the
intensity of use and maximum load applied
during use. If the product label is no longer
legible, the product should be discarded.
Warranty and support
If you need informaon or support, please
contact your Human Care oce,
www.humancaregroup.com, or distributor.
Recycling
Once the product has reached the end of its life,
it should be disposed according to your coun-
trys rules, especially for the separate collecon
of electrical and electronic products.
Correct disposal helps prevent negave
consequences for the environment and human
health.
14 www.humancaregroup.com
General Purpose sling
Approved Disinfectants Soluons to Avoid
Chemical Disinfecon: 70% Ethanol, 45% isopropanol or similar Steam sterilizaon
Thermal Disinfecon: Wash 65°C (149°F) for a minimum of 10 minutes1Iodine based disinfectants
Thermal Disinfecon: Wash 71°C (160°F) for a minimum of 3 minutes1Gas sterilizaon
Note: Add 8 minutes to both thermal disinfecon opons to ensure heat has penetrated the fabric.
Finish with a rinse cycle.1
1 Ref: HSG (95) 18: Hospital Laundry Arrangements for Used and Infected Linen, Department of Health, NHS (Naonal Health Service, England)
Disinfecon Procedure
Human Care slings are intended to be used with
one paent at a me. To avoid possible trans-
mission of infecous diseases, it is important to
clean the sling if it has become soiled or if it is to
be used by a dierent paent.
Overview of Sling Material Care
Polyester
Polyester Net
Trevira So Air Mesh
Polyester/Polyester Net
Polyester/Coon
Venlated Polyester
Coon
Polyester Tricot
Coated Nylon
jMachine Wash Maximum Temperature 60°C (140°F) (slings with padding)
bMachine Wash Maximum Temperature 75°C (167°F)
TTumble Dry Low, Maximum Temperature 30°C - 54°C (86°F - 130°F)
VTumble Dry Low, Maximum Temperature 60°C (140°F )
UDo Not Tumble Dry
CDo Not Iron
KDo Not Dry Clean
HDo Not Bleach
Do Not Use Fabric Soener
dDo Not Wash
Dispose of Aer Use
Disinfecon Permied (see list of approved disinfectants)
www.humancaregroup.com 15
ENGLISH
16 www.humancaregroup.com
General Purpose Sling
Bruksanvisning
Symbols
VARNING symbolen indikerar en
potenellt farlig situaon som, om
den inte undviks, kan leda ll allvarlig
personskada eller skada på egendom
och / eller själva enheten.
INFORMATIONS symbolen anger
rekommendaoner och informaon
för korrekt och problemfri användning.
VIKTKAPACITET symbolen indikerar
maximal användarvikt för produkten.
Överskrid inte denna vikt under några
omständigheter.
CE MARKING symbolen indikerar a
produkten uppfyller kraven i EUs direk-
v 93/42/EEC och/eller EUs förordning
2017/745.
ÅTERVINNING enligt lokala föreskrier.
LÄS INSTRUKTIONER och se ll a du
förstår dem innan du använder den
här produkten.
Vikgt!
Du måste läsa bruksanvisningen för din enhet innan du använder den. Håll
denna broschyr och informaon ll hands för framda användning.
Anpassningar av produkten är
inte llåtet.
Kontrollera alld a produkten
inte är skadad eller sliten innan
den används.
Human Cares produkter utvecklas och uppda-
teras konnuerligt för a våra kunder ska få
bästa kvalitet. Vi förbehåller oss räen a göra
förändringar av produkten utan a informera
om dea i förväg.
Säkerställ a du alld har den senaste versionen
av bruksanvisningen, vilken nns llgänglig för
nedladdning på vår hemsida,
www.humancaregroup.com.
Kontakta din återförsäljare om du har frågor
rörande produkten eller hur den ska användas.
Meddelande ll användare / paent vid
allvarlig händelse
Alla allvarliga incidenter som inträar vid an-
vändande av produkten, ska rapporteras ll den
lokala kontakten, som rapporterar ll llverka-
ren, och den behöriga myndigheten i det land
där användaren/paenten är bosa.
MEDICAL DEVICE symbolen indikerar
a produkten är medicinsk utrust-
ning enligt denionen av medicinsk
utrustning i EUs direkv 93/42/EEC
(MDD) och / eller EU-förordningen
2017/745 (MDR).
www.humancaregroup.com 17
SVENSKA
Säkerhetsinstrukoner
Kontrollera a vårdtagaren sier säkert i
selen innan lyet.
Kontrollera a lyen är i balans när vård-
tagaren föryas, höjs eller sänks. Om du
använder en Human Care ly med teleskop-
bygel, är det vikgt a bygelkrokarna är i
samma posion på båda sidor.
FelRä
Ly och föryning av en person medför alld
en risk. Läs därför noga igenom bruksanvisning
för både ly och lyllbehör. Förvissa dig alld
om a de lyllbehör du använder fungerar
ihop med lyen. Som vårdgivare är du ansvarig
för vårdtagarens säkerhet och du måste känna
ll dennes möjlighet a klara lysituaonen.
Lyselen skall vara anpassad och utprovad för
vårdtagarens särskilda behov. Vid tveksamheter
kontakta leverantören.
Genomför en noggrann visuell inspekon av
selen varje gång du använder den.
Kontrollera a rä sele används ll vårdta-
garen. Modell, storlek och material skall vara
anpassade ll vårdtagarens behov.
Planera föryningen/lyet så a det sker
så säkert som möjligt.
Kontrollera a selen är korrekt kopplad ll
lyen när banden är sträckta, men innan
vårdtagaren har lämnat underlaget.
Det är vikgt a bygelns krokar har rä
posion, med öppningen på krokarna vänd
uppåt på båda sidor för a selöglorna ska sit-
ta säkert på plats. Kontrollera åter krokarnas
posion när banden sträckts.
Det är vikgt a alld kontrollera a selög-
lorna är placerade i boen av alla krokar
(se bild nedan) och säkert placerade under
urkrokningsskyddet på alla krokar.
Överensstämmelse och standard
Human Care är e svenskt ISO 13485:2016-cer-
erat medicintekniskt företag. Kvalitetsstyr-
ningssystemet uppfyller US 21 CFR del 820.
Denna sele har testats i överensstämmelse med
ISO 10535.
Lyselen är CE-märkt enligt EU direkv 93/42/
EEC (MDD) och/eller EU förordning 2017/745
(MDR), som klass 1 medicinteknisk produkt.
CE-märknigen nns på selen.
18 www.humancaregroup.com
General Purpose Sling
Allmän beskrivning/Avsedd användning
General Purpose sling
General Purpose selen nns i återanvändbara
och engångsversioner med öglor och/eller klipp.
Denna sele möjliggör enkel föryning siande
och har inbyggd exibilitet för a uppnå korrekt
ben- och kroppsposionering för paenter
med viss överkroppskontroll. Gjord för kraigt
övervikga personer.
Tekniska specikaoner
Det är avgörande a använda en för
vårdtagaren lämplig storlek på sele. För
a underläa a skilja emellan våra
storlekar har selarna färgkoder. Färgko-
derna hias inll selens eke i form av
en ögla. Öglan kan också användas för
lämplig förvaring eller upphängning av
selen. Illustraonen visar
NSB-105
Tekniska specikaoner
Arkel Arkelnummer Material Antal
öglor
Storlek A (mm) B (mm) C (mm) Maximal
brukarvikt (kg)
General purpose sling
single paent use NSB-105-S Polyester 4 öglor S 775 mm 838 mm 304 mm 318 kg
General purpose sling
single paent use NSB-105-M Polyester 4 öglor M 972 mm 883 mm 425 mm 318 kg
General purpose sling
single paent use NSB-105-L Polyester 4 öglor L 1143 mm 1029 mm 533 mm 318 kg
General purpose sling
single paent use NSB-105-XL Polyester 4 öglor XL 1334 mm 1143 mm 679 mm 318 kg
General purpose sling
återanvändbar NSB-103-S* Polyester nät 8 öglor S 775 mm 838 mm 304 mm 318 kg
General purpose sling
återanvändbar NSB-103-M* Polyester nät 8 öglor M 972 mm 883 mm 425 mm 318 kg
General purpose sling
återanvändbar NSB-103-L* Polyester nät 8 öglor L 1143 mm 1029 mm 533 mm 318 kg
General purpose sling
återanvändbar NSB-103-XL* Polyester nät 8 öglor XL 1334 mm 1143 mm 679 mm 318 kg
General purpose sling
återanvändbar bariatrisk NSB-109-2XPH* Polyester nät 8 öglor Bariatric 775 mm 838 mm 304 mm 454 kg
General purpose sling
single paent use NSB-104-S polymethylpentene 8 öglor S 775 mm 838 mm 304 mm 318 kg
General purpose sling
single paent use NSB-104-M polymethylpentene 8 öglor M 972 mm 883 mm 425 mm 318 kg
General purpose sling
single paent use NSB-104-L polymethylpentene 8 öglor L 1143 mm 1029 mm 533 mm 318 kg
General purpose sling
single paent use NSB-104-XL polymethylpentene 8 öglor XL 1334 mm 1143 mm 679 mm 318 kg
C
B
A
www.humancaregroup.com 19
SVENSKA
General purpose sling
single paent use med clips NSB-104C-S polymethylpentene 4 öglor S 775 mm 838 mm 304 mm 318 kg
General purpose sling
single paent use med clips NSB-104C-M polymethylpentene 4 öglor M 972 mm 883 mm 425 mm 318 kg
General purpose sling
single paent use med clips NSB-104C-L polymethylpentene 4 öglor L 1143 mm 1029 mm 533 mm 318 kg
General purpose sling
single paent use med clips NSB-104C-XL polymethylpentene 4 öglor XL 1334 mm 1143 mm 679 mm 318 kg
General purpose sling
återanvändbar med clips NSB-103C-S Polyester/bomull 4 öglor S 775 mm 838 mm 304 mm 318 kg
General purpose sling
återanvändbar med clips NSB-103C-M Polyester/bomull 4 öglor M 972 mm 883 mm 425 mm 318 kg
General purpose sling
återanvändbar med clips NSB-103C-L Polyester/bomull 4 öglor L 1143 mm 1029 mm 533 mm 318 kg
General purpose sling
återanvändbar med clips NSB-103C-XL Polyester/bomull 4 öglor XL 1334 mm 1143 mm 679 mm 318 kg
20 www.humancaregroup.com
General Purpose Sling
Produkteke
Ekeen på selen innehåller följande informaon:
1. Human Cares företagslogotyp
2. Denna sida upp-pil, markerar även mien
3. CE- och MD-märkning
4. Produktnamn och storlek
5. Bild som visar selen i bruk
6. Arkelnummer
7. Säker arbetslast
8. This side facing out”(Denna sida ut) se-
lens utsida; ej i kontakt med vårdtagaren
9. Tillverkare
10. Tillverkningsdatum och -land
11. Instrukonsekeer
a. Ej sköljmedel
b. Okulärbesikning
c. Latexfri
d. Läs manual innan användning
12. Serienummer
13. Tvänistrukoner
a. Maskintvästemperatur
b. Ej blekmedel
c. Torktumling; låg temperatur
d. Ej kemtvä
e. Ej strykning
14. Ägarens namn (Märk t.ex. med
vårdtagarens namn eller en annan unik
idenering)
15. Ange halvårlig inspekon
16. UDI: (01) EAN/GS1/GTIN (11) produkons-
datum (21) serienummer
17. Unik produktkod
18. QR kod ll bruksanvisning
REF
NSB-103C-M
SWL < 318kg / < 701lbs
Human Care HC AB
Årstaängsvägen 21B
117 43 Stockholm
Sweden
http://www.humancaregroup.com
General Purpose Sling
w clips, Medium
UP
This side facing out
SN
#
75°C/167°F
*334118030048*
Due date next periodic inspection (every 6 months), mark:
2023-03-06
LV
881608 900028
UPC
(01) 0 7331599 44172 5 (11) 230306 (21) 334118030048
UDI
1 2
5
6
3
4
7
8
9
12
11
10
13
14
15
16
17
20
a
a
a
a
a
a
a
a
a
c
b
e
d
a
a
a
a
a
a
a
a
a
c
b
d
18
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Human Care General Purpose Sling Användarmanual

Typ
Användarmanual