Safety information ............................................................................................................................... 4
Technical information ........................................................................................................................ 10
Type plate.........................................................................................................................................10
Energy class .....................................................................................................................................10
Unit description ..................................................................................................................................11
Accessories included ........................................................................................................................ 11
Installation instructions .................................................................................................................... 12
Positioning of the unit ......................................................................................................................12
Installation .......................................................................................................................................13
Installation of window slider kit........................................................................................................13
Operating instructions .......................................................................................................................14
Important before using the AC ..........................................................................................................14
Control panel ................................................................................................................................... 15
Operating AC from the control panel .............................................................................................15
Turning the AC on ..........................................................................................................................15
Control panel operating instructions ................................................................................................16
Cool mode ................................................................................................................................... 16
Fan mode ......................................................................................................................................16
Dry mode ......................................................................................................................................16
Timer mode ...................................................................................................................................16
Self-diagnosis ..................................................................................................................................17
Operating instruction for remote control ..........................................................................................18
Inserting or replacing the batteries ...............................................................................................18
Cool mode ....................................................................................................................................19
Fan mode ......................................................................................................................................19
Dry mode ......................................................................................................................................19
Auto mode ....................................................................................................................................19
Sleep mode .................................................................................................................................. 20
Timer mode .................................................................................................................................. 20
Change the unit of temperature ................................................................................................... 20
Maintenance instructions .................................................................................................................. 21
Water drainage method.......................................................................................................................21
Manual draining ............................................................................................................................21
Continuous draining .....................................................................................................................21
Cleaning and maintenance .............................................................................................................. 22
Cleaning the cabinet .................................................................................................................... 22
Cleaning the air filter ................................................................................................................... 22
Start-end of season maintenance .................................................................................................... 22
Check in the beginning of season operations ............................................................................... 22
End of of season operations ........................................................................................................ 22
Troubleshooting ................................................................................................................................23
Recycling ...........................................................................................................................................23
Notes .................................................................................................................................................45
4 (48)
Please be sure to read this user manual carefully before using the Altech Portabel AC (in this instruction also called AC,
unit or appliance). Any questions, please contact the professional service for help.
SAFETY INFORMATION
2 3
Motor kW 3 x 400 V
1,5 mm22,5 mm24,0 mm26,0 mm2
0,55 246 m
0,75 200 m 333 m
1,10 146 m 244 m 390 m
1,50 109 m 180 m 290 m 435 m
Motor kW 3 x 400 V
Amp
0,55 1,7
0,75 2,2
1,10 3,0
1,50 4,0
Kopplingsschema för djupbrunnspumpar
UNDERHÅLL
Djupbrunnspumpen är i sig själv underhållsfri. Ett
normalt slitage vid pumpning av rent vatten märks
först efter mycket lång tid i drift, dvs pumpen förlorar
kapacitet. Dock skall anläggningens elektriska del un-
derkastas en fortlöpande kontroll av tex nätspänning.
strömförbrukning, manöverorganens elektriska och
mekaniska funktion. fukt, oxidation, brända kontakter
etc. Det är också lämpligt att fortlöpande kontrol-
lera pumpmotorns lindningsvärden. Avvikelser från
föreskrivna lindningsvärden tyder på driftstörningar.
Pumpar som ej är i drift under längre perioder kan utan
problem förbli installerade.
En kortare drift c:a 5–10 minuter per månad förhindrar
att pumpens roterande system fastnar pga. avlagringar.
Ej installerade pumpar skall lagras i sval lokal och verti-
kalt. Före återinstallation, kontrollera motorns fyllning
respektive att det roterande systemet ej fastnat. En rätt
installerad undervattenspump har alla förutsättningar
att ge en lång och säker drift förutsatt att den erhåller:
• rättnätspänning
• rentkalltvatten
• rättstartfrekvens
Det är viktigt för pumpen och anläggningens funktion,
att regelbundet eller minst en gång per år kontrollera
luftmängden i hydroforen. Observera att antalet starter
per timma ej får överskrida 20 st. Den situationen
kan uppstå om hydroforen som används har felaktig
luftmängd. Är anläggningen monterad med membran-
hydrofor skall lufttrycket vara 0,2 bar under pumpens
starttryck. Om tex. starttrycket är 1,5 bar så skall luft-
trycket vara 1,3 bar. Innan pump-anläggningen startas,
kontrollera dessa värden. Vid kontroll av membranhy-
droforens lufttryck skall den alltid vara tom på vatten.
Luftventilen på tanktoppen är av samma typ som finns
på bildäck. Tryckmätning, påfyllning samt avtappning
av luft sker på samma sätt som på ett vanligt bildäck.
Djupbrunnspump: Maximal kabellängd i
meter Avstånd pumpmotor – mätarcentral
Kabeldimensionering enligt tabellerna är vår generella
rekommendation för att garantera djupbrunnspumpens
goda funktion under normala förhållanden. Avvikande
driftsförhållanden som spänningsfall på elnätet, drift
via elverk, varvtalsreglering med frekvensomriktare m
m kan medföra annan dimensionering Lokala stark-
strömsföreskrifter skall beaktas.
REKOMMENDERAD
UNDERVATTENSKABEL
H07RN-F
Djupbrunnspump.
Effekt och märkström
Säkerhetsinstruktion
Installation och drift av roterande maskiner och ap-
parater kan vid icke fackmässig och oriktig hantering
ge upphov till omfattande person- och materialskador.
Bidra till en säker arbetsmiljö samt en ökad livslängd
hos den levererade materielen genom att observera
följande varningssymboler.
Elektrisk anslutning får enbart göras av
behörig elektriker i enlighet med Stark-
strömsföreskrifterna.
Pumpa aldrig andra vätskor än de pumpar-
na är avsedda för. Detta gäller i synnerhet
eldfarliga, explosiva eller frätande vätskor.
Överskrid aldrig maximalvärdena för tryck
och temperatur. Trycksatta rörsystem skall
alltid förses med godkänd säkerhetsventil.
Vid arbete på pumpen (apparaten) skall
alltid arbetsskyddsbrytaren vara frånsla-
gen.
Läs alltid den medlevererade montage-
föreskriften. Om den har förkommit eller
förstörts, kontakta oss.
Tryckkärl monterade i pumpanläggningar
och rörsystem skall vara typgodkända av
ackrediterat kontrollorgan i enlighet med
Arbetsmiljölagen 3 kapitlet , 8 paragra-
fen. Typgodkännandenumret skall vara
angivet på tryckkärlet och leverantören är
på anmodan skyldig att överlämna giltigt
typgodkännandecertifikat.
FARA
FARA
VARNING
VARNING
WARNING!
System contains refrigerant under very high pressure. The system must be serviced by qualified persons only.
2 3
Motor kW 3 x 400 V
1,5 mm22,5 mm24,0 mm26,0 mm2
0,55 246 m
0,75 200 m 333 m
1,10 146 m 244 m 390 m
1,50 109 m 180 m 290 m 435 m
Motor kW 3 x 400 V
Amp
0,55 1,7
0,75 2,2
1,10 3,0
1,50 4,0
Kopplingsschema för djupbrunnspumpar
UNDERHÅLL
Djupbrunnspumpen är i sig själv underhållsfri. Ett
normalt slitage vid pumpning av rent vatten märks
först efter mycket lång tid i drift, dvs pumpen förlorar
kapacitet. Dock skall anläggningens elektriska del un-
derkastas en fortlöpande kontroll av tex nätspänning.
strömförbrukning, manöverorganens elektriska och
mekaniska funktion. fukt, oxidation, brända kontakter
etc. Det är också lämpligt att fortlöpande kontrol-
lera pumpmotorns lindningsvärden. Avvikelser från
föreskrivna lindningsvärden tyder på driftstörningar.
Pumpar som ej är i drift under längre perioder kan utan
problem förbli installerade.
En kortare drift c:a 5–10 minuter per månad förhindrar
att pumpens roterande system fastnar pga. avlagringar.
Ej installerade pumpar skall lagras i sval lokal och verti-
kalt. Före återinstallation, kontrollera motorns fyllning
respektive att det roterande systemet ej fastnat. En rätt
installerad undervattenspump har alla förutsättningar
att ge en lång och säker drift förutsatt att den erhåller:
• rättnätspänning
• rentkalltvatten
• rättstartfrekvens
Det är viktigt för pumpen och anläggningens funktion,
att regelbundet eller minst en gång per år kontrollera
luftmängden i hydroforen. Observera att antalet starter
per timma ej får överskrida 20 st. Den situationen
kan uppstå om hydroforen som används har felaktig
luftmängd. Är anläggningen monterad med membran-
hydrofor skall lufttrycket vara 0,2 bar under pumpens
starttryck. Om tex. starttrycket är 1,5 bar så skall luft-
trycket vara 1,3 bar. Innan pump-anläggningen startas,
kontrollera dessa värden. Vid kontroll av membranhy-
droforens lufttryck skall den alltid vara tom på vatten.
Luftventilen på tanktoppen är av samma typ som finns
på bildäck. Tryckmätning, påfyllning samt avtappning
av luft sker på samma sätt som på ett vanligt bildäck.
Djupbrunnspump: Maximal kabellängd i
meter Avstånd pumpmotor – mätarcentral
Kabeldimensionering enligt tabellerna är vår generella
rekommendation för att garantera djupbrunnspumpens
goda funktion under normala förhållanden. Avvikande
driftsförhållanden som spänningsfall på elnätet, drift
via elverk, varvtalsreglering med frekvensomriktare m
m kan medföra annan dimensionering Lokala stark-
strömsföreskrifter skall beaktas.
REKOMMENDERAD
UNDERVATTENSKABEL
H07RN-F
Djupbrunnspump.
Effekt och märkström
Säkerhetsinstruktion
Installation och drift av roterande maskiner och ap-
parater kan vid icke fackmässig och oriktig hantering
ge upphov till omfattande person- och materialskador.
Bidra till en säker arbetsmiljö samt en ökad livslängd
hos den levererade materielen genom att observera
följande varningssymboler.
Elektrisk anslutning får enbart göras av
behörig elektriker i enlighet med Stark-
strömsföreskrifterna.
Pumpa aldrig andra vätskor än de pumpar-
na är avsedda för. Detta gäller i synnerhet
eldfarliga, explosiva eller frätande vätskor.
Överskrid aldrig maximalvärdena för tryck
och temperatur. Trycksatta rörsystem skall
alltid förses med godkänd säkerhetsventil.
Vid arbete på pumpen (apparaten) skall
alltid arbetsskyddsbrytaren vara frånsla-
gen.
Läs alltid den medlevererade montage-
föreskriften. Om den har förkommit eller
förstörts, kontakta oss.
Tryckkärl monterade i pumpanläggningar
och rörsystem skall vara typgodkända av
ackrediterat kontrollorgan i enlighet med
Arbetsmiljölagen 3 kapitlet , 8 paragra-
fen. Typgodkännandenumret skall vara
angivet på tryckkärlet och leverantören är
på anmodan skyldig att överlämna giltigt
typgodkännandecertifikat.
FARA
FARA
VARNING
VARNING
WARNING!
According to the EN standard:
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in
order to avoid a hazard.
According the IEC standard:
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabi
lities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of
the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
Disconnect the appliance from its power source during service and when replacing parts and cleaning.
The appliance shall be installed in accordance with national wiring regulations.
The appliance shall not be installed in the laundry.
Please note: Check the type plate for the type of refrigerant gas used in your appliance.
Specific information regarding appliances with refrigerant gas:
R410A, R134a, R290 is a refrigerant that complies with European ecological standards; nevertheless, it is recommended
not to pierce the cooling circuit of the machine. At the end of its useful life, deliver the appliance to a special waste
collection center for disposal.
This hermetically sealed system contains fluorinated greenhouse gases.
ENVIRONMENTAL INFORMATION: This unit contains fluorinated greenhouse gases covered by the Kyoto Protocol.
The maintenance and disposal operations must be carried out by qualified personnel only. (For more details on the refri-
gerant, see back cover). GWP (Global Warming Potential): R410A:2008, R134a, 1430, R290:3.
Do not use this unit for functions other than those described in this instruction manual.
If the power cord becomes worn or damaged, the cord should only be replaced by a qualified service technician using
genuine replacement parts.
Make sure the plug is plugged firm and completely into the outlet. It can result in the risk of electric shock or fire.
Do not plug other appliances into the same outlet, it can result in the risk of electric shock.
Do not disassemble or modify the appliance or the power cord, it can result in the risk of electric shock or fire. All other
services should be referred to a qualified technician.
Do not place the power cord or appliance near a heater, radiator, or other heat sources. It can result in the risk of electric
shock or fire.
This unit is equipped with a cord that has an earthed wire connected to an earthed pin or grounding tab. The plug must
be plugged into a socket that is properly installed and earthed. Do not under any circumstances cut or remove earthed
pin or grounding tab from this plug.
The unit should be used or stored in such a way that it is protected from moisture e.g. condensation, splashed water,
etc. Unplug unit immediately if this occurs.
Always transport your appliance in a vertical position and place on a stable, level surface during use. If the unit is trans-
ported laying on its side it should be stood up and left unplugged for 6 hours.
Always use the switch on the control panel or remote control to turn the unit off, and do not start or stop operating by
plugging in or unplugging the power cord. It can result in the risk of electric shock.
Do not touch the buttons on the control panel with your wet and damp fingers.
Do not use hazardous chemicals to clean or come into contact with the unit. To prevent damage to the surface finish,
use only a soft cloth to the clean appliance. Do not use wax, thinner or a strong detergent. Do not use the unit in the
5 (48)
presence of inflammable substance or vapour such as alcohol, insecticides, gasoline, etc.
If the appliance is making unusual sounds or is emitting smoke or an unusual odor, unplug it immediately.
Do not clean the unit with water. Water can enter the unit and damage the insulation, creating a shock hazard. If water
enters the unit, unplug it immediately and contact the Customer Service.
Utilize two or more people to lift and install the unit.
Always grasp the plug when plugging in or unplugging the appliance. Never unplug by pulling on the cord. It can result
in the risk of electrical shock and damage.
Install the appliance on a sturdy, level floor capable of supporting up to 50 kg. Installation on a weak or unlevel floor can
result in the risk for property damage and personal injury.
2 3
Motor kW 3 x 400 V
1,5 mm22,5 mm24,0 mm26,0 mm2
0,55 246 m
0,75 200 m 333 m
1,10 146 m 244 m 390 m
1,50 109 m 180 m 290 m 435 m
Motor kW 3 x 400 V
Amp
0,55 1,7
0,75 2,2
1,10 3,0
1,50 4,0
Kopplingsschema för djupbrunnspumpar
UNDERHÅLL
Djupbrunnspumpen är i sig själv underhållsfri. Ett
normalt slitage vid pumpning av rent vatten märks
först efter mycket lång tid i drift, dvs pumpen förlorar
kapacitet. Dock skall anläggningens elektriska del un-
derkastas en fortlöpande kontroll av tex nätspänning.
strömförbrukning, manöverorganens elektriska och
mekaniska funktion. fukt, oxidation, brända kontakter
etc. Det är också lämpligt att fortlöpande kontrol-
lera pumpmotorns lindningsvärden. Avvikelser från
föreskrivna lindningsvärden tyder på driftstörningar.
Pumpar som ej är i drift under längre perioder kan utan
problem förbli installerade.
En kortare drift c:a 5–10 minuter per månad förhindrar
att pumpens roterande system fastnar pga. avlagringar.
Ej installerade pumpar skall lagras i sval lokal och verti-
kalt. Före återinstallation, kontrollera motorns fyllning
respektive att det roterande systemet ej fastnat. En rätt
installerad undervattenspump har alla förutsättningar
att ge en lång och säker drift förutsatt att den erhåller:
• rättnätspänning
• rentkalltvatten
• rättstartfrekvens
Det är viktigt för pumpen och anläggningens funktion,
att regelbundet eller minst en gång per år kontrollera
luftmängden i hydroforen. Observera att antalet starter
per timma ej får överskrida 20 st. Den situationen
kan uppstå om hydroforen som används har felaktig
luftmängd. Är anläggningen monterad med membran-
hydrofor skall lufttrycket vara 0,2 bar under pumpens
starttryck. Om tex. starttrycket är 1,5 bar så skall luft-
trycket vara 1,3 bar. Innan pump-anläggningen startas,
kontrollera dessa värden. Vid kontroll av membranhy-
droforens lufttryck skall den alltid vara tom på vatten.
Luftventilen på tanktoppen är av samma typ som finns
på bildäck. Tryckmätning, påfyllning samt avtappning
av luft sker på samma sätt som på ett vanligt bildäck.
Djupbrunnspump: Maximal kabellängd i
meter Avstånd pumpmotor – mätarcentral
Kabeldimensionering enligt tabellerna är vår generella
rekommendation för att garantera djupbrunnspumpens
goda funktion under normala förhållanden. Avvikande
driftsförhållanden som spänningsfall på elnätet, drift
via elverk, varvtalsreglering med frekvensomriktare m
m kan medföra annan dimensionering Lokala stark-
strömsföreskrifter skall beaktas.
REKOMMENDERAD
UNDERVATTENSKABEL
H07RN-F
Djupbrunnspump.
Effekt och märkström
Säkerhetsinstruktion
Installation och drift av roterande maskiner och ap-
parater kan vid icke fackmässig och oriktig hantering
ge upphov till omfattande person- och materialskador.
Bidra till en säker arbetsmiljö samt en ökad livslängd
hos den levererade materielen genom att observera
följande varningssymboler.
Elektrisk anslutning får enbart göras av
behörig elektriker i enlighet med Stark-
strömsföreskrifterna.
Pumpa aldrig andra vätskor än de pumpar-
na är avsedda för. Detta gäller i synnerhet
eldfarliga, explosiva eller frätande vätskor.
Överskrid aldrig maximalvärdena för tryck
och temperatur. Trycksatta rörsystem skall
alltid förses med godkänd säkerhetsventil.
Vid arbete på pumpen (apparaten) skall
alltid arbetsskyddsbrytaren vara frånsla-
gen.
Läs alltid den medlevererade montage-
föreskriften. Om den har förkommit eller
förstörts, kontakta oss.
Tryckkärl monterade i pumpanläggningar
och rörsystem skall vara typgodkända av
ackrediterat kontrollorgan i enlighet med
Arbetsmiljölagen 3 kapitlet , 8 paragra-
fen. Typgodkännandenumret skall vara
angivet på tryckkärlet och leverantören är
på anmodan skyldig att överlämna giltigt
typgodkännandecertifikat.
FARA
FARA
VARNING
VARNING
WARNING!
Before plugging in the appliance into the mains socket, check below. Failure to follow these important safety instructions
absolves the manufacturer of all liability.
The mains power supply corresponds to the value indicated on the type plate on the back of the appliance.
The power socket and electrical circuit are adequate for the appliance.
The mains socket matches the plug. If this is not the case, have the plug replaced.
The mains socket is adequately earthed.
2 3
Motor kW 3 x 400 V
1,5 mm22,5 mm24,0 mm26,0 mm2
0,55 246 m
0,75 200 m 333 m
1,10 146 m 244 m 390 m
1,50 109 m 180 m 290 m 435 m
Motor kW 3 x 400 V
Amp
0,55 1,7
0,75 2,2
1,10 3,0
1,50 4,0
Kopplingsschema för djupbrunnspumpar
UNDERHÅLL
Djupbrunnspumpen är i sig själv underhållsfri. Ett
normalt slitage vid pumpning av rent vatten märks
först efter mycket lång tid i drift, dvs pumpen förlorar
kapacitet. Dock skall anläggningens elektriska del un-
derkastas en fortlöpande kontroll av tex nätspänning.
strömförbrukning, manöverorganens elektriska och
mekaniska funktion. fukt, oxidation, brända kontakter
etc. Det är också lämpligt att fortlöpande kontrol-
lera pumpmotorns lindningsvärden. Avvikelser från
föreskrivna lindningsvärden tyder på driftstörningar.
Pumpar som ej är i drift under längre perioder kan utan
problem förbli installerade.
En kortare drift c:a 5–10 minuter per månad förhindrar
att pumpens roterande system fastnar pga. avlagringar.
Ej installerade pumpar skall lagras i sval lokal och verti-
kalt. Före återinstallation, kontrollera motorns fyllning
respektive att det roterande systemet ej fastnat. En rätt
installerad undervattenspump har alla förutsättningar
att ge en lång och säker drift förutsatt att den erhåller:
• rättnätspänning
• rentkalltvatten
• rättstartfrekvens
Det är viktigt för pumpen och anläggningens funktion,
att regelbundet eller minst en gång per år kontrollera
luftmängden i hydroforen. Observera att antalet starter
per timma ej får överskrida 20 st. Den situationen
kan uppstå om hydroforen som används har felaktig
luftmängd. Är anläggningen monterad med membran-
hydrofor skall lufttrycket vara 0,2 bar under pumpens
starttryck. Om tex. starttrycket är 1,5 bar så skall luft-
trycket vara 1,3 bar. Innan pump-anläggningen startas,
kontrollera dessa värden. Vid kontroll av membranhy-
droforens lufttryck skall den alltid vara tom på vatten.
Luftventilen på tanktoppen är av samma typ som finns
på bildäck. Tryckmätning, påfyllning samt avtappning
av luft sker på samma sätt som på ett vanligt bildäck.
Djupbrunnspump: Maximal kabellängd i
meter Avstånd pumpmotor – mätarcentral
Kabeldimensionering enligt tabellerna är vår generella
rekommendation för att garantera djupbrunnspumpens
goda funktion under normala förhållanden. Avvikande
driftsförhållanden som spänningsfall på elnätet, drift
via elverk, varvtalsreglering med frekvensomriktare m
m kan medföra annan dimensionering Lokala stark-
strömsföreskrifter skall beaktas.
REKOMMENDERAD
UNDERVATTENSKABEL
H07RN-F
Djupbrunnspump.
Effekt och märkström
Säkerhetsinstruktion
Installation och drift av roterande maskiner och ap-
parater kan vid icke fackmässig och oriktig hantering
ge upphov till omfattande person- och materialskador.
Bidra till en säker arbetsmiljö samt en ökad livslängd
hos den levererade materielen genom att observera
följande varningssymboler.
Elektrisk anslutning får enbart göras av
behörig elektriker i enlighet med Stark-
strömsföreskrifterna.
Pumpa aldrig andra vätskor än de pumpar-
na är avsedda för. Detta gäller i synnerhet
eldfarliga, explosiva eller frätande vätskor.
Överskrid aldrig maximalvärdena för tryck
och temperatur. Trycksatta rörsystem skall
alltid förses med godkänd säkerhetsventil.
Vid arbete på pumpen (apparaten) skall
alltid arbetsskyddsbrytaren vara frånsla-
gen.
Läs alltid den medlevererade montage-
föreskriften. Om den har förkommit eller
förstörts, kontakta oss.
Tryckkärl monterade i pumpanläggningar
och rörsystem skall vara typgodkända av
ackrediterat kontrollorgan i enlighet med
Arbetsmiljölagen 3 kapitlet , 8 paragra-
fen. Typgodkännandenumret skall vara
angivet på tryckkärlet och leverantören är
på anmodan skyldig att överlämna giltigt
typgodkännandecertifikat.
FARA
FARA
VARNING
VARNING
WARNING!
Important regarding grounding method.
This product has a factory equipped power supply cord that has a three-pronged grounded plug. It must be plugged
into a mating grounding type receptacle in accordance with the National Electrical Code and applicable local codes and
ordinances. If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of the custo-
mer to exchange the existing receptacle in accordance with the National Electrical Code and applicable local codes and
ordinances. The third ground prong should not, under any circumstances, be cut or removed. Never use the cord, the plug
or the appliance when they show any sign of damage. Do not use your appliance with an extension cord unless it has been
checked and tested by a qualified electrical supplier. Improper connection of the grounding plug can result in risk of fire,
electrical shock and/or injury to persons associated with the appliance. Check with a qualified service representative if in
doubt that the appliance is properly grounded.
2 3
Motor kW 3 x 400 V
1,5 mm22,5 mm24,0 mm26,0 mm2
0,55 246 m
0,75 200 m 333 m
1,10 146 m 244 m 390 m
1,50 109 m 180 m 290 m 435 m
Motor kW 3 x 400 V
Amp
0,55 1,7
0,75 2,2
1,10 3,0
1,50 4,0
Kopplingsschema för djupbrunnspumpar
UNDERHÅLL
Djupbrunnspumpen är i sig själv underhållsfri. Ett
normalt slitage vid pumpning av rent vatten märks
först efter mycket lång tid i drift, dvs pumpen förlorar
kapacitet. Dock skall anläggningens elektriska del un-
derkastas en fortlöpande kontroll av tex nätspänning.
strömförbrukning, manöverorganens elektriska och
mekaniska funktion. fukt, oxidation, brända kontakter
etc. Det är också lämpligt att fortlöpande kontrol-
lera pumpmotorns lindningsvärden. Avvikelser från
föreskrivna lindningsvärden tyder på driftstörningar.
Pumpar som ej är i drift under längre perioder kan utan
problem förbli installerade.
En kortare drift c:a 5–10 minuter per månad förhindrar
att pumpens roterande system fastnar pga. avlagringar.
Ej installerade pumpar skall lagras i sval lokal och verti-
kalt. Före återinstallation, kontrollera motorns fyllning
respektive att det roterande systemet ej fastnat. En rätt
installerad undervattenspump har alla förutsättningar
att ge en lång och säker drift förutsatt att den erhåller:
• rättnätspänning
• rentkalltvatten
• rättstartfrekvens
Det är viktigt för pumpen och anläggningens funktion,
att regelbundet eller minst en gång per år kontrollera
luftmängden i hydroforen. Observera att antalet starter
per timma ej får överskrida 20 st. Den situationen
kan uppstå om hydroforen som används har felaktig
luftmängd. Är anläggningen monterad med membran-
hydrofor skall lufttrycket vara 0,2 bar under pumpens
starttryck. Om tex. starttrycket är 1,5 bar så skall luft-
trycket vara 1,3 bar. Innan pump-anläggningen startas,
kontrollera dessa värden. Vid kontroll av membranhy-
droforens lufttryck skall den alltid vara tom på vatten.
Luftventilen på tanktoppen är av samma typ som finns
på bildäck. Tryckmätning, påfyllning samt avtappning
av luft sker på samma sätt som på ett vanligt bildäck.
Djupbrunnspump: Maximal kabellängd i
meter Avstånd pumpmotor – mätarcentral
Kabeldimensionering enligt tabellerna är vår generella
rekommendation för att garantera djupbrunnspumpens
goda funktion under normala förhållanden. Avvikande
driftsförhållanden som spänningsfall på elnätet, drift
via elverk, varvtalsreglering med frekvensomriktare m
m kan medföra annan dimensionering Lokala stark-
strömsföreskrifter skall beaktas.
REKOMMENDERAD
UNDERVATTENSKABEL
H07RN-F
Djupbrunnspump.
Effekt och märkström
Säkerhetsinstruktion
Installation och drift av roterande maskiner och ap-
parater kan vid icke fackmässig och oriktig hantering
ge upphov till omfattande person- och materialskador.
Bidra till en säker arbetsmiljö samt en ökad livslängd
hos den levererade materielen genom att observera
följande varningssymboler.
Elektrisk anslutning får enbart göras av
behörig elektriker i enlighet med Stark-
strömsföreskrifterna.
Pumpa aldrig andra vätskor än de pumpar-
na är avsedda för. Detta gäller i synnerhet
eldfarliga, explosiva eller frätande vätskor.
Överskrid aldrig maximalvärdena för tryck
och temperatur. Trycksatta rörsystem skall
alltid förses med godkänd säkerhetsventil.
Vid arbete på pumpen (apparaten) skall
alltid arbetsskyddsbrytaren vara frånsla-
gen.
Läs alltid den medlevererade montage-
föreskriften. Om den har förkommit eller
förstörts, kontakta oss.
Tryckkärl monterade i pumpanläggningar
och rörsystem skall vara typgodkända av
ackrediterat kontrollorgan i enlighet med
Arbetsmiljölagen 3 kapitlet , 8 paragra-
fen. Typgodkännandenumret skall vara
angivet på tryckkärlet och leverantören är
på anmodan skyldig att överlämna giltigt
typgodkännandecertifikat.
FARA
FARA
VARNING
VARNING
WARNING!
Specific information regarding appliances with R290/R32 refrigerant gas
Thoroughly read all of the warnings.
When defrosting and cleaning the appliance, do not use any tools or other than those recommended by the manufacturing
company.
The appliance must be placed in an area without any continuous sources of ignition (for example: open flames, gas or
electrical appliances in operations).
To not puncture and do not burn.
Refrigerant gases can be odorless.
The appliance must be installed, used and stored in an area that is greater than 13 m2.
R290/R32 is a refrigerant gas that complies with the European directives on the environment. Do not puncture any part
of the refrigerant circuit.
If the appliance is installed, operated or stored in a non-ventilated area, the room must be designed to prevent the
accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by
electric heaters, stoves, or other sources of ignition.
The appliance must be stored in such a way as to prevent mechanical failure.
Individuals who operate or work on the refrigerant circuit mas have the appropriate certification issued by an accredited
organization that ensures competence in handling refrigerants according to a specific evaluation recognized by associa-
tions in the industry.
Repairs must be performed based on the recommendations from the manufacturing company.
Maintenance and repairs that require the assistance of other qualified personnel must be performed under the supervi-
sion of an individual specified in the use of and individual specified in the use of flammable refrigerants.
Do not use means to accelerate defrosting process or to clean, other than those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an
operating gas appliance or an operating electric heater.).
Do not pierce or burn.
6 (48)
Be aware that the refrigerants may be odorless.
Compliance with national gas regulations shall be observed.
Keep ventilation openings clear of obstruction.
The appliance shall be stored so as to prevent mechanical damage from occurring.
A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area
as specified for operation.
Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate
from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in
accordance with an industry recognized assessment specification.
Servicing shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of
the person competent in the use of flammable refrigerants.
Appliance should be installed, operated and store in a room with a floor area larger than 13 m2.
1. TRANSPORT OF EQUIPMENT CONTAINING FLAMMABLE REFRIGERANTS
Compliance with the transport regulations.
2. MARKING OF EQUIPMENT USING SIGNS
Compliance with local regulations.
3. DISPOSAL OF EQUIPMENT USING FLAMMABLE REFRIGERANTS
Compliance with national regulations.
4. STORAGE OF EQUIPMENT/APPLIANCES
The storage of equipment should be in accordance with the manufacturer’s instructions.
5. STORAGE OF PACKED (UNSOLD) EQUIPMENT
Storage package protection should be constructed such that the mechanical damage to the equipment inside the package
will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored to-
gether will be determined by local regulations.
6. INFORMATION ON SERVICING
1) Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk
of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to
conducting work on the system.
2) Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapour being
present while the work is being performed.
3) General work area
All maintenance staff and others working in the local area shall be instructed on the nature work being carried out. Work
in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions
within the area have been made safe by control of flammable material.
4) Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware
of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flamma-
ble refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
5) Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing
equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
7 (48)
6) No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or
has contained flammable refrigerant shall use any sources of ignition in such manner that it may lead to the risk for fire or
explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of in-
stallation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding
space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable
hazards or ignition risks. “No Smoking” signs shall be displayed.
7) Ventilated area
Ensure that the area is not open or that it is adequately ventilated before breaking into the system or conducting any hot
work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely
disperse any released refrigerant and preferably expel it externally into the atmosphere.
8) Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose and the correct specification. At all times
the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical
department for assistance. The following checks shall be applied to installations using flammable refrigerants:
- The charge size is in accordance with the room size within which the refrigerant containing parts are installed.
- The ventilation machinery and outlets are operating adequately and are not obstructed.
- If an indirect refrigerant circuit is being used, the secondary circuit shall be checked for the presence of refrigerant.
- Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected.
- Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance
which may corrode refrigerant containing components, unless the components are constructed of materials which are
inherently resistant to being corroded or are suitably protected against being so corroded.
9) Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and component inspection procedu-
res. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is sa-
tisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate
temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial
safety checks shall include:
That the capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking.
That there no live electrical components and wiring are exposed while charging, recovering or purging the system.
That there is continuity of earth bonding.
7. REPAIRS TO SEALED COMPONENTS
1) During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked
upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment
during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of
a potentially hazardous situation.
2) Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not
altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of
connections, terminals not made to original specification, damage to seals, incorrect fittings of glands, etc. Ensure that
the apparatus is mounted securely. Ensure that seals or sealing materials have not degraded such that they no longer
serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with
the manufacturer’s specifications.
Note! The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe
components do not have to be isolated prior to working on them.
8. REPAIR TO INTRINSICALLY SAFE COMPONENTS
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the
permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that
can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating.
Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in
the atmosphere from a leak.
9. CABLING
Check that the cabling will not be subjected to wear, corrosion, excessive pressure, vibration, sharp edges or any other ad-
verse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources
such as compressors or fans.
8 (48)
10. DETECTION OF FLAMMABLE REFRIGERANTS
Under no circumstances shall potential sources of ignition be used in the searching for detection or refrigerant leaks.
A halide torch (or any other detector using a naked flame) shall not be used.
11. LEAK DETECTION METHODS
The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic
leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-
calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential
source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL
of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maxi-
mum) is confirmed. Leak detection fluids are suitable for use with most refrigerants, but the use of detergents containing
chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is sus-
pected, all naked flames shall be removed/extinguished. If a leakage of refrigerant is found which requires brazing, all of
the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote
from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system before and during the brazing process.
12. REMOVAL AND EVACUATION
When breaking into the refrigerant circuit to make repairs – or for any other purpose – conventional procedures shall be
used. However, it is important that the best practice is followed since flammable is a consideration. The following proce-
dure shall be adhered to:
1. Remove refrigerant.
2. Purge the circuit with inert gas.
3. Evacuate.
4. Purge again with inert gas.
5. Open the circuit by cutting or brazing.
The refrigerant chare shall be recovered into the correct recovery cylinders. The system shall be “flushed” with OFN to ren-
der the unit safe. This process may need to be repeated several times. Compressed air oxygen shall not be used for this
task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working
pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated
until no refrigerant is within the system. Then the final OFN charge is used, the system shall be vented down to atmosphe-
ric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipe-work are to
take place. Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
13. CHARGING PROCEDURES
In addition to conventional charging procedures, the following requirements shall be followed.
Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall
be as short as possible to minimize the amount of refrigerant contained in them.
Cylinders shall be kept upright.
Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
Label the system when charging is complete (if not already).
Extreme care shall be taken not to overfill the refrigeration system.
Prior to recharging the system, it shall be pressure tested with OFN. They system shall be leak tested on completion of
charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.
14. DECOMMISSIONING
Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its
detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an
oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential
that electrical power is available before the task is commenced.
1. Become familiar with the equipment and its operation.
2. Isolate system electrically.
3. Before attempting the procedure ensure that:
3.1. Mechanical handling equipment is available, if required, for handling refrigerant cylinders.
3.2. All personal protective equipment is available and being used correctly.
3.3. The recovery process is supervised at all times by a competent person.
3.4. Recovery equipment and cylinders conform to the appropriate standards.
4. Pump down refrigerant system, if possible.
5. If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
9 (48)
6. Make sure that cylinder is situated on the scales before recovery takes place.
7. Start the recovery machine and operate in accordance with manufacturer’s instructions.
8. Do not overfill cylinders. (No more than 80 % volume liquid charge).
9. Do not exceed the maximum pressure of the cylinder, even temporarily.
10. When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equip
ment are removed from site promptly and all isolation valves on the equipment are closed off.
11. Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
15. LABELLING
Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated
and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.
16. RECOVERY
When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice
that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrige-
rant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is
available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special
cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off
valves in good working order. Empty recovery cylinders are evacuated and, it possible, cooled before recovery occurs. The
recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand
and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be
available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition.
Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that
any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufac-
turer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and
the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
If compressors or compressor oils are to be removed, ensure that they have been evacuated to
an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation pro-
cess shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body
shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.
10 (48)
TECHNICAL INFORMATION
Temperatures
Room temperature: 18 – 35 °C (cooling)
Measurements
Width: 445 mm
Height: 720 mm
Depth: 375 mm
TYPE PLATE
ENERGY CLASS
11 (48)
UNIT DESCRIPTION
1. Louver
2. Control panel
3. Handle (both sides)
4. Castors
5. Power cable
6. Intake grille
7. Air outlet grille
8. Intake grille
9. Condenser drain
* Open the louver before using the unit
ACCESSORIES INCLUDED
1 set of Exhaust hose, hose inlet and hose outlet
1 set Window slider kit
1 Remote control with battery
Note: all the illustrations in this manual are for explanatory purposes only. Your AC may be slightly different.
12 (48)
INSTALLATION INSTRUCTIONS
2 3
Motor kW 3 x 400 V
1,5 mm22,5 mm24,0 mm26,0 mm2
0,55 246 m
0,75 200 m 333 m
1,10 146 m 244 m 390 m
1,50 109 m 180 m 290 m 435 m
Motor kW 3 x 400 V
Amp
0,55 1,7
0,75 2,2
1,10 3,0
1,50 4,0
Kopplingsschema för djupbrunnspumpar
UNDERHÅLL
Djupbrunnspumpen är i sig själv underhållsfri. Ett
normalt slitage vid pumpning av rent vatten märks
först efter mycket lång tid i drift, dvs pumpen förlorar
kapacitet. Dock skall anläggningens elektriska del un-
derkastas en fortlöpande kontroll av tex nätspänning.
strömförbrukning, manöverorganens elektriska och
mekaniska funktion. fukt, oxidation, brända kontakter
etc. Det är också lämpligt att fortlöpande kontrol-
lera pumpmotorns lindningsvärden. Avvikelser från
föreskrivna lindningsvärden tyder på driftstörningar.
Pumpar som ej är i drift under längre perioder kan utan
problem förbli installerade.
En kortare drift c:a 5–10 minuter per månad förhindrar
att pumpens roterande system fastnar pga. avlagringar.
Ej installerade pumpar skall lagras i sval lokal och verti-
kalt. Före återinstallation, kontrollera motorns fyllning
respektive att det roterande systemet ej fastnat. En rätt
installerad undervattenspump har alla förutsättningar
att ge en lång och säker drift förutsatt att den erhåller:
• rättnätspänning
• rentkalltvatten
• rättstartfrekvens
Det är viktigt för pumpen och anläggningens funktion,
att regelbundet eller minst en gång per år kontrollera
luftmängden i hydroforen. Observera att antalet starter
per timma ej får överskrida 20 st. Den situationen
kan uppstå om hydroforen som används har felaktig
luftmängd. Är anläggningen monterad med membran-
hydrofor skall lufttrycket vara 0,2 bar under pumpens
starttryck. Om tex. starttrycket är 1,5 bar så skall luft-
trycket vara 1,3 bar. Innan pump-anläggningen startas,
kontrollera dessa värden. Vid kontroll av membranhy-
droforens lufttryck skall den alltid vara tom på vatten.
Luftventilen på tanktoppen är av samma typ som finns
på bildäck. Tryckmätning, påfyllning samt avtappning
av luft sker på samma sätt som på ett vanligt bildäck.
Djupbrunnspump: Maximal kabellängd i
meter Avstånd pumpmotor – mätarcentral
Kabeldimensionering enligt tabellerna är vår generella
rekommendation för att garantera djupbrunnspumpens
goda funktion under normala förhållanden. Avvikande
driftsförhållanden som spänningsfall på elnätet, drift
via elverk, varvtalsreglering med frekvensomriktare m
m kan medföra annan dimensionering Lokala stark-
strömsföreskrifter skall beaktas.
REKOMMENDERAD
UNDERVATTENSKABEL
H07RN-F
Djupbrunnspump.
Effekt och märkström
Säkerhetsinstruktion
Installation och drift av roterande maskiner och ap-
parater kan vid icke fackmässig och oriktig hantering
ge upphov till omfattande person- och materialskador.
Bidra till en säker arbetsmiljö samt en ökad livslängd
hos den levererade materielen genom att observera
följande varningssymboler.
Elektrisk anslutning får enbart göras av
behörig elektriker i enlighet med Stark-
strömsföreskrifterna.
Pumpa aldrig andra vätskor än de pumpar-
na är avsedda för. Detta gäller i synnerhet
eldfarliga, explosiva eller frätande vätskor.
Överskrid aldrig maximalvärdena för tryck
och temperatur. Trycksatta rörsystem skall
alltid förses med godkänd säkerhetsventil.
Vid arbete på pumpen (apparaten) skall
alltid arbetsskyddsbrytaren vara frånsla-
gen.
Läs alltid den medlevererade montage-
föreskriften. Om den har förkommit eller
förstörts, kontakta oss.
Tryckkärl monterade i pumpanläggningar
och rörsystem skall vara typgodkända av
ackrediterat kontrollorgan i enlighet med
Arbetsmiljölagen 3 kapitlet , 8 paragra-
fen. Typgodkännandenumret skall vara
angivet på tryckkärlet och leverantören är
på anmodan skyldig att överlämna giltigt
typgodkännandecertifikat.
FARA
FARA
VARNING
VARNING
WARNING!
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in
order to avoid a hazard.
• The appliance shall be installed in accordance with national wiring regulations.
• The appliance shall not be installed in the laundry.
• Make sure the plug is plugged firm and completely into the outlet. It can result in the risk of electric shock or fire.
• Do not plug other appliances into the same outlet, it can result in the risk of electric shock.
• Do not disassemble or modify the appliance or the power cord, it can result in the risk of electric shock or fire. All other
services should be referred to a qualified technician.
• Do not place the power cord or appliance near a heater, radiator, or other heat sources. It can result in the risk of electric
shock or fire.
• This unit is equipped with a cord that has an earthed wire connected to an earthed pin or grounding tab. The plug must
be plugged into a socket that is properly installed and earthed. Do not under any circumstances cut or remove earthed
pin or grounding tab from this plug.
• The unit should be used or store in such a way that it is protected from moisture e.g. condensation, splashed water, etc.
Unplug unit immediately if this occurs.
• Utilize two or more people to lift and install the unit.
• Always grasp the plug when plugging in or unplugging the appliance. Never unplug by pulling on the cord. It can result
in the risk of electrical shock and damage.
• Install the appliance on a sturdy, level floor capable of supporting up to 50 kg. Installation on a weak or unlevel floor can
result in the risk for property damage and personal injury.
2 3
Motor kW 3 x 400 V
1,5 mm22,5 mm24,0 mm26,0 mm2
0,55 246 m
0,75 200 m 333 m
1,10 146 m 244 m 390 m
1,50 109 m 180 m 290 m 435 m
Motor kW 3 x 400 V
Amp
0,55 1,7
0,75 2,2
1,10 3,0
1,50 4,0
Kopplingsschema för djupbrunnspumpar
UNDERHÅLL
Djupbrunnspumpen är i sig själv underhållsfri. Ett
normalt slitage vid pumpning av rent vatten märks
först efter mycket lång tid i drift, dvs pumpen förlorar
kapacitet. Dock skall anläggningens elektriska del un-
derkastas en fortlöpande kontroll av tex nätspänning.
strömförbrukning, manöverorganens elektriska och
mekaniska funktion. fukt, oxidation, brända kontakter
etc. Det är också lämpligt att fortlöpande kontrol-
lera pumpmotorns lindningsvärden. Avvikelser från
föreskrivna lindningsvärden tyder på driftstörningar.
Pumpar som ej är i drift under längre perioder kan utan
problem förbli installerade.
En kortare drift c:a 5–10 minuter per månad förhindrar
att pumpens roterande system fastnar pga. avlagringar.
Ej installerade pumpar skall lagras i sval lokal och verti-
kalt. Före återinstallation, kontrollera motorns fyllning
respektive att det roterande systemet ej fastnat. En rätt
installerad undervattenspump har alla förutsättningar
att ge en lång och säker drift förutsatt att den erhåller:
• rättnätspänning
• rentkalltvatten
• rättstartfrekvens
Det är viktigt för pumpen och anläggningens funktion,
att regelbundet eller minst en gång per år kontrollera
luftmängden i hydroforen. Observera att antalet starter
per timma ej får överskrida 20 st. Den situationen
kan uppstå om hydroforen som används har felaktig
luftmängd. Är anläggningen monterad med membran-
hydrofor skall lufttrycket vara 0,2 bar under pumpens
starttryck. Om tex. starttrycket är 1,5 bar så skall luft-
trycket vara 1,3 bar. Innan pump-anläggningen startas,
kontrollera dessa värden. Vid kontroll av membranhy-
droforens lufttryck skall den alltid vara tom på vatten.
Luftventilen på tanktoppen är av samma typ som finns
på bildäck. Tryckmätning, påfyllning samt avtappning
av luft sker på samma sätt som på ett vanligt bildäck.
Djupbrunnspump: Maximal kabellängd i
meter Avstånd pumpmotor – mätarcentral
Kabeldimensionering enligt tabellerna är vår generella
rekommendation för att garantera djupbrunnspumpens
goda funktion under normala förhållanden. Avvikande
driftsförhållanden som spänningsfall på elnätet, drift
via elverk, varvtalsreglering med frekvensomriktare m
m kan medföra annan dimensionering Lokala stark-
strömsföreskrifter skall beaktas.
REKOMMENDERAD
UNDERVATTENSKABEL
H07RN-F
Djupbrunnspump.
Effekt och märkström
Säkerhetsinstruktion
Installation och drift av roterande maskiner och ap-
parater kan vid icke fackmässig och oriktig hantering
ge upphov till omfattande person- och materialskador.
Bidra till en säker arbetsmiljö samt en ökad livslängd
hos den levererade materielen genom att observera
följande varningssymboler.
Elektrisk anslutning får enbart göras av
behörig elektriker i enlighet med Stark-
strömsföreskrifterna.
Pumpa aldrig andra vätskor än de pumpar-
na är avsedda för. Detta gäller i synnerhet
eldfarliga, explosiva eller frätande vätskor.
Överskrid aldrig maximalvärdena för tryck
och temperatur. Trycksatta rörsystem skall
alltid förses med godkänd säkerhetsventil.
Vid arbete på pumpen (apparaten) skall
alltid arbetsskyddsbrytaren vara frånsla-
gen.
Läs alltid den medlevererade montage-
föreskriften. Om den har förkommit eller
förstörts, kontakta oss.
Tryckkärl monterade i pumpanläggningar
och rörsystem skall vara typgodkända av
ackrediterat kontrollorgan i enlighet med
Arbetsmiljölagen 3 kapitlet , 8 paragra-
fen. Typgodkännandenumret skall vara
angivet på tryckkärlet och leverantören är
på anmodan skyldig att överlämna giltigt
typgodkännandecertifikat.
FARA
FARA
VARNING
VARNING
WARNING!
Before plugging in the appliance into the mains socket, check below. Failure to follow these important safety instructions
absolves the manufacturer of all liability.
• The mains power supply corresponds to the value indicated on the type plate on the back of the appliance.
• The power socket and electrical circuit are adequate for the appliance.
• The mains socket matches the plug. If this is not the case, have the plug replaced.
• The mains socket is adequately earthed.
POSITIONING OF THE UNIT
• The AC should be placed on a firm foundation to minimize noise and vibration.
For safe and secure positioning, place the AC on a smooth, level floor strong
enough to support the AC.
• The AC has casters to aid placement, but it should only be rolled on smooth,
flat surfaces. Use caution when rolling on carpeted surfaces. Use caution and
protect wood floors when rolling the AC over it. Do not attempt to roll the AC
over objects.
• The AC must be placed within reach of a properly rated grounded socket.
• Never place any obstacles around the air inlet or outlet of the AC.
• Allow at least 45 cm of space away from the wall for efficient air conditioning.
• The hose can be extended, but make sure that the hose does not have any
sharp bends or sags.
13 (48)
INSTALLATION
Follow these steps to install the AC:
1. Extend either side of the hose (Fig 1) and screw the hose to the inlet (Fig 2).
2. Extend the other side of the hose and screw it to the hose outlet (Fig 3).
3. lnstall the hose inlet into the unit by sliding on and lock (Fig 4).
4. Affix the hose outlet into the window slider kit and seal. (Fig 5 and 6).
5. Your window slider kit has been designed to fit most standard vertical and horizontal window applications.
The window slider kit can be fastened with screws.
5.1. If the window opening is less than the minimum length of the window slider kit, cut the end short enough to
fit in the window opening. Never cut out the hole in the window slider kit (Fig 7).
INSTALLATION OF WINDOW SLIDER KIT
The window slider kit consists of the following parts:
A) Panel
B) Panel with one hole
C) Panel without hole (not supplied with all models)
D) Screw to lock window kit in place
INSTALLATION:
1. SIide Panel B and C into Panel A.
2. Size to window width. When sizing the window width, be
sure that the window kit assembly is free from gaps and/or
air pockets.
3. Lock the screw into the holes that correspond with the
window width, ensuring that there are no gaps or air pockets
in the window kit assembly after installation.
Fig 5 Fig 6
Fig 1
Fig 2
Fig 3
Fig 7
Fig 4
14 (48)
OPERATING INSTRUCTIONS
IMPORTANT BEFORE USING THE AC
The following information is important to read before using the Altech Portable AC.
2 3
Motor kW 3 x 400 V
1,5 mm22,5 mm24,0 mm26,0 mm2
0,55 246 m
0,75 200 m 333 m
1,10 146 m 244 m 390 m
1,50 109 m 180 m 290 m 435 m
Motor kW 3 x 400 V
Amp
0,55 1,7
0,75 2,2
1,10 3,0
1,50 4,0
Kopplingsschema för djupbrunnspumpar
UNDERHÅLL
Djupbrunnspumpen är i sig själv underhållsfri. Ett
normalt slitage vid pumpning av rent vatten märks
först efter mycket lång tid i drift, dvs pumpen förlorar
kapacitet. Dock skall anläggningens elektriska del un-
derkastas en fortlöpande kontroll av tex nätspänning.
strömförbrukning, manöverorganens elektriska och
mekaniska funktion. fukt, oxidation, brända kontakter
etc. Det är också lämpligt att fortlöpande kontrol-
lera pumpmotorns lindningsvärden. Avvikelser från
föreskrivna lindningsvärden tyder på driftstörningar.
Pumpar som ej är i drift under längre perioder kan utan
problem förbli installerade.
En kortare drift c:a 5–10 minuter per månad förhindrar
att pumpens roterande system fastnar pga. avlagringar.
Ej installerade pumpar skall lagras i sval lokal och verti-
kalt. Före återinstallation, kontrollera motorns fyllning
respektive att det roterande systemet ej fastnat. En rätt
installerad undervattenspump har alla förutsättningar
att ge en lång och säker drift förutsatt att den erhåller:
• rättnätspänning
• rentkalltvatten
• rättstartfrekvens
Det är viktigt för pumpen och anläggningens funktion,
att regelbundet eller minst en gång per år kontrollera
luftmängden i hydroforen. Observera att antalet starter
per timma ej får överskrida 20 st. Den situationen
kan uppstå om hydroforen som används har felaktig
luftmängd. Är anläggningen monterad med membran-
hydrofor skall lufttrycket vara 0,2 bar under pumpens
starttryck. Om tex. starttrycket är 1,5 bar så skall luft-
trycket vara 1,3 bar. Innan pump-anläggningen startas,
kontrollera dessa värden. Vid kontroll av membranhy-
droforens lufttryck skall den alltid vara tom på vatten.
Luftventilen på tanktoppen är av samma typ som finns
på bildäck. Tryckmätning, påfyllning samt avtappning
av luft sker på samma sätt som på ett vanligt bildäck.
Djupbrunnspump: Maximal kabellängd i
meter Avstånd pumpmotor – mätarcentral
Kabeldimensionering enligt tabellerna är vår generella
rekommendation för att garantera djupbrunnspumpens
goda funktion under normala förhållanden. Avvikande
driftsförhållanden som spänningsfall på elnätet, drift
via elverk, varvtalsreglering med frekvensomriktare m
m kan medföra annan dimensionering Lokala stark-
strömsföreskrifter skall beaktas.
REKOMMENDERAD
UNDERVATTENSKABEL
H07RN-F
Djupbrunnspump.
Effekt och märkström
Säkerhetsinstruktion
Installation och drift av roterande maskiner och ap-
parater kan vid icke fackmässig och oriktig hantering
ge upphov till omfattande person- och materialskador.
Bidra till en säker arbetsmiljö samt en ökad livslängd
hos den levererade materielen genom att observera
följande varningssymboler.
Elektrisk anslutning får enbart göras av
behörig elektriker i enlighet med Stark-
strömsföreskrifterna.
Pumpa aldrig andra vätskor än de pumpar-
na är avsedda för. Detta gäller i synnerhet
eldfarliga, explosiva eller frätande vätskor.
Överskrid aldrig maximalvärdena för tryck
och temperatur. Trycksatta rörsystem skall
alltid förses med godkänd säkerhetsventil.
Vid arbete på pumpen (apparaten) skall
alltid arbetsskyddsbrytaren vara frånsla-
gen.
Läs alltid den medlevererade montage-
föreskriften. Om den har förkommit eller
förstörts, kontakta oss.
Tryckkärl monterade i pumpanläggningar
och rörsystem skall vara typgodkända av
ackrediterat kontrollorgan i enlighet med
Arbetsmiljölagen 3 kapitlet , 8 paragra-
fen. Typgodkännandenumret skall vara
angivet på tryckkärlet och leverantören är
på anmodan skyldig att överlämna giltigt
typgodkännandecertifikat.
FARA
FARA
VARNING
VARNING
CAUTION!
• Close the windows and doors in the room to be air conditioned (Fig 21). When installing the AC
semi-permanently, you should leave a door slightly open (as little as 1 cm) to guarantee correct
ventilation.
• Protect the room from direct exposure to the sun by partially closing curtains and/or blinds to
make the AC much more economical to run (Fig 22).
• Never rest objects of any kind on the AC.
• Do not obstruct the air intake and outlet (Fig 23).
• Leave the grilles free.
• Make sure there are no heat sources in the room.
• Never use the AC in very damp rooms (laundries for example ).
• Never use the AC outdoors.
• Make sure the AC is standing on a level surface. If necessary, place the castor locks under the
front wheels.
2 3
Motor kW 3 x 400 V
1,5 mm22,5 mm24,0 mm26,0 mm2
0,55 246 m
0,75 200 m 333 m
1,10 146 m 244 m 390 m
1,50 109 m 180 m 290 m 435 m
Motor kW 3 x 400 V
Amp
0,55 1,7
0,75 2,2
1,10 3,0
1,50 4,0
Kopplingsschema för djupbrunnspumpar
UNDERHÅLL
Djupbrunnspumpen är i sig själv underhållsfri. Ett
normalt slitage vid pumpning av rent vatten märks
först efter mycket lång tid i drift, dvs pumpen förlorar
kapacitet. Dock skall anläggningens elektriska del un-
derkastas en fortlöpande kontroll av tex nätspänning.
strömförbrukning, manöverorganens elektriska och
mekaniska funktion. fukt, oxidation, brända kontakter
etc. Det är också lämpligt att fortlöpande kontrol-
lera pumpmotorns lindningsvärden. Avvikelser från
föreskrivna lindningsvärden tyder på driftstörningar.
Pumpar som ej är i drift under längre perioder kan utan
problem förbli installerade.
En kortare drift c:a 5–10 minuter per månad förhindrar
att pumpens roterande system fastnar pga. avlagringar.
Ej installerade pumpar skall lagras i sval lokal och verti-
kalt. Före återinstallation, kontrollera motorns fyllning
respektive att det roterande systemet ej fastnat. En rätt
installerad undervattenspump har alla förutsättningar
att ge en lång och säker drift förutsatt att den erhåller:
• rättnätspänning
• rentkalltvatten
• rättstartfrekvens
Det är viktigt för pumpen och anläggningens funktion,
att regelbundet eller minst en gång per år kontrollera
luftmängden i hydroforen. Observera att antalet starter
per timma ej får överskrida 20 st. Den situationen
kan uppstå om hydroforen som används har felaktig
luftmängd. Är anläggningen monterad med membran-
hydrofor skall lufttrycket vara 0,2 bar under pumpens
starttryck. Om tex. starttrycket är 1,5 bar så skall luft-
trycket vara 1,3 bar. Innan pump-anläggningen startas,
kontrollera dessa värden. Vid kontroll av membranhy-
droforens lufttryck skall den alltid vara tom på vatten.
Luftventilen på tanktoppen är av samma typ som finns
på bildäck. Tryckmätning, påfyllning samt avtappning
av luft sker på samma sätt som på ett vanligt bildäck.
Djupbrunnspump: Maximal kabellängd i
meter Avstånd pumpmotor – mätarcentral
Kabeldimensionering enligt tabellerna är vår generella
rekommendation för att garantera djupbrunnspumpens
goda funktion under normala förhållanden. Avvikande
driftsförhållanden som spänningsfall på elnätet, drift
via elverk, varvtalsreglering med frekvensomriktare m
m kan medföra annan dimensionering Lokala stark-
strömsföreskrifter skall beaktas.
REKOMMENDERAD
UNDERVATTENSKABEL
H07RN-F
Djupbrunnspump.
Effekt och märkström
Säkerhetsinstruktion
Installation och drift av roterande maskiner och ap-
parater kan vid icke fackmässig och oriktig hantering
ge upphov till omfattande person- och materialskador.
Bidra till en säker arbetsmiljö samt en ökad livslängd
hos den levererade materielen genom att observera
följande varningssymboler.
Elektrisk anslutning får enbart göras av
behörig elektriker i enlighet med Stark-
strömsföreskrifterna.
Pumpa aldrig andra vätskor än de pumpar-
na är avsedda för. Detta gäller i synnerhet
eldfarliga, explosiva eller frätande vätskor.
Överskrid aldrig maximalvärdena för tryck
och temperatur. Trycksatta rörsystem skall
alltid förses med godkänd säkerhetsventil.
Vid arbete på pumpen (apparaten) skall
alltid arbetsskyddsbrytaren vara frånsla-
gen.
Läs alltid den medlevererade montage-
föreskriften. Om den har förkommit eller
förstörts, kontakta oss.
Tryckkärl monterade i pumpanläggningar
och rörsystem skall vara typgodkända av
ackrediterat kontrollorgan i enlighet med
Arbetsmiljölagen 3 kapitlet , 8 paragra-
fen. Typgodkännandenumret skall vara
angivet på tryckkärlet och leverantören är
på anmodan skyldig att överlämna giltigt
typgodkännandecertifikat.
FARA
FARA
VARNING
VARNING
WARNING!
• Children shall not play with the AC.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in
order to avoid a hazard.
• Do not use the AC for functions other than those described in this instruction manual.
• Make sure the plug is plugged firm and completely into the outlet. It can result in the risk of electric shock or fire.
• Do not plug other appliances into the same outlet, it can result in the risk of electric shock.
• Do not disassemble or modify the appliance or the power cord, it can result in the risk of electric shock or fire. All other
services should be referred to a qualified technician.
• Do not place the power cord or appliance near a heater, radiator, or other heat sources. It can result in the risk of electric
shock or fire.
• This unit is equipped with a cord that has an earthed wire connected to an earthed pin or grounding tab. The plug must
be plugged into a socket that is properly installed and earthed. Do not under any circumstances cut or remove earthed
pin or grounding tab from this plug.
• The unit should be used or store in such a way that it is protected from moisture e.g. condensation, splashed water, etc.
Unplug unit immediately if this occurs.
• Always transport your appliance in a vertical position and place on a stable, level surface during use. If the unit is
transported laying on its side it should be stood up and left unplugged for 6 hours.
• Always use the switch on the control panel or remote control to turn the unit off, and do not start or stop operating by
plugging in or unplugging the power cord. It can result in the risk of electric shock.
• Do not touch the buttons on the control panel with your wet and damp fingers.
• Do not use hazardous chemicals to clean or come into contact with the unit. To prevent If the appliance is making
unusual sounds or is emitting smoke or an unusual odor, unplug it immediately.
• Utilize two or more people to lift and install the unit.
• Always grasp the plug when plugging in or unplugging the appliance. Never unplug by pulling on the cord. It can result
in the risk of electrical shock and damage.
15 (48)
CONTROL PANEL
OPERATING AC FROM THE CONTROL PANEL
The control panel is on the top of the AC, it enables you to manage part functions without remote controller, but to fully
exploit its potential, you must use the remote controller.
TURNING THE AC ON:
1. Plug into the mains socket. The AC will turn on in standby mode.
2. Turn on the AC by pressing . The last function agive when the AC was turned off will appear.
3. Turn off the AC by pressing .
4. Wait a few minutes before unplugging.
Important! Never turn the AC off by unplugging from the mains without following above instructions first. By following
the instruction the AC is allowed to perfrom a cycle of checks to verify operation.
16 (48)
CONTROL PANEL OPERATING INSTRUCTIONS
COOL MODE
Cool mode is used for cooling and dehumidify the room. In this mode the exhaust hose needs to be attached.
To set this mode:
1. Press a number of times until the Cool mode (Cool) indicator is lit.
2. Select the target temperature between 18 °C – 32 °C by pressing or until the corresponding value is displayed.
3. Select the required fan speed by pressing . Four speeds are available: High /Medium/ Low / Auto.
The most suitable temperature for the room during the summer varies from 24° to 27 °C. You are recommended, however,
not to set a temperature much below the outdoor temperature. The fan speed difference is more noticeable when the AC
is under Fan mode but may not be noticeable under Cool mode .
FAN MODE
In Fan mode the exhaust hose does not need to be attached.
1. Press a number of times until the Fan mode (Fan) indicator is lit.
2. Select the required fan speed by pressing . Four speeds are available: High /Medium/ Low / Auto. The display
shows as high speed, as medium speed, as low speed.
DRY MODE
Dry mode is used for dehumidifying the room. In this mode the exhaust hose needs to be attached.
To set this mode:
1. Press a number of times until the display shows . Note: In this mode, fan speed is selected automatically by
the AC and can not be set manually.
TIMER MODE
Timer mode is used for delaying the AC startup or shutdown. This avoids wasting electricity by optimizing operating periods.
Programming startup
1. Turn on the AC. Choose mode, for example Cool mode, 24 °C, high fan speed. Turn off the AC.
2. Press . The Timer mode indicator and number of hours on the display starts to flash.
3. Press or to set the number of hours delay before the AC startup. The Timer mode can be set in intervals of 0.5
hours up to 10 hours, or intervals of 1 hour up to 24 hours.
4. A few seconds after set, the setting is memorized, the Timer mode indicator is lit and the display shows that the AC is
in standby.
5. To end Timer mode: press again or . The symbol disappears from the display.
17 (48)
Programming shutdown
1. When the AC is started press . The Timer mode indicator and number of hours on the display starts to flash.
2. Press or to set the number of hours delay before the AC shut downs. The Timer mode can be set in intervals of
0.5 hours up to 10 hours, or intervals of 1 hour up to 24 hours.
3. A few seconds after set, the setting is memorized, the Timer mode indicator is lit and the display shows the current
mode. At the end of the set time the unit automatically turns to standby mode.
4. To end Timer mode: press again or . The symbol disappears from the display.
SELF-DIAGNOSIS
The AC has a self diagnosis system to identify a number of malfunctions. Error messages are shown on the display..
Fault code Solution
Low temperature (frost prevention)
The AC is fitted with a frost protection device to avoid
excessive formation of ice.
The AC starts up again automatically when the defrosting
process is completed.
Probe failure (sensor damaged)
lf this is displayed, contact your local authorised service
centre.
Full tank (safety tank full)
Empty the internal safety tank, following the instructions in
the "End of season operations" paragraph.
18 (48)
OPERATING INSTRUCTION FOR REMOTE CONTROL
• Point the remote control at the receiver on the AC.
• The remote control must be no more than 7 meters away from the AC (without obstacles between the remote control and
the receiver).
• The remote control must be handled with extreme care. Do not drop it or expose it to direct sunlight or sources of heat.
If the remote control do not work, try to take out the battery, and put it back.
INSERTING OR REPLACING THE BATTERIES
Så här sätter du i eller byter batterier:
1. Remove the cover on the rear of the remote control.
2. lnsert two "AAA" 1.5V batteries in the correct positioN (see instructions
inside the battery compartment).
3. Put back the cover-
Note!
lf the remote control unit is replaced or disposed of, the batteries must be removed and discarded in accordance with
current legislation as they are harmful to the environment.
Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc) or rechargeable (nickel-cadmium) batteries.
Do not dispose of batteries in fire. Batteries may explode or leak.
lf the remote control is not be used fora certain length of time, remove the batteries
19 (48)
COOL MODE
Cool mode is used for cooling and dehumidify the room. In this mode the exhaust hose needs to be attached.
Så här ställer du in läget:
1. Press a number of times until the symbol appears next to the symbol.
2. Select the target temperature between 18 – 32 °C by pressing or until the corresponding value is displayed.
3. Select the required fan speed by pressing . Four speeds are available: High /Medium/ Low / Auto.
.
The most suitable temperature for the room during the summer varies from 24 to 27 °C. You are recommended, however,
not to set a temperature much below the outdoor temperature. The fan speed difference is more noticeable when the AC
is under Fan mode but may not be noticeable under Cool mode.
FAN MODE
In Fan mode the exhaust hose does not need to be attached.
1. Press a number of times until the symbol appears next to the symbol.
2. Select the required fan speed by pressing . Four speeds are available: High /Medium/
Low / Auto.
DRY MODE
Dry mode is used for dehumidifying the room. In this mode the exhaust hose needs to be attached.
1. Press a number of times until the symbol appears next to the symbol. The display
on the AC shows . Note: In this mode, fan speed is selected automatically by the AC and
can not be set manually.
AUTO MODE
Auto mode is used for the AC to automatically choose to operate in Cool mode or Fan mode.
To set this mode:
1. Press a number of times until the symbol appears next to the symbol. The display
shows .
2. Select the required fan speed by pressing . Four speeds are available: High / Medium /
Low / Auto.
The AC is operating in Fan mode when the temperature is under 23 °C and operating in Cool mode when the temperature
is over 23 °C.
Display on the control panel:
The AC is in Auto mode when the display will be running circulating.
20 (48)
SLEEP MODE
When you choose Sleep mode, the screen will reduce the brightness. Sleep mode maintains the
room at optimum temperature without excessive fluctuations in either temperature or humidity
with silent operation. Fan speed is always at Low, while room temperature and humidity vary
gradually to ensure the most comfortable. In this mode the exhaust hose needs to be attached.
To set this mode:
1. Set the Cool mode by following earlier instructions.
2. Press and the symbol appears under the symbol.
When in Cool mode, the selected temperature will increase by 1 °C per hour in a 2 hour period. This new temperature is
maintained for the next 6 hours. Then the AC turns off.
You can turn Sleep mode off at any time by pressing any of the "Sleep", "Mode" or "Fan speed" buttons. Sleep mode
cannot be set to Fan- or Dehumidifier mode.
TIMER MODE
Timer mode mode is used for delaying the AC startup or shutdown. This avoids wasting electricity by optimizing operating
periods.
Programming startup
1. Turn on the AC. Choose mode, for example Cool mode, 24 °C, high fan speed. Turn off the
AC.
2. Press twice. The display will show 0.5 – 24 hours and the symbol appears next to the
symbol and “h” symbol is flashing.
3. Press or several times until the corresponding time is displayed. Press again.
Timer mode is activated, the symbol appears next to the symbol and the time is
shown on the display.
4. To end Timer mode: press again or . The symbol next to the symbol
disappears from the display.
Programming shutdown
1. When the AC is started, press . The display will show 0.5 – 24 hours and the symbol
appears next to the symbol and the “h” symbol is flashing.
2. Press or several times until the corresponding time is displayed. Press again.
Timer mode is activated, the symbol appears next to the symbol and the time is
shown on the display.
3. To end Timer mode: press again or . The symbol next to the symbol disappears
from the display.
CHANGE THE UNIT OF TEMPERATURE
When the AC is in Cool mode, press °C/°F, to change the unit of temperature between Celsius and Farenheit.
For example:
Before change the display looks like Fig 1, in Cool mode.
After change the display looks like Fig 2, in Cool mode.
Fig 1
Fig 2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Altech ALT-PAC3200C Användarmanual

Typ
Användarmanual

på andra språk