User manual
MAINTENANCE
SAFETY VALVE
The safety valve (FL1) must be inspected regularly, about 4
times a year, to prevent clogging. Check by turning the
safety valve’s knob anticlockwise, water should then flow
through the overflow pipe. If this doesn’t happen, the safety
valve is defective and must be replaced.
The safety valve sometimes releases a little water after hot
water has been used. This discharge is caused by the expan-
sion of cold water entering the water heater, resulting in a
pressure increase, whereby the safety valve opens.
EMPTYING
1. Turn off the power to the water heater.
2. Shut off the cold water inlet with valve QM35).
3. Loosen the cover of the drain valve (QM3) and install
the supplied hose connector and hose.
4. Turn the drain valve (QM3).
5. During draining, air must be let into the water heater by
loosening the hot water heater connection (XL4) or
opening a hot water tap. In order to ensure the complete
emptying of the water heater, the hose connection must
be completely tight and the outlet must be below the
lowest point of the water heater.
NOTE
The hose must exit below the water heater’s lowest
level.
Water splashes may occur at the overflow pipe.
There is a risk of scalding.
When installed in a location that is exposed to the risk of
frost, the water heater must be emptied whenever it is not
in operation. Freezing will result in the water heater bursting.
DEALING WITH MALFUNCTIONS
NOTE
Electrical installation and service must be carried
out under the supervision of a qualified electrician,
and in accordance with applicable electrical safety
regulations.
Check the installation's fuses as well as the thermostat and
mixer valve settings.
Wait a few hours without hot water usage and then check
whether the temperature level has risen. If there is still no
hot water, contact the installation engineer.
SERVICE
For service, contact the installer. The serial number (PF3)
(14 digits) and installation date should always be stated.
Only electrical equipment supplied by NIBE AB in Markaryd
may be used.
Installer manual
GENERAL
ES 160, ES 210, ES 300 is a series of water heaters that are
suitable for installation in, for example, boiler rooms.
DESIGN
ES 160, ES 210, ES 300 consists of a steel vessel, with a
copper lining to protect against corrosion. The outer casing
is made of robust plastic. The water heater is insulated with
a freon-free polyurethane foam, which provides good
thermal insulation.
ES 300 have a connection for hot water circulation.
The water heater is designed and manufactured for a max-
imum cut-off pressure of 10 bar.
TRANSPORT
ES 160, ES 210, ES 300 should be transported and stored
vertically in a dry place.
However, the ES 160, ES 210, ES 300 can be carefully laid
on its back when being moved into a building.
ASSEMBLY
The water heater is only designed for upright installation.
The water heater is unscrewed from the pallet and lifted into
position.
Position ES 160, ES 210, ES 300 on a firm base that can take
the weight, preferably on a concrete floor or foundation.
Use the product's adjustable feet to obtain a horizontal and
stable set-up.
The area where the ES 160, ES 210, ES 300 is located must
be frost-proof and equipped with a floor drain.
30 - 50 mm
30 - 50 mm
15 - 40 mm