SENZ SEDH3010 AVFUKTER Bruksanvisning

Typ
Bruksanvisning
1
EVERYDAY PERFORMANCE
Dehumidifier
SEDH3010
User Manual
2
Thank you for purchasing your new SENZ dehumidifier. These
operating instructions will help you use it properly and safely. We
recommend that you spend some time reading this instruction
manual in order that you fully understand all the operational
features it offers. Read all the safety instructions carefully before
use and keep this instruction manual for future reference.
Takk for at du kjøpte din nye avfukter fra SENZ. Denne
bruksanvisningen vil hjelpe deg med å bruke den på en trygg og
riktig måte. Vi anbefaler at du tar deg tid til å lese gjennom hele
bruksanvisningen for å bli fortrolig med alle funksjonene som tilbys.
Les alle sikkerhetsanvisningene nøye før bruk, og oppbevar
bruksanvisningen for fremtidig referanse.
Kiitos, kun valitsit uuden SENZ-ilmankuivaimen. Nämä käyttöohjeet
opastavat sinua käyttämään laitetta oikein ja turvallisesti. On
suositeltavaa käyttää aikaa tämän käyttöoppaan lukemiseen, jotta
ymmärrät täysin, mitä toiminnallisia ominaisuuksia tuote tarjoaa.
Lue kaikki turvallisuusohjeet huolellisesti ennen laitteen käyttöä ja
säilytä käyttöopas myöhempää käyttöä varten.
Tak for købet af din nye affugter fra SENZ. Disse brugervejledninger
hjælper dig med at bruge dette apparat rigtigt og sikkert. Vi
anbefaler, at du læser denne brugervejledning, så du får en fuld
forståelse af hvordan alle funktionerne virker. Læs
sikkerhedsforskrifterne grundigt inden brug, og gem denne
brugervejledning til senere brug.
Tack för att du har köpt en avfuktare från SENZ. Denna
bruksanvisning hjälper dig att använda den på ett säkert och korrekt
sätt. Vi rekommenderar att du tar dig tid att läsa igenom denna
bruksanvisning för att till fullo förstå alla driftfunktioner som den
erbjuder. Läs noga igenom alla säkerhetsinstruktioner före
användning och spara bruksanvisningen för framtida bruk.
3
User Manual – English ……………….. page 4 - 24
Brukermanual – Norsk ……………….. side 25 - 44
Käyttöohje – Suomi ……………….. sivu 45 - 66
Brugermanual – Dansk ……………….. side 67 - 87
Användarhandbok – Svenska ……………….. sida 88 - 109
GB
SE DK NOFI
4
I.SAFETY WARNINGS
When using the appliance, please observe the following safety
precautions:
1.Unplug the mains power cable before cleaning or storage.
2.The appliance can be used indoors but not in laundry rooms.
3.Do not set the appliance close to heat-generating devices or near
flammable and dangerous materials.
4.Never put your fingers or objects into the intake or discharge
ducts.
5.Do not sit or stand on the appliance.
6.Discard water that has collected in the tank as required.
7.Do not operate the appliance in a closed area such as inside a
closet, as it may cause a fire.
8.Do not use the appliance near edible items, objects of art, or
scientific materials.
9.Install drain piping at a downhill angle to make sure the condensed
water can be drained continuously.
10.If the mains power cable is damaged it must be replaced by the
manufacture or a similarly qualified person in order to avoid a
hazard.
11.The appliance mustbe positioned so that the plug is accessible.
12.Always keep a distance of 20 cm around the appliance and the
wall or other objects to ensure air circulation.
13.The appliance must be installed in accordance with local national
wire regulations.
14.The appliance can not be used in public transportation.
15.This appliance can be used by children aged from 8 years and abo
ve and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the
hazardsinvolved. Children must
not play with the appliance. Cleaning and user
maintenance must not be made bychildren without supervision.
16.Children should be supervised to ensure that theydo not play
with the appliance.
17.Appliances that areobviously damaged must not be operated.
5
A: WARNING:
Do not use means to accelerate the defrosting process or to clean,
other than those recommended by the manufacturer.
The appliance should be stored in a room without continuously
operating ignition sources (for example: open flames, an operating
gas appliance or an operating electric heater).
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
The appliance should be installed, operated and stored in a room
with a floor area larger than 4 m2.
The appliance must be compliant with national gas regulations.
Servicing must be performed only as recommended by the
manufacturer.
The appliance should be stored so as to prevent mechanical damage
from occurring.
Any person who is involved withworking on or breaking into a
refrigerant circuit should hold a current valid certificate from an
industry-accredited assessment authority, which authorizes their
competence to handle refrigerants safely in accordance with an
industry recognized assessment specification.
Servicing must only be performed as recommended by the
equipment manufacturer. Maintenance and repair requiring the
assistance of other skilled personnel must be carried out under the
supervision of the person competent in the use of flammable
refrigerants.
Appliance is filled with flammable gas R290.
Any repairs you need, contact the nearest authorized Service Centre
and strictly follow manufacturer’s instruction only.
6
B: Warning for disposal:
It is prohibited to dispose of this appliance in domestic household
waste. For disposal there are several possibilities:
1.Do not dispose this appliance as unsorted municipal waste.
Collection of such waste separately for special treatment is
necessary.
2.The municipality has established collection systems, where
electronic waste can be disposed of free of charge to the user.
T
his symbol on the product or in the instructions means
t
hat your electrical and electronic equipment should be
d
isposed at the end of its life separately from your
h
ousehold waste. There are separate collection systems
f
or recycling in the EU. For more information, please
c
ontact the local authority or your retailer where you
p
urchased the product.
C: Technical Data
SPECIFICATIONS
Model SEDH3010
Power Supply 220V-240V50Hz
Water Tank Capacity
2L
Refrigerant/charge R290/45g
The dehumidification capacity is rated at a room temperature of
30with a relative humidity of 80%.
If the appliance specification is improved this will be shown on the
appliances rating label.
The operational temperature is in the range of 7to 35and
with a max relative humidity of 80%. If the room temperature is
outside of this range, the appliance will not operate normally. GWP
value of R290 refrigerant is 3.
7
II.FEATURES
Powerful Dehumidifying Capability
Taking advantage of refrigeration technology, the dehumidifier
powerfully removes moisture from the air to decrease the humidity
level of the room and keep the indoor air dry and comfortable.
Lightweight Portable Design
The dehumidifier is built to be compact and lightweight. The casters
on the bottom of the dehumidifier make it easy to move from room
to room.
Low Temperature Operation with Automatic Defrost
When the dehumidifier is running in a room with the temperature
between 5and 12℃, it will be stop to defrost every 30 minutes.
When the appliance is running in a room with the temperature
between 12and 20, it will be stop to defrost every 45 minutes.
Adjustable Humidistat
Adjust to your desired humidity level using the humidistat.
Timer On / Off
Program the dehumidifier to turn on and off automatically.
Quiet Operation
The dehumidifier operates with a low noise level.
Energy Efficient
The power consumption of the dehumidifier is low.
8
III.PRODUCT OVERVIEW
1.Outlet 2. Handle 3. Control panel
4. Filter frame 5. Air intake grid 6. Water tank
7. Wheels (4 x) 8. Mains power cable with plug
OPTIONAL
1.Activated carbon filter clothOptional2. PU filter layerOptional
1
2
9
OPERATING INSTRUCTIONS
LED INDICATORS
1. W.F-LED Red Water Full-Led
2. POWER-LED Green Power Led
3. SET-LED Green Set-Led
4. TIM-LED Green Timer-Led
5. LF-LED Green Low-fan Led
6. HF-LED Green High-fan Led
Humidity Level & Timer 2-digit display
The indicator features 3 functions:
1.When the appliance is plugged in, it will indicate the rooms
humidity level.
2.When yousetthe humidity, it will indicate the humidity level that
you have selected.
3.When you program the time for the appliance to turn on and off, it
will show the hours.
4.When the environment humidity is lower than 35%, it will show
“35”.
5.When the environment humidity is higher than 95%, it will show
“95”.
10
Push Button Functions
A. Power On / Off Push Button
B. Adjustable Humidity Push Button
C. Timer Push Button
D. Fan Speed Push Button
OPERATING INSTRUCTIONS
1.The power indication light will illuminate green when the
appliance is plugged in, regardless of whether the appliance is
operating or not.
2.Press the button onceto start operation. Press it again to
stop operation.
3.press the button to set the desired fan speed. It can be
adjusted between high speed and low speed.
4.Press button to set the desired humidity level in the room,
which can be setfrom 40% to80% at 5% intervals.
5.After a period of working, when humidity level is lower than the
selected humidity by 2%, the compressor will stop and the fan will
stop working 3 minutes later. When the humidity level is equal to or
higher than the selected humidity by 2%, the compressor will
restart once the 3-minute compressor protection time is over.
6.press to program the time when the appliance turns on and
turns off. If you want to cancel the timer programming, press the
button to adjust the time from 0-01-02……23-24. It is the
programmed time to switch the appliance. The programmed time
will be cancelled when to turn off the appliance manually each time.
The programmed time remains unchanged if the appliance stops to
work due to water full or during defrosting.
11
MEMORY FUNCTION: The appliance maintains its settings during a
power failure.
IV.DRAINING THE COLLECTED WATER
When the water tank is full, the tank full indicator light will turn on,
the operation will stop automatically and the buzzer will beep 15
times to alert the user, that thewater needs to be emptiedfrom the
water tank.
Emptying the Water Tank
1.Lightly press on the sides of the water tank with both hands and
pull it out gently.
2.Discard the collected water
12
NOTE
1.Do not remove the float from the water tank. The water full sensor
will no longer be able to detect the water level correctly without the
float and water may leak from the water tank.
2.If the water tank is dirty, wash it with cold or lukewarm water.Do
not use detergent, scouring pads, chemically treated dust cloths,
gasoline, benzene, thinner, or other solvents, as these can scratch
and damage the water tank and cause water leakage.
3.When reattaching the water tank, press the water tank firmly into
place with both hands. If the water tank is notpositioned properly,
the “TANK FULL” sensor will be activated, and the appliance will not
operate.
Continuous Water Drainage
The appliance features a continuous water drainage port. Use a
plastic pipe (with an inner diameter of 10mm) and insert it into the
drain hole (on intermediate plate), then feed the pipe out from the
back of the appliance and place the end of the pipe into household
drainage system. The water in the water tank now can be
continuously drained out from the continuous port on the appliance.
13
V.MAINTENANCE
Cleaning
1.To clean the Body
Wipe it with a soft damp cloth.
2.To Clean the Air Filter
A: Open the inlet grill and remove the air filter
B: Clean the air filter
Run a vacuum cleaner lightly over the surface of the air filter to
remove dirt. If the air filter is exceptionally dirty, wash it with warm
water and a mild cleanser and dry thoroughly.
14
C: Attach the air filter
Insert the filter into the grill smoothly, and place the inlet grill into
the right place.
Storage
When the appliance is not being used for a long period of time and
you want to store it note the following steps:
1.Empty the water tank.
2.Fold up the mains power cable and put it in the water tank.
3.Clean the air filter
4.Store in a cool and dry place.
15
Clearance
Maintain the minimum clearance around the appliance when it is
operating as shown in the left drawing.
16
VI.TROUBLESHOOTING
If a condition listed below occurs, check the following items before calling
customerservice.
Problem
Possible Cause
Solution
The appliance
doesn't
operate
Has the mains power
cable become
disconnected?
Plug the mains
power cable
correctly into a
mains power wall
socket.
Is the water tank full
indication
lamp blinking? (Is the
water tank
full or in a wrong
position.)
Empty the water
tank and then
reattach the water
tank correctly.
Is the temperature of
the
room above 35or
below
5?
The protection
device is
activated and the
appliance cannot be
started.
The
dehumidifying
function
doesn't work
Is the air filter clogged?
Clean the air filter
as instructed in the
"Cleaning" section.
Is the intake duct or
discharge duct
obstructed?
Remove the
obstruction from
the discharge duct
or intake duct.
No air is
discharged
Is the air filter clogged?
Clean the air filter
as instructed in the
"Cleaning" section.
Operation is
noisy
Is the appliance tilted or
unsteady?
Move the appliance
to a stable, sturdy
location.
Is the air filter clogged?
Clean the air filter
as instructed in the
"Cleaning" section.
17
VII.NOTE FOR MAINTENANCE WORK
1.Checks to the area
Prior to beginning work on systems containing flammable
refrigerants, safety checks are necessary to ensure that the risk of
ignition is minimized repair to the refrigerating system, the
following precautions must be complied with prior to conducting
work on the system.
2.Work procedure
Work must be undertaken under a controlled procedure so as to
minimize the risk of a flammable gas or vapor being present while
the work is being performed.
3.General work area
All maintenance staff and others working in the local area must be
instructed on the nature of work being carried out. Work in confined
spaces must be avoided. The area around the workspace must be
sectioned off. Ensure that the conditions within the area have been
made safe for the control of flammable material.
4.Checking for presence of refrigerant
The area must be checked with an appropriate refrigerant detector
prior to and during the work, to ensure that the technician is aware
of the potentially flammable atmosphere. Ensure that the leak
detection equipment being used is suitable for use with flammable
refrigerant, i.e.non sparking, adequately sealed or intrinsically safe.
5.Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or
any associated parts, appropriate fire extinguishing equipment
must be available to hand. Have a dry powder or CO2 fire
extinguisher adjacent to the area.
6.No ignition sources
No person carrying out work in relation to a refrigerant system
which involves exposing any pipe work that contains or has
contained flammable refrigerant may use any sources of ignition in
such a manner that could lead to the risk of fire or explosion. All
possible ignition sources, including cigarette smoking, should be
kept sufficiently far away from the site of installation, repairing,
removing and disposal, during which flammable refrigerant can
possibly be released to the surrounding space. Prior to any work
taking place, the area around the equipment is must surveyed to
18
make sure that there are no flammable hazards or ignition risks. “No
Smoking” signs must be displayed.
7.Ventilated area
Ensure that the area is in the open or that it is adequately ventilated
before breaking into the system or conducting any hot work.
Adequate ventilation must continue during the period that the work
is carried out. The ventilation should safely disperse any released
refrigerant and preferably expel it externally into the atmosphere.
8.Checks to the refrigeration equipment
Where electrical components are being changed, they must be fit
for the purpose and to the correct specification. At all times the
manufacturer’s maintenance and service guidelines must be
followed. If in doubt consult the manufacturer’s technical
department for assistance.
The following checks must be applied to installations using
flammable refrigerants:
- the charge size in accordance with the room size within which the
refrigerant containing parts are installed;
- the ventilation machinery and outlets are operating adequately
and are not obstructed.
9.Checks to electrical devices
Repair and maintenance to electrical components must include
initial safety checks and components inspection procedures. If a
fault exists that could compromise safety, then no electrical supply
must be connected to the circuit until it is satisfactorily dealt with. If
the fault cannot be corrected immediately but it is necessary to
continue operation, an adequate temporary solution must be used.
This must be reported to the owner of the equipment so all parties
are advised.
Initial safety checks must include:
-Capacitors are discharged: this must be done in a safe manner to
avoid any possibility of sparking;
-No live electrical components and wiring should be exposed while
charging, recovering or purging the system;
-that there is continuity of earth bonding
10.Repairs to sealed components
19
During repairs to sealed components, all electrical supplies must be
disconnected from the equipment being worked upon prior to any
removal of sealed covers, etc.
If it is absolutely necessary to have an electrical supply to
equipment during servicing, then a permanently operating form of
leak detection must be located at the most critical point to warn of a
potentially hazardous situation.
Particular attention must be paid to the following to ensure that by
working on electrical components, the casing is not altered in such a
way that the level of protection is affected. This must include
damage to cables, excessive number of connections, terminals not
made to original specification, damage to seals, incorrect fitting of
glands, etc.
Ensure that the apparatus is mounted securely.
Ensure that seals or sealing materials have not degraded to such an
extent that they no longer serve the purpose of preventing the
ingress of flammable atmospheres. Replacement parts must be in
accordance with the manufacturer’s specifications.
NOTE: The use of silicon sealant may inhibit the effectiveness of
some types of leak detection equipment. Intrinsically safe
components do not have to be isolated prior to working on them.
11.Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the
circuit without ensuring that this will not exceed the permissible
voltage and current permitted for the equipment in use.
Intrinsically components are the only types that can be worked on
while live in the presence of a flammable atmosphere. The test
apparatus must be at the correct rating.
Replace components only with parts specified by manufacturer.
Other parts may result in the ignition of refrigerant in the
atmosphere from a leak.
12.Cabling
Check that the cabling will not be subject to wear, corrosion,
excessive pressure, vibration, sharp edges or any other adverse
environmental effects. The check must also take into account the
effects of aging or continual vibration from sources such as
compressors or fans.
13.Leakage detection for flammable refrigerants
20
Under no circumstances should any potential sources of ignition be
used in the searching for or detection ofrefrigerant leaks. A halide
torch (or any other detector using a naked flame) must not be used.
14.Leak detection methods
The following leak detection methods are acceptable for systems
containing flammable refrigerant.
Electronic leak detectors must be used to detect flammable
refrigerants, but the sensitivity may not be adequate, or may need
recalibration (Detection equipment must be calibrated in a
refrigerant-free area.) Ensure that detector is not a potential source
of ignition and is suitable for the refrigerant used.
Leak detection fluids are suitable for use with most refrigerants but
the use of detergents containing chlorine must be avoided as the
chlorine may react with the refrigerant and corrode the copper
pipe-work.
If a leak is suspected, all naked flames must be
removed/extinguished.
If a leakof refrigerant is foundwhich requires brazing, allof the
refrigerant must be recovered from the system. Oxygen free
nitrogen (OFN) must then be purged through the system both
before and during the brazing process.
15.Removal and evacuation
When breaking into the refrigerant circuit to make repairs-or for any
other purpose-conventional procedures must be used. However, it
is important that best practice is followed since flammability is a
consideration. The following procedures must be adhered to:
Remove refrigerant;
Purge the circuit with inert gas;
Evacuate;
Purge again with inert gas;
Open the circuit by cutting or brazing.
The refrigerant charge must be recovered into the correct recovery
cylinders. The system must be” flushed” with OFN to render the
appliance safe. This process may need to be repeated several times.
Compressed air or oxygen must not be used for this task.
Flushing must be achieved by breaking the vacuum in the system
with OFN and continuing to fill until the working pressure is
achieved, then venting to atmosphere, and finally pulling down to a
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112

SENZ SEDH3010 AVFUKTER Bruksanvisning

Typ
Bruksanvisning