Philips AC1215/10 Användarmanual

Kategori
Luftrenare
Typ
Användarmanual
AC1215
EN User manual 1
DA Brugervejledning 17
DE Benutzerhandbuch 33
ES Manual del usuario 51
FI yttöopas 68
FR Mode d’emploi 85
IT Manuale utente 102
NL Gebruiksaanwijzing 120
NO Brukerhåndbok 137
PT Manual do utilizador 153
SV Användarhandbok 170
© 2020 Koninklijke Philips N.V.
All rights reserved.
4241 210 93083
1 2
J K L M N
E
F
G
H
I
A
B
D
C
3s
3s
3s
3s
Contents
1 Important 2
2 Your air purier 5
Product overview 5
Controls overview 5
3 Getting started 5
Installing the lter 5
4 Using the air purier 6
Understanding the air quality light 6
Turning on and o 6
Changing the fan speed 7
Light sensor 7
Night sensing mode 7
Set the child lock 8
5 Cleaning 9
Cleaning the body of the air
purier 9
Cleaning the air quality sensor 9
Cleaning the pre-lter 10
6 Replacing the lter 11
Filter replacement indicator 11
Replacing the lters 11
Filter reset 12
7 Storage 12
8 Troubleshooting 13
1EN
English
9 Guarantee and service 15
Order parts or accessories 15
10 Notices 15
Electromagnetic elds (EMF) 15
Recycling 16
2 EN
service center authorized
by Philips, or similarly
qualified persons in order
to avoid a hazard.
Do not use the appliance
if the plug, the power
cord, or the appliance
itself is damaged.
This appliance can be
used by children aged
from 8 years and above
and persons with reduced
physical, sensory or
mental capabilities or
lack of experience and
knowledge if they have
been given supervision or
instruction concerning use
of the appliance in a safe
way and understand the
hazards involved. Child
shall not play with the
appliance. Cleaning and
maintenance shall not be
made by children without
supervision.
Do not block the air inlet
and outlet, e.g. by placing
items on the air outlet or
in front of the air inlet.
Make sure that foreign
objects do not fall into the
appliance through the air
outlet.
1 Important
Read this user manual carefully before
you use the appliance, and save it for
future reference.
Danger
Do not let water or any
other liquid or flammable
detergent enter the
appliance to avoid electric
shock and/or a fire
hazard.
Do not clean the
appliance with water,
any other liquid, or a
(flammable) detergent to
avoid electric shock and/
or a fire hazard.
Do not spray any
flammable materials
such as insecticides or
fragrance around the
appliance.
Warning
Check if the voltage
indicated on the
appliance corresponds to
the local power voltage
before you connect the
appliance.
If the power cord is
damaged, you must have
it replaced by Philips, a
an air conditioner to
prevent condensation
from dripping onto the
appliance.
Make sure all filters
are properly installed
before you switch on the
appliance.
Only use the original
Philips filters specially
intended for this
appliance. Do not use any
other filters.
Combustion of the filter
may cause inreversible
human hazard and/or
jeopardize other lives. Do
not use the filter as fuel or
for similar purpose.
Avoid knocking against
the appliance (the air inlet
and outlet in particular)
with hard objects.
Always lift or move the
appliance by the handle
on back side of the
appliance.
Do not insert your fingers
or objects into the air
outlet or the air inlet to
prevent physical injury
or malfunctioning of the
appliance.
Caution
This appliance is not
a substitute for proper
ventilation, regular
vacuum cleaning, or use
of an extractor hood or
fan while cooking.
If the power socket used
to power the appliance
has poor connections,
the plug of the appliance
becomes hot. Make
sure that you plug the
appliance into a properly
connected power socket.
Always place and use
the appliance on a
dry, stable, level, and
horizontal surface.
Leave at least 20cm
free space behind and
on both sides of the
appliance and leave at
least 30cm free space
above the appliance.
Do not place anything on
top of the appliance.
Do not sit or stand on
the appliance. Sitting or
standing on the appliance
may lead to potential
injuiry.
Do not place the
appliance directly below
3EN
English
Do not use the appliance
in wet surroundings or in
surroundings with high
ambient temperatures,
such as the bathroom,
toilet, or kitchen.
The appliance does
not remove carbon
monoxide (CO) or radon
(Rn). It cannot be used
as a safety device in
case of accidents with
combustion processes
and hazardous chemicals.
If you need to move the
appliance, disconnect the
appliance from the power
supply first.
Do not move the
appliance by pulling its
power cord.
Always wash your hands
thoroughly after changing
or cleaning a filter.
Do not use this appliance
when you have used
indoor smoke-type insect
repellents or in places
with oily residues, burning
incense, or chemical
fumes.
Do not use the appliance
near gas appliances,
heating devices or
fireplaces.
Always unplug the
appliance after use
and before cleaning,
or carrying out other
maintenance or replacing
the filters.
Do not use the appliance
in a room with major
temperature changes,
as this may cause
condensation inside the
appliance.
To prevent interference,
place the appliance at
least 2 meters away from
electrical appliances that
use airborne radio waves
such as TVs, radios, and
radio-controlled clocks.
The appliance is only
intended for household
use under normal
operating conditions.
4 EN
3 Getting started
Installing the lter
Note
Make sure the air purifier is unplugged
from the electrical outlet before
installing the filter.
Make sure the side of the filter with the
tag is pointing towards you.
1 Pull the bottom part of the front
panel and then gently lift to remove
it from the air purifier (Fig.c).
2 Press the clip down (1) and pull the
pre-filter towards you (2) (Fig.d).
3 Remove all filters (Fig.e).
4 Remove all packaging materials
from the filter (Fig.f).
5 Place the thick filter (FY1410) into
the air purifier and then the thin AC
filter (FY1413) (Fig.g). The model
numbers are shown on each filter.
6 Attach the pre-filter back into the
air purifier (Fig.h).
Note
Make sure the side with the clip is
pointing towards you, and that all
hooks of the pre-filter are properly
attached to the purifier.
7 Reattach the front panel by
pressing the top part of the panel
onto the top of the air purifier (1).
Then, gently push the panel against
the body of the air purifier (2)
(Fig.i).
8 Wash your hands thoroughly after
installing filters.
2 Your air purifier
Congratulations on your purchase, and
welcome to Philips!
To fully benefit from the support that
Philips offers, register your product at
www.philips.com/welcome.
Product overview
A Control panel
B Air quality light
C Air outlet
D Air quality sensor
E
NanoProtect filter Series 3
(FY1410)
F NanoProtect filter AC (FY1413)
G Pre-filter
H Air inlet
I Front panel
Controls overview
J On/Off button
K Night sensing mode button
L Display screen
M Fan speed button
N Child lock button
5EN
English
Turning on and o
Note
Always place the air purifier on a
stable, horizontal, and level surface
with the front of the unit facing away
from walls or furniture.
For optimum purification performance,
close doors and windows.
Keep curtains away from the air inlet or
air outlet.
1 Put the plug of the air purifier in the
wall outlet.
2 Touch to switch on the air purifier
(Fig.j).
» The air purifier beeps.
» The air purifier operates under
the auto mode by default.
» When the air purifier is warming
up, “ displays on the screen.
» After measuring the air
quality for approximately
30 seconds, the air quality
sensor automatically selects
the appropriate air quality light
color.
3 Touch and hold for 3 seconds to
switch off the air purifier.
Note
If the air purifier stays connected to
the electrical outlet after turning OFF,
the air purifier will operate under the
previous settings when turned ON
again.
If the air purifier accidentally shuts off
during running, it restarts automatically
and operates under previous settings
when the power supply is resumed.
4 Using the air
purifier
Understanding the air
quality light
Air quality light
color
Air quality level
Blue
Good
Blue-violet
Fair
Red-purple
Poor
Red
Very poor
The air quality light automatically goes
on when the air purifier is switched on,
and lights up all colors in sequence.
After approximately 30 seconds, the
air quality sensors select the color that
corresponds to the surrounding air
quality of airborne particles.
6 EN
Light sensor
With the light sensor, the air purifier can
work according to the ambient light.
When the ambient light dims for
10 seconds, all the lights on the control
panel will be off slowly. During this
period, you can touch any of the
buttons, all lights will be on again. If you
don't perform other operations within
10 seconds, all lights will be off.
After the ambient light becomes bright
and lasts at least for 10 seconds, all
lights will be on again.
Night sensing mode
You can activate the night sensing
mode in two ways.
Activating the night sensing
mode manually
Before you go to sleep, touch
manually to activate the night
sensing mode (Fig.o).
» If the air quality light is blue,
the air purifier directly goes to
the night sensing mode. The air
purifier operates quietly and the
air quality light will be dimmed.
» If the air quality light is not blue,
the air purifier operates under
turbo mode for a maximum of
10 minutes, the air quality light
blinks slow during this time, and
then goes to the night sensing
mode.
Changing the fan speed
There are several fan speeds available.
You can choose the auto mode, speed
1, 2, 3 or turbo mode (t).
Auto(A)
Touch the fan speed button
repeatedly to select the auto mode
(Fig.k).
Allergen mode
The specially designed allergen
mode can effectively reduce common
allergens such as pollen and pet
dander.
Touch the fan speed button to
select the Allergen mode (Fig.l).
» Auto (A) and display on the
screen.
Manual
Touch the fan speed button
repeatedly to select the fan speed
you need (Fig.m).
Turbo (t)
In turbo mode, the air purifier operates
on the highest speed.
Touch the fan speed button to
select the turbo mode (t) (Fig.n).
7EN
English
Set the child lock
1 Touch and hold the child lock
button for 3 seconds to activate
child lock (Fig.p).
» The child lock icon displays
on the screen.
» When the child lock is on,
all the other buttons are not
responsive, only the child lock
icon blinks.
2 Touch and hold the child lock
button for 3 seconds again to
deactivate child lock (Fig.q).
» The child lock icon
disappears.
Note
The child lock function is automatically
unlocked when the pre-filter cleaning
code or the filter replacement code
displays on the screen.
Auto activating the night
sensing mode
When the air purifier operates in auto
mode or allergen mode, if the light
sensor detects the lights in your room
are turned off, the air purifier goes to
the night sensing mode automatically.
The air purifier will adjust the fan speed
in real-time to make sure the air in your
room is clean. The air quality light will
be dimmed.
Note
The light sensor detects the lights in
your room after 11 hours in the night
sensing mode.
If the lights in your room are turned
on, the air purifier will quit the night
sensing mode and operate under the
previous mode. The air quality light
and the display will be on again.
To exit the night sensing mode
manually, touch or button.
8 EN
Cleaning the air quality
sensor
Clean the air quality sensor every
2 months for optimal functioning of the
purifier.
Note
If the air purifier is used in a dusty
environment, it may need to be
cleaned more often.
If the humidity level in the room is
very high, condensation may develop
on the air quality sensor and the air
quality light may indicate a more poor
air quality even though the air quality
is actually good. If this occurs, clean
the air quality sensor or use the air
purifier on a manual speed setting.
1 Switch off the air purifier and
unplug from the wall outlet.
2 Clean the air quality sensor inlet
and outlet with a soft brush (Fig.r).
3 Remove the air quality sensor cover
(Fig.s).
4 Clean the air quality sensor, the
dust inlet and the dust outlet with a
damp cotton swab (Fig.t).
5 Dry all parts thoroughly with a dry
cotton swab.
6 Reattach the air quality sensor
cover (Fig.u).
Note
Always keep air quality cover close
during the air purifier is working.
5 Cleaning
Note
Always turn the air purifier off and
unplug the air purifier from the
electrical outlet before cleaning.
Never immerse the air purifier in water
or any other liquid.
Never use abrasive, aggressive, or
flammable cleaning agents such as
bleach or alcohol to clean any part of
the air purifier.
Only the pre-filter is washable. The air
filter is not washable.
Do not attempt to clean the filters or
air quality sensor with a vacuum.
Cleaning the body of the
air purier
Regularly clean the inside and outside
of the air purifier to prevent dust from
collecting.
1 Use a soft, dry cloth to clean both
the interior and exterior of the air
purifier (Especially for the front
cover).
2 The air outlet can also be cleaned
with a dry, soft cloth.
3 Detach the front cover from the air
purifier and wash it under running
tap water.
9EN
English
8 Put the plug of the air purifier in the
wall outlet.
9 Touch and hold the for
3 seconds to reset the pre-filter
cleaning time (Fig.x).
10 Wash your hands thoroughly after
installing filters.
Cleaning the pre-lter
Clean the pre-filter when F0 is displayed
on the screen (Fig.v).
1 Switch off the air purifier and
unplug from the wall outlet.
2 Pull the bottom part of the front
panel and then gently lift to remove
it from the air purifier (Fig.c).
3 Press the clip down (1) and pull the
pre-filter towards you (2) (Fig.d).
4 If the pre-filter is very dirty, use a
soft brush to brush away the dust.
Then wash the pre-filter under
running tap water (Fig.w).
5 Allow the pre-filter to air dry
thoroughly before placing back in
the air purifier.
Note
To optimize the lifetime of the pre-
filter, make sure it dries completely
after cleaning.
Wash your hands after handling the
filter.
6 Put the pre-filter back into the air
purifier (Fig.h).
Note
Make sure the side with the clip is
pointing towards you, and that all
hooks of the pre-filter are properly
attached to the air purifier.
7 To reattach the front panel, press
the top part of the panel onto the
top of the air purifier (1). Then,
gently push the panel against the
body of the air purifier (2) (Fig.i).
10 EN
Filter alert light
status
Action
A3 displays on
the screen
Replace
NanoProtect filter
Series 3 (FY1410)
C7 displays on
the screen
Replace the
NanoProtect filter AC
(FY1413)
A3 and C7
display on
the screen
alternately
Replace both filters
1 Turn off the air purifier and unplug
from the wall outlet.
2 Take out the used air filter according
to the filter alert light status
displayed on the screen (Fig.y).
Discard used filter.
Note
Do not touch the pleated filter surface,
or smell the filter as it has collected
pollutants from the air.
3 Remove all packaging material from
the new filter (Fig.f).
4 Place the new filters into the air
purifier (Fig.g).
5 Put the plug of the air purifier in the
wall outlet.
6 Touch and hold the for 3 seconds
to reset the filter lifetime counter
(Fig.z).
7 Wash your hands after changing a
filter.
6 Replacing the
filter
Filter replacement
indicator
This air purifier is equipped with a
filter replacement indicator to make
sure that the air purification filter is in
optimal condition when the air purifier
is operating. When the filters need to be
replaced, the filter code displays on the
screen.
If the filters are not replaced in 14 days,
the air purifier will stop operating and
automatically lock.
Replacing the lters
Note
The air filters are not washable or
reusable.
Always turn off the air purifier and
unplug from the electrical outlet
before replacing the filters.
Do not clean the filter with a vacuum.
11EN
English
Filter reset
You can replace filters even if there is
no filter replacement code displayed on
the screen. After replacing a filter, you
need to reset the filter lifetime counter
manually.
1 Touch and simultaneously
for 3 seconds to enter the filter reset
mode (fig.{).
» Code (A3) of the NanoProtect
filter Series 3 displays on the
screen.
2 Touch and hold for 3 seconds to
force reset the filter lifetime counter
of the NanoProtect filter Series 3
(fig.z).
3 Code (C7) of the Nanoprotect filter
AC displays on the screen after the
lifetime counter of the NanoProtect
filter Series 3 has been reset (fig.|).
4 Touch and hold for 3 seconds to
force reset the filter lifetime counter
of the NanoProtect filter AC and exit
the filter reset mode (fig.}).
12 EN
7 Storage
1 Turn off the air purifier and unplug
from the wall outlet.
2 Clean the air purifier, air quality
sensor and pre-filter (see chapter
“Cleaning”).
3 Let all parts dry thoroughly before
storing.
4 Wrap the filter and pre-filter
separately in air tight plastic bags.
5 Store the air purifier, the filter and
pre-filter in a cool, dry location.
6 Always thoroughly wash hands
after handling filters.
8 Troubleshooting
This chapter summarizes the most common problems you could encounter with the air
purifier. If you are unable to solve the problem with the information below, visit
www.philips.com/support or contact the Consumer Care Center in your country.
Problem Possible solution
The air purier
does not work
even though it is
plugged in to the
wall outlet and
switched on.
Try a different electrical outlet or check the wall switch.
The filter alert status is displaying the filter code. Replace
the corresponding filter and reset the filter lifetime counter
(see chapter “Replacing the filter”).
If the problem persists, contact the Consumer Care Center
in your country.
The air purier
does not work
even though it is
switched on.
The filter replacement indicator has been on continuously
but you have not replaced the corresponding filter, and the
air purifier is now locked. In this case, replace the filter and
reset the filter lifetime counter.
The air purier
accidentally
powers o.
The air purifier restarts automatically and goes to the
previous mode when the power resumes.
The airow that
comes out of
the air outlet
is signicantly
weaker than
before.
The pre-filter is dirty. Clean the pre-filter (see chapter
“Cleaning”).
The air quality
does not improve,
even though the air
purier has been
operating for a
long time.
One of the filters has not been placed in the air purifier or
the filter is not placed properly. Make sure that all filters
are properly installed in the following order, starting with
the innermost filter:
1) NanoProtect filter Series 3 (FY1410);
2) NanoProtect filter AC (FY1413) 3) pre-filter.
The air quality sensor is wet. Make sure that the air quality
sensor is clean and dry (see chapter “Cleaning”).
13EN
English
Problem Possible solution
The color of the air
quality light always
stays the same.
The air quality sensor is dirty. Clean the air quality sensor
(see chapter “Cleaning”).
The air purier
produces a
unpleasant smell.
The first few times you use the air purifier, it may produce
a plastic smell. This is normal. The air purifier may also
produce an unpleasant smell when the filter is dirty. In this
case, clean or replace the appropriate filter.
If the air purifier produces a burnt odor, switch OFF and
unplug from the electrical outlet. Contact the Consumer
Care Center in your country.
The air purier is
loud.
If the air purifier is too loud, change the fan speed to a
lower fan speed level. When using the air purifier in a
bedroom at night, choose the night sensing mode or select
a lower fan speed level.
The air purier still
indicates that I
need to replace a
lter, but I already
did.
Perhaps you did not reset the filter lifetime counter. Plug
in the air purifier, touch to switch on the air purifier, and
touch and hold the for 3 seconds.
Error codes “E1”,
“E2”, “E3” or “E4”
displays on the
screen.
The air purifier has malfunctions. Contact the Consumer
Care Center in your country.
14 EN
9 Guarantee and
service
If you need information or if you have a
problem, please visit the Philips website
at www.philips.com or contact the
Philips Consumer Care Center in your
country (you find its phone number
in the worldwide guarantee leaflet). If
there is no Consumer Care Centre in
your country, go to your local Philips
dealer.
Order parts or
accessories
If you have to replace a part or want to
purchase an additional part, go to your
Philips dealer or visit www.philips.com/
support.
If you have problems obtaining the
parts, please contact the Philips
Consumer Care Center in your country
(you can find its phone number in the
worldwide guarantee leaflet).
15EN
English
10 Notices
Electromagnetic elds
(EMF)
This Philips appliance complies with all
applicable standards and regulations
regarding exposure to electromagnetic
fields.
Compliance with EMF
Koninklijke Philips N.V. manufactures
and sells many products targeted at
consumers, which, like any electronic
apparatus, in general have the ability
to emit and receive electromagnetic
signals.
One of Philips' leading Business
Principles is to take all necessary health
and safety measures for our products,
to comply with all applicable legal
requirements and to stay well within the
EMF standards applicable at the time of
producing the products.
Philips is committed to develop,
produce and market products that
cause no adverse health effects. Philips
confirms that if its products are handled
properly for their intended use, they
are safe to use according to scientific
evidence available today.
Philips plays an active role in the
development of international EMF
and safety standards, enabling Philips
to anticipate further developments in
standardization for early integration in
its products.
16 EN
Recycling
This symbol means that this product
shall not be disposed of with normal
household waste (2012/19/EU).
Follow your country’s rules for the
separate collection of electrical and
electronic products. Correct disposal
helps prevent negative consequences
for the environment and human health.
Indhold
1 Vigtigt 18
2 Din luftrenser 21
Produktoversigt 21
Oversigt over knapper 21
3 Kom godt i gang 21
Montering af lteret 21
4 Brug af luftrenseren 22
Forklaring af luftkvalitetslyset 22
Sådan tændes og slukkes
apparatet 22
Ændring af blæserhastighed 22
Lyssensor 23
Mørkesensortilstand 23
Indstilling af børnesikring 24
5 Rengøring 24
Rengøring af luftrenserens
kabinet 24
Rengøring af
luftkvalitetssensoren 25
Rengøring af forlteret 25
6 Udskiftning af lteret 26
Indikator for udskiftning af lter 26
Udskiftning af ltre 26
Filternulstilling 27
7 Opbevaring 28
8 Fejlnding 29
17DA
Dansk
9 Garanti og service 31
Bestilling af dele eller tilbehør 31
10 Bemærkninger 31
Elektromagnetiske felter (EMF) 31
Genbrug 32
18 DA
Hvis netledningen
beskadiges, må den
kun udskiftes af Philips,
et autoriseret Philips-
serviceværksted eller en
tilsvarende kvaliceret
fagmand for at undgå
enhver risiko.
Brug aldrig apparatet,
hvis netstik, netledning
eller selve apparatet er
beskadiget.
Dette apparat kan
bruges af børn fra 8 år
og opefter og personer
med reducerede fysiske,
sensoriske eller mentale
evner eller manglende
erfaring og viden, hvis de
er blevet instrueret i sikker
brug af apparatet og
forstår de medfølgende
risici. Lad ikke børn lege
med apparatet. Rengøring
og vedligeholdelse
ikke foretages af børn
uden opsyn.
Luftind- og -udtagene må
ikke blokeres, f.eks. ved at
stille ting på luftudtaget
eller foran luftindtaget.
Sørg for, at
fremmedlegemer ikke
falder ind i apparatet
gennem luftudgangen.
1 Vigtigt
Læs denne brugsvejledning
omhyggeligt igennem, inden apparatet
tages i brug, og gem den til eventuelt
senere brug.
Fare
Lad ikke vand eller
nogen andre væsker
eller brandbare
rengøringsmidler komme
i berøring med apparatet
for at undgå elektrisk stød
og/eller brandfare.
Undlad at rengøre
apparatet med vand
eller andre væsker
eller (brandbart)
rengøringsmiddel for at
undgå elektrisk stød og/
eller brandfare.
Sprøjt ikke brændbare
materialer som f.eks.
insektgift eller parfume
omkring apparatet.
Advarsel
Kontrollér, om den
angivne netspænding
på apparatet svarer til
den lokale netspænding,
før du slutter strøm til
apparatet.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186

Philips AC1215/10 Användarmanual

Kategori
Luftrenare
Typ
Användarmanual