Electrolux EXP34U338CW Bruksanvisning

Typ
Bruksanvisning
EN
Air Conditioner
DA
Klimaanlæg
FI
Ilmastointilaite
NO
Luftkjøler
SV
Luftkonditionering
IT
Condizionatore d’aria
FR
Climatiseur
User Manual
Brugsvejledning
Käyttöohje
Bruksanvisning
Bruksanvisninng
Manuale per l’utente
Manuel D'utilisation
2
23
44
66
86
108
130
EXP26U338CW
EXP26U538CW
EXP34U338CW
EXP35U538CW
EXP26U558CW
EXP26U758CW
EXP26U338HW
EXP26U538HW
EXP34U338HW
EXP35U538HW
EXP26U558HW
2 www.electrolux.com
Subject to change without notice.
Warning / Caution-Safety information.
General information and tips.
Environmental information.
CUSTOMER CARE AND SERVICE
Always use original spare parts.
When contacting our Authorised Service Centre, ensure that you have the following
data available: Model, PNC, Serial Number.
The information can be found on the rating plate.
Register your product for better service:
www.registerelectrolux.com
Buy Accessories, Consumables and Original spare parts for your appliance:
www.electrolux.com/shop
Visit our website to:
Get usage advice, brochures, trouble shooter, service information:
www.electrolux.com/webselfservice
Thank you for purchasing an Electrolux appliance. You’ve chosen a product that brings
with it decades of professional experience and innovation. Ingenious and stylish, it
has been designed with you in mind. So whenever you use it, you can be safe in the
knowledge that you’ll get great results every time. Welcome to Electrolux.
WE’RE THINKING OF YOU
1.
SAFETY INFORMATION .................................................................................. 3
2.
SAFETY INSTRUCTION ................................................................................... 9
3.
UNIT DESCRIPTION ....................................................................................... 12
4.
ACCESSORIES INCLUDED ........................................................................... 12
5.
INSTALLATION INSTRUCTIONS ................................................................... 13
6.
AIR CONDITIONER FEATURES .................................................................... 14
7.
OPERATING INSTRUCTIONS ....................................................................... 14
8.
CARE & CLEANING ........................................................................................ 20
9.
TROUBLE SHOOTING ................................................................................... 21
10.
ENVIRONMENTAL CONCERNS .................................................................... 22
CONTENTS
3ENGLISH
1.
SAFETY INFORMATION
WARNING!
This appliance can be used by children aged from
8 years and above and persons with reduced
physical, sensory or mental capabilities or lack
of experience and knowledge if they have been
given supervision or instruction concerning use
of the appliance in a safe way and understand
the hazards involved.
Children shall not play with the appliance.
If the supply cord is damaged, it must bereplaced
by the manufacturer, its service agent or similarly
qualied persons in order to avoid a hazard.
This manual explains the proper use of your new air
conditioner. Please read this manual carefully before
using the product. This manual should be kept in a safe
place for handy reference.
6\PERO 1RWH ([SODQDWLRQ
:$51,1*
&$87,21
&$87,21
&$87,21
7KLVV\PEROVKRZVWKDWWKLVDSSOLDQFHXVHV
DIODPPDEOHUHIULJHUDQW,IWKHUHIULJHUDQWLVOHDNHG
DQGH[SRVHGWRDQH[WHUQDOLJQLWLRQVRXUFHWKHUH
LVDULVNRIILUH
7KLVV\PEROVKRZVWKDWWKHRSHUDWLRQPDQXDO
VKRXOGEHUHDGFDUHIXOO\
7KLVV\PEROVKRZVWKDWDVHUYLFHSHUVRQQHOVKRXOG
EHKDQGOLQJWKLVHTXLSPHQWZLWKUHIHUHQFHWRWKH
LQVWDOODWLRQPDQXDO
7KLVV\PEROVKRZVWKDWLQIRUPDWLRQLVDYDLODEOHVXFK
DVWKHRSHUDWLQJPDQXDORULQVWDOODWLRQPDQXDO
CAUTION!
Contact authorised service technician for repair
or maintenance of this unit.
Contact the installer for installation of this unit.
4 www.electrolux.com
1.2
Point to Keep in Mind When Using Your
Air Conditioner
CAUTION!
Warnings for use
Do not modify any part of this product.
Do not insert anything into any part of the unit.
Ensure the power supply used has an appropriate
voltage rating. Only use a 220 - 240V, 50Hz, 10A
mains electricity supply. Use of a power supply
with an improper voltage rating can result in
damage to the unit an possibly re.
1.1
Important notes
1. Do not operate unit without the air lter.
2. Do not operate unit near any heat source or open re.
3. Do not expose the unit outside to direct sunlight and rain.
4. Always store or move the unit in an upright position.
5. Do not cover the appliance when in operation
or immediately after use.
6. Always drain condensation before storing unit.
The air conditioner is not intended for use by young
children of inrmed persons without supervision.
Young children should be supervised to ensure
that they do not play with the air conditioner.
There are local council rules regarding maximum
allowable noise levels emitted by air conditioners.
If the power cord is to be replaced, replacement work
shall be performed by authorised personnel only.
Installation work must be performed in accordance
with the national wiring standards by authorised
personnel only (if applicable). Incorrect connection
can cause overheating and re.
Take care not to catch ngers on fan when adjusting
horizontal louvres.
The fuse is 250V 3.15A, ceramic type.
Cleaning and user maintenance shall not be made
by children without supervision. Be aware that
refrigerants may not contain an odour.
5ENGLISH
This power plug must only be plugged into an
appropriate wall socket. Do not use in conjunction
with any extension cords.
Push the power plug securely into the socket and
make sure it is not loose.
Do not pull, deform. or modify the power supply
cord, or immerse it in water. Pulling or misuse of
the power supply cord can result in damage to the
unit and cause electrical shock.
If the supply cord is damaged, it must be replaced
by the manufacturer or its service agent or
a similarly qualied person in order to avoid
a hazard. Use only the manufacturer specied
power cord for replacement.
This appliance must be earthed. This appliance
is equipped with a cord having an earth wire.
The plug must be plugged into an outlet that is
properly installed and earthed. Do not under any
circumstances cut or remove the square earthed
pin (only for UK) from this plug.
CAUTION!
Warning for power supply cord
Always use a anti-explosive circuit breaker or
fuse with the proper amp rating. Do not, under
any circumstances, use wire, pins or other objects
in place of a proper fuse.
In the event of any abnormality with the air conditioner
(eg. a burning smell), do not pull out the plug directly,
open the window for ventilation rstly, then turn the
unit o and disconnect the power supply.
Plug
Grounding tab
6 www.electrolux.com
1.3
Usage cautions
Be sure to turn the unit o and disconnect the power
supply cord before performing any maintenance or
cleaning.
Do not put unit near any heat source or open re when
you replacing the lters.
Do not splash or pour water directly onto the unit. Water
can cause electrical shock or equipment damage.
Drainage should be performed whenever moving the
air conditioner. If any water remains in the tank, it may
spill out while being moved.
To ensure proper drainage, the drainage hose must
have no kinks and must not be elevated during
dehumidication mode. If not, the drained water may
spill out into the room.
The temperature around the drainage hose must not
be below freezing point when used. Drained water may
freeze inside the hose, causing water inside the unit to
overow into the room.
Do not block the exhaust air outlet with obstacles. Cooling
performance may be reduced or stop completely.
Provide a anti-explosive residual current device (RCD)
in order to protect against electric shock in accordance
with British Standard and Wiring Rules.
Exposure to direct airow for an extended period of
time could be hazardous to your health. Do not expose
occupants, pets, or plants to direct airow for extended
periods of time.
Do not use this air conditioner for non-specied special
purposes (e.g. preserving precision devices, food, pets,
plants, and art objects). Usage in such a manner could
harm such property.
Do not use means to accelerate the defrosting process
or to clean, other than those recommended by the
manufacturer.
(only for UK)
Plug
Square earthed pin
7ENGLISH
The appliance shall be stored in a room without
continuously operating ignition sources (for example:
open ames, an operating gas appliance or an
operating electric heater).
Do not pierce or burn.
Compliance with national gas regulations shall
be observed.
Keep ventilation openings clear of obstruction.
The appliance shall be stored in a well-ventilated area
where the room size larger than 12 m
2
.
WARNING!
Thoroughly read all of the warnings.
When defrosting and cleaning the appliance, do
not use any tools other than those recommended
by the manufacturing company.
The appliance must be placed in an area without
any continuous sources of ignition (for example:
open ames, gas or electrical appliances in
operation).
Do not puncture and do not burn.
Refrigerant gases can be odourless.
The appliance must be installed, used and stored
in an area that is greater than 12 m
2
.
This appliance contains a certain number of
grams (see rating label back of unit) of R290
refrigerant gas.
R290 is a refrigerant gas that complies with the
European directives on the environment. Do not
puncture any part of the refrigerant circuit.
If the appliance is installed, operated or stored in
a nonventilated area, the room must be designed
to prevent the accumulation of refrigerant leaks
resulting in a risk of re or explosion due to ignition
PLEASE NOTE: CHECK THE PLATE FOR THE TYPE
OF REFRIGERANT GAS USED IN YOUR APPLIANCE.
Specic information regarding appliances with R290
refrigerant gas.
8 www.electrolux.com
of the refrigerant caused by electric heaters,
stoves, or other sources of ignition.
The appliance must be stored in such a way
as to prevent mechanical failure.
Individuals who operate or work on the refrigerant
circuit must have the appropriate certication
issued by an accredited organisation that ensures
competence in handling refrigerants according
to a specic evaluation recognized by associations
in the industry.
Repairs must be performed based on the
recommendations from the manufacturing
company. Maintenance and repairs that require
the assistance of other qualied personnel
must be performed under the supervision of
an individual specied in the use of ammable
refrigerants.
Transport of equipment containing ammable
refrigerants
See transport regulations.
Marking of equipment using signs
See local regulations.
Disposal of equipment using ammable refrigerants
See national regulations.
Storage of equipment/appliances
The storage of equipment should be in accordance with
the manufacturer’s instructions.
Storage of packed (unsold) equipment
Storage package protection should be constructed such
that mechanical damage to the equipment inside the
package will not cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted
to be stored together will be determined by local
regulations.
1.4
Additional information
9ENGLISH
2.2
Warning during usage
To prevent injury to the user or other
people and property damage, the
following instructions must be followed.
Incorrect operation due to ignoring
instructions may cause harm or damage.
The seriousness is classied by the
following indications:
This symbol indicates the possibility
of death or serious injury.
Warning during usage
This symbol indicates the possibility
of injury or damage to property.
WARNING!
WARNING!
CAUTION!
Meanings of symbols used in this manual
are shown below:
This symbol indicates never
to do this.
This symbol indicates always
do this.
2.
SAFETY INSTRUCTION
2.1
Notes on Operation
Allow 4 minutes for the compressor
to restart cooling. If you turn the air
conditioner o and immediately restart
it, allow 4 minutes for the compressor
to restart cooling. There is an electronic
device in the unit that keeps the
compressor turned o for 4 minutes
for safety.
In the event of a power failure during
use, allow 4 minutes before restarting
the unit. After power is reinstated, restart
the air conditioner. If the power was o
for less than four minutes, be sure to wait
at least four minutes before restarting
the unit. if you restart the air conditioner
within four minutes, a protective device
in the unit may cause the compressor
to shut o. This protective device will
prevent cooling for about 5 minutes. Any
previous setting will be cancelled and
the unit will return to its initial setting.
When you turn the unit o in cooling
mode, the compressor will shut o
immediately and the upper/under fan
motor will stop running after 5 seconds;
if operate the unit to fan mode from
cooling mode, the compressor will shut
o immediately and the under fan motor
will stop running after 5 seconds; and if
operate the unit to heating mode from
cooling mode, the compressor will shut
o immediately and the under fan motor
will stop running after 30 seconds.
Low temperature operation: Is your
unit freezing up? Freezing may occur
when the unit is set close to 18°C in
low ambient temperature conditions,
especially at night. In these conditions,
a further temperature drop may cause the
unit to freeze. Setting the unit to a higher
temperature will prevent it from freezing.
Dehumidication mode increases room
temperature. The unit generates heat
during dehumidication mode and the
room temperature will rise. Warm air
will be blown out from the exhaust air
outlet, but this is normal and does not
indicate a problem with the unit.
This air conditioner blows the warm air
generated by the unit outside the room
via the exhaust hose while in cool mode.
In the mean time, the same amount
of air will enter the room from outside
through any openings of the room.
Any person who is involved with working
on or breaking into a refrigerant circuit
should hold a current valid certicate
from an industry-accredited assessment
authority, which authorises their
competence to handle refrigerants
safely in accordance with an industry
recognised assessment specication.
Servicing shall only be performed
as recommended by the equipment
manufacturer. Maintenance and repair
requiring the assistance of other skilled
personnel shall be carried out under the
supervision of the person competent in
the use of ammable refrigerants.
The working temperature range of the
air conditioner is 16-35°C (60-95°F)
under cooling mode; 5-27°C (41-80°F)
under heating mode.
10 www.electrolux.com
Warning Meaning
Plug in power plug properly Otherwise, it may cause electric shock,
re and explosion due to excess heat
generation
Do not operate or stop the unit by
inserting or pulling out Die power plug
It may cause electric shock, re and
explosion due to heat generation
Do not damage or use an unspecied
power cord
It may cause electric shock, re and
explosion. If the power cord is damaged,
it must be replaced by the manufacturer
or an authorised service centre or
a similarly qualied person in order
to avoid a hazard
Do not modify power cord length or
share the outlet with other appliances
It may cause electric shock, re and
explosion due to heat generation
Do not operate with wet hands or in
damp environment
It may cause electric shock
Do not direct airow at room occupants This could harm your health
Always ensure eective earthing Incorrect earthing may cause electric
shock
Do not allow water to run into electric
parts
It may cause failure of unit or electric
shock
Always install circuit breaker and
a dedicated power circuit
Incorrect installation may cause electric
shock, re and explosion
Unplug the unit if strange sounds, smell,
or smoke comes from it
It may cause electric shock, re and
explosion
Do not use the socket if it is loose
or damaged
It may cause electric shock, re and
explosion
Do not open the unit during operation It may cause electric shock, re and
explosion
Keep rearms away It may cause re and explosion
Do not use the power cord close
to heating appliances
It may cause electric shock, re and
explosion
Do not use the power cord near
ammable gas or combustibles, such
as gasoline, benzene, thinner, etc.
It may cause electric shock, re and
explosion
Ventilate room before operating air
conditioner if there is a gas leakage
from another appliance
It may cause explosion, re, explosion
and burns
Do not disassemble or modify unit It may cause failure and electric shock
11ENGLISH
CAUTION!
Caution Meaning
When the air lter is to be removed,
do not touch the metal parts of the unit
It may cause an injury
Do not clean the air conditioner with
water
Water may enter the unit and degrade the
insulation. It may cause an electric shock
Ventilate the room well when used
together with a stove, etc.
An oxygen shortage may occur
When the unit is to be cleaned, switch
o, and turn o the circuit breaker
Do not clean unit when power is on as
it may cause re, explosion and electric
shock, it may cause an injury
Do not place a pet or house plant where
it will be exposed to direct air ow
This could injure the pet or plant
Do not use for special purposes Do not use this air conditioner to
preserve precision devices, food, pets,
plants, and art objects. It may cause
deterioration of quality, etc.
Stop operation and close the window
in storm or cyclone
Operation with windows opened may
cause wetting of indoor and soaking
of household furniture
Hold the plug by the head of the power
plug when taking it out
It may cause electric shock and damage
Turn o the main power switch when not
using the unit for a long time
It may cause failure of product or re and
explosion
Do not place obstacles around air-inlets
or inside of air-outlet
It may cause failure of appliance
or accident
Always insert the lters securely.
Clean lter once every two weeks
Operation without lters may cause
failure
Do not use strong detergent such
as wax or thinner - use a soft cloth
Appearance may be deteriorated due
to change of product colour or scratching
of its surface
Do not place heavy object on the power
cord and ensure that the cord is not
compressed
There is danger of re, explosion
or electric shock
Do not drink water drained from
air conditioner
It contains contaminants and could make
you sick
Use caution when unpacking and installing Sharp edges could cause injury
If water enters the unit, turn the unit o at
the power outlet and switch o the circuit
breaker. Isolate supply by taking the
power-plug out and contact a qualied
service technician
It could cause electric shock and damage
12 www.electrolux.com



3.
UNIT DESCRIPTION
Check all the accessories are included in the package and please refer to the installation
instructions for their usage.
1
2
5
6
3
10
11
12
13
9
4
7
8
Remote control
Signal receiver
Carrying handle (both sides)
Air intake
Room air outlet
Air exhaust
Power plug socket
Castor
Control panel
Power cord
Continuous drain outlet
Bottom drain outlet
Pump drain outlet
4.
ACCESSORIES INCLUDED
1
2
3
4
PARTS PARTS NAME: QUANTITY:
Adaptor A, Exhaust duct,
Adaptor B (at mouth),
Drain hose
Remote control
1 set
1 pc
1 set
Battery (R03P “AAA” 1.5V) 2 pcs
13ENGLISH
5.
INSTALLATION INSTRUCTIONS
5.1
Exhausting hot air
In the Cool Mode the appliance must be
placed close to a window or opening so
that the warm exhaust air can be ducted
outside. First position unit on a at oor
and make sure there’s a minimum of
50cm clearance around the unit, and is
within the vicinity of a single circuit outlet
power source.
1.
Extend either side of the hose (Fig. 1)
and screw the hose to adaptor A (Fig. 2).
3.
Install the adaptor A into the unit (Fig. 4).
Fig. 4
2.
Extend the other side of the hose and
screw it to adaptor B (Fig. 3).
)LJ
)LJ
)LJ
/RFN
6OLGHRQWR
The hose can be extended from
its original length of 38cm up to
150cm, but it is the best to keep
the length to minimum required.
Also make sure that the hose does
not have any sharp bends or sags.
(Fig. 6)
The adaptor A already be screwed
to the hose for this unit.
)LJ
4.
Ax the adaptor B into the window.
(Fig. 5)
14 www.electrolux.com
7.
OPERATING INSTRUCTIONS
Some of the following instructions
can only be used by using the
Control Panel.
It is not necessary to use the
drainage hose in the “cool” mode.
Cooling mode
Heating mode (on some models)
In this mode the exhaust adaptor hose
MUST be used.
In this mode the exhaust adaptor hose
MUST be used.
7.1
Usage of the Control Panel
1.
Press the “mode” button until the Cool
mode indicator is lit.
2.
Press the “fan speed” button to
choose the fan speed according
to the illumination of the fan speed
indicator. You can choose the
fan speed as following sequence:
“auto” → “hi” → “med” → “low” → “auto”.
3.
Press the “
” or “ ” button to choose
the temperature you want.
1.
Press the “mode” button until the “Heat”
indicator is lit.
2.
Press the “fan speed” button to
choose the fan speed according
to the illumination of the fan speed
indicator. You can choose the
fan speed as following sequence:
“auto” → “hi” → “med” → “low” → “auto”.
3.
Press the “
” or “ ” button to choose
the temperature you want.
4.
Connected drain hose. See 7.4
Drainage section.
6.
AIR CONDITIONER FEATURES
6.1
CONTROL PANEL
1
2
7
3
4
5
6
8
9
Displays temperature/time
Power ON/OFF
Sleep
Filter Reset
Fan Speed
Adjust Temperature or Timer
Mode Selection
Timer
Swing
Dry mode
Press the “mode” button until the Dry
mode indicator is lit. The screen displays
the room temperature.
At the same time, the “low” fan indicator
lights.
Note:
In this mode, fan speed cannot
be selected.
15ENGLISH
Fan mode
In this mode, there is no need to use the
exhaust hose or drainage hose.
1.
Press the “mode” button until
the Fan mode indicator is lit.
2.
Press the “Fan speed” button
to choose the desired fan speed.
3.
The fan will run at the selected speed
and the display will show the room
temperature.
Auto mode
Timer mode
How to delay startup
Always have the exhaust hose attached
in this mode.
When you set the air conditioner in Auto
mode, it will automatically select cooling,
heating (inapplicable for cooling only
models), or fan only operation depending
on what temperature you have selected and
the room temperature. The air conditioner
will control room temperature automatically
round the temperature point set by you.
Under AUTO mode, you can not select
the fan speed.
1. Press the “mode” button until the
“Auto mode” indicator lights.
After the “Auto mode” is selected the unit
will run automatically according to the
actual room air temperature.
The timer facilitates the user to delay the
unit startup or shutdown.
Plug in the unit, so the unit turns to standby.
Press the “timer” button, then the Timer
indicator will switch on and the number
of hours on the screen will show “0.0”.
Tap or hold the UP arrow
or the DOWN
arrow “
” to change delay start timer at
0.5 hour increments up to 10 hours, then
at 1 hour increments up to 24 hours. Press
the “timer” button again within 5 seconds,
you will quit the timer setting directly.
After 5 seconds, the timer function
is enabled, the display will show the
temperature back. The control will count
down the time remaining until startup.
The unit will start up in the mode
as previously set.
To cancel the setting, press the “timer”
button again will show the remain time and
press the button again to quit the function.
You can also cancel the setting by pressing
How to delay shutdown
You can delay shutdown when the unit
is on.
Press the “timer” button, then the Timer
indicator will switch on and the number
of hours on the screen will show “0.0”.
Tap or hold the UP arrow “
” or the
DOWN arrow “
” to change delay
stop timer at 0.5 hour increments up
to 10 hours, then at 1 hour increments
up to 24 hours. Press the “timer” button
again within 5 seconds, you will quit
the timer setting directly.
After 5 seconds, the timer function
is enabled, the display will show the
temperature back. The control will count
down the time remaining until shuts down.
To cancel the setting, press the “timer”
button again will show the remaing time and
press the button again to quit the function.
You can also cancel the setting by pressing
the “on/o” button. After cancel the setting,
the timer indicator will switch o.
Filter reset
Sleep mode
Active this feature will give you a
comfortable temperature and help
save energy.
Only when the unit is in Cool, Heat or auto
mode, you can press the “sleep” button to
make the unit run in Sleep mode.
Note: Please refer to page 17 for the
details about “Sleep” mode.
This feature is a reminder to clean the Air
Filter (See Care and Cleaning) for more
ecient operation.
The lter indicator will illuminate after
250 hours of operation. To reset after
cleaning the lter, press the “lter reset”
button, then the “lter” indicator will go o.
°F/°C function
Press the “
” and “ ” button the same
time for more than 3 seconds to switch
between degree Fahrenheit and degrees
Celsius. Under Dry/Fan mode, you can
not select °F/°C.
Press the “swing” button to enable louver
swing function, the louver on the top
panel will swing up and down.
Press this button again to disable the
louver swing function.
Louver Swing Function
Note:
In this mode, auto speed cannot
be selected.
the “on/o” button. After cancel the setting,
the timer indicator will switch o.
16 www.electrolux.com
8VHU
0D[P
5HPRWHFRQWURO
3RUWDEOH$&
TURNING THE UNIT ON
Remove the cover at the back of the
remote control.
Insert the provided batteries correctly
(see the instructions inside the battery
compartment).
Close up the cover.
To replace the old batteries (which have
been used up) with two new R03P “AAA”
1.5V batteries, repeat the steps above.
Battery Installation and Important
Instructions
How to Use the Remote Control
7.2
Remote Control
1
2
5
3
7
4
8
6
Remote Control screen
Temp/Timer setting button
On/O button
Mode button
Sleep button
Timer button
Swing button
Speed button
If the remote control unit is replaced or
discarded, the batteries must be removed
and disposed of in accordance with
local legislation as they do harm to the
environment.
Do not mix old and new batteries.
Do not mix alkaline, standard (carbon-
zinc) or rechargeable (nickel-cadmium)
batteries.
Do not dispose of batteries in re. Batteries
may explode or leak. If the remote control
is not used for a long time, remove the
batteries from the remote control.
The remote control must be handled with
extreme care. Do not drop it or expose it
to direct sunlight or sources of heat.
This device complies with Part 15 of the
FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful
interference, and (2) this device must
accept any interference received,
including interference that may cause
undesired operation.
Point the remote control at the location
of the signal receiver. The remote control
must be no more than 16 ft (5 meters)
away from the unit (without obstacles
between the remote control and the unit).
17ENGLISH
Plug in the unit, then press the “on/o”
button (when turned on, the unit will operate
as the last setting before shutdown.
To switch the unit o, press “on/o”
button again, then remove the plug.
Always switch the unit o by pressing the
“on/o” button and wait for few minutes
before removing the plug.
Press the “mode” button until the left side
of LCD screen displays “cool”.
Press the “fan speed” button to choose the
fan speed “auto”, “high”, “mid”, and “low”.
Press the “
” and “ ” button to choose
the temperature you want.
Press the “mode” button until the left side
of LCD screen displays “dry”.
At the same time, the “low” fan symbol
appears on the screen.
Note: In this mode, fan speed cannot
be selected.
Press the “mode” button until the left side
of LCD screen displays “heat”.
Press the “fan speed” button to choose the
fan speed “auto”, “high”, “mid”, and “low”.
Press the “
” and “ ” button to choose
the temperature you want.
Press the “mode” button until the upper
side of LCD screen displays “auto”.
Under AUTO mode, you can not select
the fan speed.
Press the “
” and “ ” button to choose
the temperature you want.
When the unit is in Cool, Heat or auto
mode, you can press the “sleep” button
to make the unit run in Sleep mode. In this
mode, the fan speed will be set as “auto”
automatically, which cannot be changed.
In Cool/Heat mode the selected
temperature will increase/decrease
by 1°C 30 minutes after the mode is
selected. The temperature will then
increase/decrease by another 1°C after
an additional 30 minutes. This new
temperature will be maintained for 7 hours
before it returns to the originally selected
temperature. This ends the “Sleep” mode
and the unit will shut down automatically.
Press the “mode” button until the left side
of LCD screen displays “fan”.
In this mode, you can select fan speed
“high”, “mid” or “low” by pressing the Fan
speed button and referring to the diagram.
Note: In this mode, the air exhaust hose
does not need to be connected.
Cool mode
Dry mode
Heat mode (For Heat & Cool models only)
AUTO mode
Sleep mode
Fan mode
18 www.electrolux.com
The “Sleep” mode program can be
cancelled at any time during operation by
pressing the “Sleep”, “mode” or “fan speed”
button.
Note: In Fan or Dry mode, Sleep mode
cannot be set.
Press the “swing” button to enable louver
swing function, and the upper side of
screen will display “
”. The louver
on the top panel will swing up and down.
Press this button again to disable the
louver swing function.
Louver Swing Function
°F/°C function
Timer mode
Press the “
” and “ ” button the same
time for more than 3 seconds to switch
between degree Fahrenheit and degrees
Celsius. Under Dry/Fan mode, you can
not select °F/°C.
How to delay startup
Plug in the unit, so the unit turns to
standby. Press the “timer” button, the
screen will display “timer”and “h”, and
the “on” will ashing.
Tap or hold the UP arrow “
” or the
DOWN arrow “
” to change delay start
timer at 0.5 hour increments up to
10 hours, then at 1 hour increments up to
24 hours. After 3 seconds, the setting will
be memorized. The control will count down
the time remaining until startup. You can
also press the “timer” button again directly
and the “on” will stop ashing immediately,
then the unit will start up in the mode as
previously set.
You can set up the mode and the unit will
start up as you preferred after “on” stop
ashing.
To cancel the setting, press the “timer”
button again.
19ENGLISH
NOTE:
Unscrew the drain cap of continuous
drain outlet(Fig.20).
Connect one end of the garden hose
(sold separately) or drain hose to the
drain outlet then lead the other end into
a drain that is lower than the unit(Fig.21).
Condensate may ow out after removing
the drain cap, if the unit is running in
Cool or Auto mode. When you want
to remove the garden hose, prepare
a drip tray (not supplied) to collect the
condensate from the drain outlet.
Please be sure that the height of the
drain and section of the drain hose
should not be higher than that of the
drain outlet, or the continous drainage
may not work properly.
During Cool or Auto mode, it is
recommended to disable continuous
drainage by replacing the drain cap to
the drain outlet, to reach the maximum
performance.
How to delay shutdown
You can delay shutdown when the unit is
on. Press the “timer” button, the screen
will display “timer” and “h”, and the “o”
will ashing.
Tap or hold the UP arrow
or the DOWN
arrow “
” to change delay stop timer at
0.5 hour increments up to 10 hours, then
at 1 hour increments up to 24 hours. After
3 seconds, the setting will be memorized,
and the display will show the time
remaining until the unit shuts down. You
can also press the “timer” button again
directly and the “o” will stop ashing
immediately.
To cancel the setting, press the “timer”
button again.
If the display reads “AS”, “CS” and
“ES”, the temperature sensor has failed.
Contact your Authorized Electrolux
Service Center.
If the display reads “L3”, the condenser
DC fan motor has failed. Contact your
Authorized Electrolux Service Center.
If the display reads “E4”, the communication
between display PCB and main control
PCB is faulty. Contact your Authorized
Electrolux Service Center.
If the display reads “P1”, bottom tray is
full. Carefully move the unit to a drain
location, remove the bottom drain plug
and let the water drain away. Restart the
machine until the “P1” symbol disappears.
If error repeats, call for service.
7.3
Fault code
Continuous Drainage
During the DRY mode or heat pump
model, you will need a garden hose
(sold separately) or drain hose to drain
the condensate from the unit.
Follow the steps below:
7.4
Drainage instruction
Fig. 20
Drain cap
for Dry mode
Drain cap
for Heat Pump mode
Garden hose
Drain hose
Fig. 21
20 www.electrolux.com
NOTE: To ensure all condensate residue
has been removed, tilt the unit by lifting
it slightly upwards from the front until no
more condensate comes out from the
drain outlet.
Emptying the condensate residue inside
the unit during winter storage.
Put a drip tray (not supplied) under
bottom drain outlet, then pull out the
drain cap to allow the condensate
to ow into the drip tray.
)LJ
)LJ
Bottom
Drain Outlet
Drip cap
Drip tray
1
2
Replace the drain cap to the continuous
drain outlet when no condensate ows out.
Put the drip tray under the bottom drain
outlet, then remove the rubber stopper from
the drain outlet, to allow the condensate to
ow into the drip tray. If your drip tray can’t
hold all the condensate, a number of lls
will be needed.
Replace the drain cap to the bottom drain
outlet when no condensate ows out.
8.
CARE & CLEANING
Clean your air conditioner occasionally
to keep it looking new. Be sure to unplug
the unit before cleaning to prevent shock
or re hazards.
The cabinet and front may be dusted with
an oil-free cloth or washed with a cloth
dampened in a solution of warm water
and mild liquid dishwashing detergent.
Never use harsh cleaners, wax or polish
on the cabinet front.
Be sure to wring excess water from the
cloth before wiping around the controls.
Excess water in or around the controls
may cause damage to the air conditioner.
8.1
Cleaning the unit
1.
Removed the air lter as shown the
below gure.
To keep your air conditioner working
eciently, you should clean the lters
every two weeks of operation.
Take out the upper air lter and the
lower air lter.
8.2
Cleaning the lters
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152

Electrolux EXP34U338CW Bruksanvisning

Typ
Bruksanvisning